CoChat

Cost-Effectiveness Analysis of the MiniMed 670G Hybrid Closed-Loop System Versus Continuous Subcutaneous Insulin Infusion for Treatment of Type 1 Diabetes

Jendle, Johan, Pöhlmann, Johannes, de Portu, Simona, Smith-Palmer, Jayne, Roze, Stéphane · 2019 · Diabetes Technology & Therapeutics
Cited by 52

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Hybrid closed-loop (HCL) systems combine continuous glucose monitoring with continuous subcutaneous insulin infusion (CSII) to continuously self-adjust basal insulin delivery. Relative to CSII, HCL improves glycemic control and reduces the risk of hypoglycemia but has higher acquisition costs. The aim of this analysis was to assess the cost-effectiveness of the MiniMed™ 670G HCL system versus CSII in people with type 1 diabetes (T1D) in Sweden. METHODS: Cost-effectiveness analysis, from a societal perspective, was performed over patient lifetimes using the IQVIA CORE Diabetes Model. Clinical data were sourced from a study comparing the MiniMed 670G system with CSII in people with T1D. Cost data, expressed in 2018 Swedish krona (SEK), were obtained from Swedish reference prices and published literature. RESULTS: The MiniMed 670G system was associated with a quality-adjusted life-year (QALY) gain of 1.90 but higher overall costs versus CSII, leading to an incremental cost-effectiveness ratio (ICER) of SEK 164,236 per QALY gained. Use of the HCL system resulted in a lower cumulative incidence of diabetes-related complications. Higher HCL system acquisition costs were partially offset by reduced complication costs and productivity losses. In people with T1D poorly controlled at baseline, the MiniMed 670G system was associated with 2.25 incremental QALYs versus CSII, yielding an ICER of SEK 15,830 per QALY gained. CONCLUSIONS: The MiniMed 670G system was associated with clinical benefits and quality-of-life improvements in people with T1D relative to CSII. At a willingness-to-pay threshold of SEK 300,000 per QALY gained, this HCL system likely represents a cost-effective treatment option for people with T1D in Sweden.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2018.0328

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 52

Metadata

Authors
Jendle, J., Pöhlmann, J., de Portu, S., Smith-Palmer, J., & Roze, S.
Venue
Diabetes Technology & Therapeutics
Published
2019-03
Volume
21
Issue
3
Pages
110-118
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2917355348
Cited by
52
References
15
FWCI
5.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cost-Effectiveness Analysis of the MiniMed 670G Hybrid Closed-Loop System Versus Continuous Subcutaneous Insulin Infusion for Treatment of Type 1 Diabetes. https://app.cochat.ai/papers/10.1089/dia.2018.0328
The paper
Jendle, J., Pöhlmann, J., de Portu, S., Smith-Palmer, J., & Roze, S. (2019). Cost-Effectiveness Analysis of the MiniMed 670G Hybrid Closed-Loop System Versus Continuous Subcutaneous Insulin Infusion for Treatment of Type 1 Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2018.0328

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.