CoChat

Flash Glucose Measurements in Children with Type 1 Diabetes in Real-Life Settings: To Trust or Not to Trust?

Szadkowska, Agnieszka, Gawrecki, Andrzej, Michalak, Arkadiusz, Zozulińska-Ziółkiewicz, Dorota, Fendler, Wojciech, Młynarski, Wojciech · 2018 · Diabetes Technology & Therapeutics
Cited by 43

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND AIMS: To evaluate the clinical accuracy of a flash glucose monitoring device FreeStyle Libre (FSL) among children with type 1 diabetes in real-world settings during a summer camp. MATERIALS AND METHODS: During a summer camp, children with type 1 diabetes (n = 79, aged 8-18 years) were provided with FSLs for 12 days. On days 3, 7, and 11 of the study, they underwent supervised glucose testing at 8 timepoints. Glycemia was estimated by using FSL and measured with a personal glucometer within a period of 2 min. The glucose trend arrows were recorded. RESULTS: The study was completed by 78 children (median: age 12.8 years, diabetes duration 5.8 years, HbA1c 58.5 mmol/mol). Mean absolute relative difference (MARD) between the FSL and the glucometer was 13.5% ± 12.9%. FSL was the most accurate in stable glycemic conditions: MARD 11.4% ± 10.4%, less accurate when glycemia was falling >2 mg/(dL·min) [0.111 mmol/(L·min)-MARD 22.6% ± 18.6%; P < 0.001 vs. stable conditions] and when the device could not determine the glucose trends (16.5% ± 16.3%, P = 0.01 vs. stable conditions). The FSL demonstrated lower accuracy during the day than the night [MARD 14.9% ± 14% vs. 11.2% ± 10.6%, P < 0.0001]. Out of 1655 data pairs of glucometer and FSL, using the Surveillance Error Grid methodology we determined that 80.36% of FSL readings were associated with no clinical risk, 18.73% with slight risk and only one high-risk measurement was detected. CONCLUSION: FSL is accurate in children, but its accuracy depends on the glucose trend. Results flagged by the rapid fall flag and "trend undetermined" should be verified by blood glucose measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2017.0287

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 43

Metadata

Authors
Szadkowska, A., Gawrecki, A., Michalak, A., Zozulińska-Ziółkiewicz, D., Fendler, W., & Młynarski, W.
Venue
Diabetes Technology & Therapeutics
Published
2018-01
Volume
20
Issue
1
Pages
17-24
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2772973003
Cited by
43
References
8
FWCI
4.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flash Glucose Measurements in Children with Type 1 Diabetes in Real-Life Settings: To Trust or Not to Trust? https://app.cochat.ai/papers/10.1089/dia.2017.0287
The paper
Szadkowska, A., Gawrecki, A., Michalak, A., Zozulińska-Ziółkiewicz, D., Fendler, W., & Młynarski, W. (2018). Flash Glucose Measurements in Children with Type 1 Diabetes in Real-Life Settings: To Trust or Not to Trust? Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2017.0287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.