HbA1c and Glucose Management Indicator Discordance: A Real-World Analysis
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background: There can be marked discordance between laboratory and estimated (using the glucose management indicator (GMI)) HbA1c from continuous glucose monitoring (CGM). This may cause errors in diabetes management. This study evaluates discordance between laboratory and CGM-estimated HbA1c. Methods: We performed a retrospective review of patients with diabetes who use CGM. The patients were seen at the University of Washington (UW) Diabetes Care Center from 2012-2019. We used UW’s Institute of Translational Health Sciences to extract eligible encounters from the electronic medical record. We required that patients use CGM and that HbA1c and sensor data be obtained fewer than four weeks apart. There were no exclusion criteria. We calculated HbA1c-GMI discordance for each subject and assessed for any impact of comorbidities. We defined HbA1c-GMI discordance as absolute difference between laboratory and estimated HbA1c. Findings: This study included 641 separate office encounters. Ninety-one percent of patients had type 1 diabetes. Most patients had diabetes for greater than 20 years. The mean duration of CGM wear was 24·5 ± 8 days. Only 11% of patients had HbA1c-GMI discordance < 0.1%, but 50% and 22% had differences > 0·5% and > 1%. There was increased discordance with advanced chronic kidney disease (CKD) (GFR < 60). Interpretation: We found substantial discordance between laboratory and estimated HbA1c in a real-world setting. Clinicians need be aware that HbA1c may not as accurately reflect mean glucose as previously appreciated. Funding Statement: Dr. Perlman’s work was supported by a University of Washington Housestaff Association resident research grant. Declaration of Interests: Dualities: JEP: none; TAG: none; BM: none; JM: none; IBH: research grants from Medtronic Diabetes and Insulet; consulting with Abbott Diabetes Care, Bigfoot, and Roche. Ethics Approval Statement: This study was approved by the University of Washington IRB Human Subjects Division.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 1×
“That said, CGM has become a standard of care in many settings, so it is critical that we find ways to integrate these metrics (including time in range [TIR], time above range [TAR], and GMI) into both clinical care and research.(15) A recent publication demonstrated linear relationships between TIR and TAR and mean gl…”
BackgroundSelf-citationInternational consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · cited 2×
“Before development of GMI, an international consensus group concluded that eA1C should be a core measurement recommended for inclusion on standard CGM reports.(6) These experts felt eA1C was most useful when it showed discrepancies between estimated and measured”
BackgroundSelf-citationTranslating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., Kollman, C., Li, Z., Brown, A. S., & Close, K. L. (2019) · Diabetes Care · doi:10.2337/dc18-1444 · Cited by 793 · cited 1×
“computed TIR from Diabetes Control and Complications Trial fingerstick data and showed a strong correlation with risk of microvascular complications.(17) Lu et al.”
MethodGlucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring
Bergenstal, R. M., Beck, R. W., Close, K. L., Grunberger, G., Sacks, D. B., Kowalski, A., Brown, A. S., Heinemann, L., Aleppo, G., Ryan, D. B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1581 · Cited by 684
Lu, J., Ma, X., Zhou, J., Zhang, L., Mo, Y., Ying, L., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1131 · Cited by 517 · cited 2×
“Beck et al. computed TIR from Diabetes Control and Complications Trial fingerstick data and showed a strong correlation with risk of microvascular complications.17 Lu et al. and Li et al. determined that decreased TIR and increased glycemic variation is linked to retinopathy and peripheral neuropathy in T2DM.18,19 In…”
BackgroundAssessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
Aleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., et al. (2017) · Diabetes Care · doi:10.2337/dc16-2482 · Cited by 329
Self-citationRacial Differences in the Relationship of Glucose Concentrations and Hemoglobin A1c Levels
Bergenstal, R. M., Gal, R. L., Connor, C. G., Gubitosi-Klug, R., Kruger, D., Olson, B. A., Willi, S. M., Aleppo, G., Weinstock, R. S., Wood, J., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2596 · Cited by 306 · cited 1×
“Previous research suggests that HbA1c is higher in African Americans for any given mean glucose (larger discordance).(12) Our patients were predominantly Caucasian (1% African American) thus negating this potential biological explanation.”
BackgroundClinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168 · cited 1×
“This sensor has a published MARD (mean absolute relative difference) of 9%.(13) Another 7% used a later model of this device (Dexcom G6) that has an identical MARD.”
MethodRodbard, D. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0440 · Cited by 75
Cited by
Continuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
Self-citationGrunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
de Bock, M., Codner, E., Craig, M. E., Huynh, T., Maahs, D. M., Mahmud, F. H., Marcovecchio, L., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13455 · Cited by 254
The Growing Role of Technology in the Care of Older Adults With Diabetes
Huang, E. S., Sinclair, A., Conlin, P. R., Cukierman-Yaffe, T., Hirsch, I. B., Huisingh-Scheetz, M., Kahkoska, A. R., Laffel, L., Lee, A. K., Lee, S., et al. (2023) · Diabetes Care · doi:10.2337/dci23-0021 · Cited by 73
Self-citationSzmuilowicz, E. D., & Aleppo, G. (2022) · Postgraduate Medicine · doi:10.1080/00325481.2022.2110507 · Cited by 27
“Furthermore, HbA1c measurements are commonly discordant from average glucose measurements due to non-glycemic factors such as hemoglobinopathies or commonly encountered conditions in which red-cell turnover is altered, such as iron-deficiency anemia, chronic hemolysis, and chronic kidney disease [9].”
Background
Metadata
- Authors
- Perlman, J. E., Gooley, T. A., McNulty, B., Meyers, J., & Hirsch, I. B.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2021-04-01
- Volume
- 23
- Issue
- 4
- Pages
- 253-258
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W3109417769
- Cited by
- 93
- References
- 12
- FWCI
- 7.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.