Prospective Analysis of the Impact of Commercialized Hybrid Closed-Loop System on Glycemic Control, Glycemic Variability, and Patient-Related Outcomes in Children and Adults: A Focus on Superiority Over Predictive Low-Glucose Suspend Technology
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background: Automatization of insulin delivery by closed-loop systems represents a major step in type 1 diabetes management. The aim of this study was to analyze the effect of the commercialized hybrid closed-loop system, the MiniMed 670G system, on glycemic control, glycemic variability, and patient satisfaction. Methods: A prospective study, including type 1 diabetes patients consecutively starting on the 670G system in one adult and two pediatric hospitals, was performed. Baseline and 3-month visits were documented. Two weeks of data from the system were downloaded. Glycemic variability measures were calculated. Adults and adolescents completed a set of questionnaires (Gold and Clarke scores, Hypoglycemia Fear Survey, Diabetes Quality of Life [DQoL], Diabetes Treatment Satisfaction [DTS], Diabetes Distress Scale, Pittsburgh Sleep Quality Index). Results: Fifty-eight patients were included (age: 28 ± 15 years [7–63], <18 years old: 38% [ n = 22], 59% [ n = 34] females, previous use of SAP-PLGS [predictive low-glucose suspend]: 60% [ n = 35]). HbA1c was reduced from 57 ± 10 to 53 ± 7 mmol/L (7.4% ± 0.9% to 7.0% ± 0.6%) ( P < 0.001) and time in range 70–180 mg/dL was increased from 63.0% ± 11.4% to 72.7% ± 8.7% ( P < 0.001). In patients with high baseline hypoglycemia risk, time <54 and <70 mg/dL were reduced from 0.9% ± 1.1% to 0.45% ± 0.7% ( P = 0.021) and from 3.3% ± 2.8% to 2.1% ± 2.1% ( P = 0.019), respectively. Glycemic variability measures improved. Time in auto mode was 85% ± 17%, the number of auto mode exits was 0.6 ± 0.3 per day, and the number of alarms was 8.5 ± 3.7 per day. Fear of hypoglycemia, DQoL, DTS, and diabetes distress improved, while the percentage of patients with poor sleep quality was reduced. The discontinuation rate was 3%. Conclusion: The commercialized hybrid closed-loop system improves glycemic control and glycemic variability in children and adults, reducing the burden of living with type 1 diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“21 Nevertheless, similarly to previous reports with other hybrid closed-loop systems, 22 in the subgroup of patients with high hypoglycemia frequency and risk, from our cohort, the frequency of hypo-glycemia was reduced and HbA1c also was reduced.”
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · cited 1×
“8,12 We showed that in patients with diabetes already considered to be stable (CV 36%), 20 a further reduction in glycemic variability could be achieved.”
Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes
Bergenstal, R. M., Garg, S., Weinzimer, S. A., Buckingham, B. A., Bode, B. W., Tamborlane, W. V., & Kaufman, F. R. (2016) · JAMA · doi:10.1001/jama.2016.11708 · Cited by 644 · cited 3×
“8,9,11,12,14 The experience with the 670G system in the United States comes from patients previously using MDIs with or without FIG.”
Garg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585 · cited 8×
“8,9,12,13 Also, this benefit was highly related to baseline glycemic control, being the patients with the highest baseline HbA1c who obtained a greater benefit.”
InfluentialWeisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463
Bekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
One year clinical experience of the first commercial hybrid closed-loop system
Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019) · Diabetes Care · doi:10.2337/dc19-0855 · Cited by 215
Anderson, S. M., Buckingham, B. A., Breton, M. D., Robic, J. L., Barnett, C. L., Wakeman, C. A., Oliveri, M. C., Brown, S. A., Ly, T. T., Clinton, P. K., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0018 · Cited by 68 · cited 1×
“21 Nevertheless, similarly to previous reports with other hybrid closed-loop systems, 22 in the subgroup of patients with high hypoglycemia frequency and risk, from our cohort, the frequency of hypo-glycemia was reduced and HbA1c also was reduced.”
Beato-Víbora, P. I., Quirós-López, C., Lázaro-Martín, L., Martín-Frías, M., Barrio-Castellanos, R., Gil-Poch, E., Arroyo-Díez, F. J., & Giménez-Álvarez, M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0199 · Cited by 60
Self-citation
Cited by
A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455
Carlson, A. L., Sherr, J. L., Shulman, D. I., Garg, S. K., Pop-Busui, R., Bode, B. W., Lilenquist, D. R., Brazg, R. L., Kaiserman, K. B., Kipnes, M. S., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0319 · Cited by 230
ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
A Systematic Review of Commercial Hybrid Closed-Loop Automated Insulin Delivery Systems
Peacock, S., Frizelle, I., & Hussain, S. (2023) · Diabetes Therapy · doi:10.1007/s13300-023-01394-5 · Cited by 122
Speight, J., Choudhary, P., Wilmot, E. G., Hendrieckx, C., Forde, H., Cheung, W. Y., Crabtree, T., Millar, B., Traviss‐Turner, G., Hill, A., et al. (2023) · Diabetic Medicine · doi:10.1111/dme.14944 · Cited by 92
Metadata
- Authors
- Beato-Víbora, P. I., Gallego-Gamero, F., Lázaro-Martín, L., Romero-Pérez, M. D. M., & Arroyo-Díez, F. J.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2020-12-01
- Volume
- 22
- Issue
- 12
- Pages
- 912-919
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2995689063
- Cited by
- 66
- References
- 9
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.