Performance of the Dexcom G6 Continuous Glucose Monitoring System in Pregnant Women with Diabetes
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background: The aim of this study was to determine the performance of the Dexcom G6 continuous glucose monitoring (CGM) system across three sensor wear sites in pregnant women with diabetes in the second or third trimesters. Methods: Participants with type 1 (T1D), type 2 (T2D), or gestational (GDM) diabetes mellitus were enrolled at three sites. Each wore two G6 sensors on the abdomen, upper buttock, and/or posterior upper arm for 10 days and underwent a 6-h clinic session between days 3 and 7 of sensor wear, during which YSI reference blood glucose values were obtained every 30 min. No intentional glucose manipulations were performed. Accuracy metrics included the proportion of CGM values that were within ±20% of paired reference values >100 mg/dL or ±20 mg/dL of YSI values ≤100 mg/dL (hereafter referred to as %20/20), as well as the analogous %15/15, %30/30, and %40/40. The mean absolute relative difference (MARD) between CGM-YSI pairs was also calculated. Results: Thirty-two participants with T1D ( n = 20), T2D ( n = 3), or GDM ( n = 9) were enrolled: 19 were in the second trimester and 13 were in the third trimester of pregnancy. Compared with the reference, 92.5% of CGM values were within ±20%/20 mg/dL. The overall MARD and that of sensors worn on the abdomen, upper buttock, and posterior upper arm was 10.3%, 11.5%, 11.2%, and 8.7%, respectively. There were no device-related adverse events. Skin reactions at the insertion sites were absent or minor. Conclusions: The Dexcom G6 CGM system is accurate and safe in pregnant women with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hyperglycemia and adverse pregnancy outcomes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0707943 · Cited by 5,563
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
ACOG Practice Bulletin No. 190: Gestational Diabetes Mellitus
(2018) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002501 · Cited by 1,820
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
Self-citationSuhonen, L., Hiilesmaa, V., & Teramo, K. (2000) · Diabetologia · doi:10.1007/s001250050010 · Cited by 302
Inkster, M. E., Fahey, T. P., Donnan, P. T., Leese, G. P., Mires, G. J., & Murphy, D. J. (2006) · BMC Pregnancy and Childbirth · doi:10.1186/1471-2393-6-30 · Cited by 233
García-Patterson, A., Gich, I., Amini, S. B., Catalano, P. M., de Leiva, A., & Corcoy, R. (2010) · Diabetologia · doi:10.1007/s00125-009-1633-z · Cited by 220
ROSENN, B., MIODOVNIK, M., HOLCBERG, G., KHOURY, J., & SIDDIQI, T. (1995) · Obstetrics & Gynecology · doi:10.1016/0029-7844(94)00415-a · Cited by 161
Evers, I. M., ter Braak, E. W. M. T., de Valk, H. W., van der Schoot, B., Janssen, N., & Visser, G. H. A. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.554 · Cited by 152
Chen, R., Yogev, Y., Ben-Haroush, A., Jovanovic, L., Hod, M., & Phillip, M. (2003) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/jmf.14.4.256.260 · Cited by 101
Cited by
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Accuracy and Safety of Dexcom G7 Continuous Glucose Monitoring in Adults with Diabetes
Garg, S. K., Kipnes, M., Castorino, K., Bailey, T. S., Akturk, H. K., Welsh, J. B., Christiansen, M. P., Balo, A. K., Brown, S. A., Reid, J. L., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0011 · Cited by 179
Self-citationTime in range in pregnancy: is there a role?
Wyckoff, J. A., & Brown, F. M. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0103 · Cited by 39
Zheng, Y., Zhan, Z., Chen, Q., Chen, J., Luo, J., Cai, J., Zhou, Y., Chen, K., & Xie, W. (2024) · Advanced Science · doi:10.1002/advs.202405681 · Cited by 38
Metadata
- Authors
- Castorino, K., Polsky, S., O'Malley, G., Levister, C., Nelson, K., Farfan, C., Brackett, S., Puhr, S., & Levy, C. J.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2020-12-01
- Volume
- 22
- Issue
- 12
- Pages
- 943-947
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W3018238868
- Cited by
- 79
- References
- 12
- FWCI
- 6.69
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of the Dexcom G6 Continuous Glucose Monitoring System in Pregnant Women with Diabetes. https://app.cochat.ai/papers/10.1089/dia.2020.0085
- The paper
- Castorino, K., Polsky, S., O'Malley, G., Levister, C., Nelson, K., Farfan, C., Brackett, S., Puhr, S., & Levy, C. J. (2020). Performance of the Dexcom G6 Continuous Glucose Monitoring System in Pregnant Women with Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2020.0085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.