Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor

Open access
Christiansen, Mark P., Garg, Satish K., Brazg, Ronald, Bode, Bruce W., Bailey, Timothy S., Slover, Robert H., Sullivan, Ashley, Huang, Suiying, Shin, John, Lee, Scott W., Kaufman, Francine R. · 2017 · Diabetes Technology & Therapeutics
Cited by 151

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: This study evaluated the accuracy and performance of a fourth-generation subcutaneous glucose sensor (Guardian™ Sensor 3) in the abdomen and arm. Methods: Eighty-eight subjects (14–75 years of age, mean ± standard deviation [SD] of 42.0 ± 19.1 years) with type 1 or type 2 diabetes participated in the study. Subjects wore two sensors in the abdomen that were paired with either a MiniMed™ 640G insulin pump, or an iPhone® or iPod® touch® running a glucose monitoring mobile application (Guardian Connect system) and a third sensor in the arm, which was connected to a glucose sensor recorder (GSR). Subjects were also asked to undergo in-clinic visits of 12–14 h on study days 1, 3, and 7 for frequent blood glucose sample testing using a Yellow Springs Instrument (YSI) reference. Results: The overall mean absolute relative difference (MARD ± SD) between abdomen sensor glucose (SG) and YSI reference values was 9.6% ± 9.0% and 9.4% ± 9.8% for the MiniMed 640G insulin pump and Guardian Connect system, respectively; and 8.7% ± 8.0% between arm SG and YSI reference values. The percentage of SG values within 20% agreement of the YSI reference value (for YSI >80 mg/dL) was 90.7% with the MiniMed 640G insulin pump, 91.8% with the Guardian Connect system, and 93.1% for GSR-connected arm sensors. Mean functional sensor life, when calibrating 3–4 times/day, was 145.9 ± 39.3 h for sensors paired with the MiniMed 640G insulin pump, 146.1 ± 41.6 h for sensors paired with the Guardian Connect system, and 147.6 ± 40.4 h for sensors connected to the GSR. Responses to survey questions regarding sensor comfort and ease of use were favorable. Conclusions: The Guardian Sensor 3 glucose sensor, whether located in abdomen or the arm, provided accurate glucose readings when compared with the YSI reference and demonstrated functional life commensurate with the intended 7-day use. ClinicalTrials.gov: NCT02246582

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2017.0087

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Research works printed but not linked: 16

  1. 10.1089/dia.2013.0078 · DOI
  2. 10.1111/j.1464-5491.2011.03256.x · DOI · Paper page
  3. 10.2337/dc09-0750 · DOI · Paper page
  4. 10.1089/dia.2011.0080 · DOI
  5. 10.1089/dia.2008.0032 · DOI · Paper page
  6. 10.1111/dme.12079 · DOI
  7. 10.1089/dia.2016.0288 · DOI
  8. 10.1111/dme.12661 · DOI · Paper page
  9. 10.2337/dc09-0889 · DOI · Paper page
  10. 10.1089/dia.2011.0199 · DOI · Paper page
  11. 10.1089/dia.2013.0222 · DOI
  12. 10.1111/j.1464-5491.2005.01672.x · DOI · Paper page
  13. 10.1089/dia.2013.0077 · DOI
  14. 10.1089/dia.2014.0272 · DOI · Paper page
  15. 10.2337/dc06-1602 · DOI · Paper page
  16. 10.1089/dia.2004.6.790 · DOI

Cited by

See all 151

Metadata

Authors
Christiansen, M. P., Garg, S. K., Brazg, R., Bode, B. W., Bailey, T. S., Slover, R. H., Sullivan, A., Huang, S., Shin, J., Lee, S. W., & Kaufman, F. R.
Venue
Diabetes Technology & Therapeutics
Published
2017-08
Volume
19
Issue
8
Pages
446-456
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2734661081
Cited by
151
References
8
FWCI
9.65
Type
journal article
Language
en
Open access
green
Licence
www.liebertpub.com/nv/resources-tools/text-and-data-mining-policy/121/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor. https://app.cochat.ai/papers/10.1089/dia.2017.0087
The paper
Christiansen, M. P., Garg, S. K., Brazg, R., Bode, B. W., Bailey, T. S., Slover, R. H., Sullivan, A., Huang, S., Shin, J., Lee, S. W., & Kaufman, F. R. (2017). Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2017.0087

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.