The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Time in Range Is Associated with Carotid Intima-Media Thickness in Type 2 Diabetes
Abstract
Background: Time in range (TIR) is an emerging metric of glycemic control and is reported to be associated with microvascular complications of diabetes. We sought to investigate the association of TIR obtained from continuous glucose monitoring (CGM) with carotid intima-media thickness (CIMT) as a surrogate marker of cardiovascular disease (CVD). Methods: Data from 2215 patients with type 2 diabetes were cross-sectionally analyzed. TIR of 3.9–10.0 mmol/L was evaluated with CGM. CIMT was measured using high-resolution B-mode ultrasonography and abnormal CIMT was defined as a mean CIMT ≥1.0 mm. Logistic regression models were used to examine the independent association of TIR with CIMT. Results: Compared with patients with normal CIMT, those with abnormal CIMT had significantly lower TIR ( P < 0.001). The prevalence of abnormal CIMT progressively decreased across the categories of increasing TIR ( P for trend <0.001). In a fully adjusted model controlling for traditional risk factor of CVD, each 10% increase in TIR was associated with 6.4% lower risk of abnormal CIMT. Stratifying the data by sex revealed that TIR was significantly associated with CIMT in males but not in females. In a subset of patients ( n = 612) with complete data on diabetic retinopathy and albuminuria, we found that the relationship between TIR and CIMT remained to be significant, regardless of the status of microvascular complications. Conclusions: TIR is associated with CIMT in a large sample of patients with type 2 diabetes, suggesting a link between TIR and macrovascular disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
Diabetes Mellitus, Fasting Glucose, and Risk of Cause-Specific Death
The Emerging Risk Factors Collaboration (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1008862 · Cited by 2,726
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationChambless, L. E., Heiss, G., Folsom, A. R., Rosamond, W., Szklo, M., Sharrett, A. R., & Clegg, L. X. (1997) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009302 · Cited by 1,990
Glycated hemoglobin, diabetes, and cardiovascular risk in nondiabetic adults
Selvin, E., Steffes, M. W., Zhu, H., Matsushita, K., Wagenknecht, L., Pankow, J., Coresh, J., & Brancati, F. L. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0908359 · Cited by 1,544
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., Kollman, C., Li, Z., Brown, A. S., & Close, K. L. (2019) · Diabetes Care · doi:10.2337/dc18-1444 · Cited by 793
Lu, J., Ma, X., Zhou, J., Zhang, L., Mo, Y., Ying, L., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1131 · Cited by 517
Self-citationThe relationships between time in range, hyperglycemia metrics, and HbA1c
Beck, R. W., Bergenstal, R. M., Cheng, P., Kollman, C., Carlson, A. L., Johnson, M. L., & Rodbard, D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818822496 · Cited by 479
The fallacy of average: how using HbA1c alone to assess glycemic control can be misleading
Beck, R. W., Connor, C. G., Mullen, D. M., Wesley, D. M., & Bergenstal, R. M. (2017) · Diabetes Care · doi:10.2337/dc17-0636 · Cited by 477
Cited by
6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
Continuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
6. Glycemic Targets: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684
Yapanis, M., James, S., Craig, M. E., O’Neal, D., & Ekinci, E. I. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac034 · Cited by 291
Metadata
- Authors
- Lu, J., Ma, X., Shen, Y., Wu, Q., Wang, R., Zhang, L., Mo, Y., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., Jia, W., & Zhou, J.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2020-02-01
- Volume
- 22
- Issue
- 2
- Pages
- 72-78
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2974891484
- Cited by
- 227
- References
- 11
- FWCI
- 20.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Time in Range Is Associated with Carotid Intima-Media Thickness in Type 2 Diabetes. https://app.cochat.ai/papers/10.1089/dia.2019.0251
- The paper
- Lu, J., Ma, X., Shen, Y., Wu, Q., Wang, R., Zhang, L., Mo, Y., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., Jia, W., & Zhou, J. (2020). Time in Range Is Associated with Carotid Intima-Media Thickness in Type 2 Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2019.0251
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.