Expert Guidance on Off-Label Use of Hybrid Closed-Loop Therapy in Pregnancies Complicated by Diabetes
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Automated insulin delivery (AID) systems have established benefits in terms of glycemic control, health outcomes, and quality of life and are strongly recommended for people with type 1 diabetes outside of pregnancy. While evidence for use of investigational AID systems during pregnancy is promising, data and guidance are still needed regarding use of commercially available systems during pregnancy. Unfortunately, none of the hybrid closed-loop (HCL) systems that are currently available in the United States have glucose targets that are as aggressive as pregnancy glycemic targets, none have a pregnancy-specific algorithm, and none are approved for use during pregnancy. As such, any use of these systems during pregnancy is considered off-label in the United States and would be "assisted" by provider/user techniques. Despite these limitations, many women conceive while using clinically available HCL systems and may be hesitant to cease use during pregnancy. Achievement of strict pregnancy glycemic targets can be difficult, and it is conceivable that selective off-label use of clinically available HCL systems in some women could lead to improved glycemia. We herein offer expert guidance based on clinical experience and available case reports on how to identify appropriate candidates for HCL therapy in pregnancy, how to counsel pregnant women with diabetes on the potential risks and benefits of HCL therapy during pregnancy, and how to manage commercially available systems off-label throughout gestation in an assisted HCL approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 2×
“…psTIR, psTBR (pregnancy-specific time below range), and psTAR (pregnancy-specific time above range) for pregnant women with type 1 diabetes using CGM. 19 25 Glycemic targets for pregnancy are difficult to achieve, with only 61%–68% of women achieving the psTIR and only in the final weeks of pregnancy,…”
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · cited 2×
“36 CGM use is considered adjunctive therapy during pregnancy, and thus, self-monitoring of blood glucose is still recommended throughout gestation to confirm treatment decisions.”
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185 · cited 1×
“CGM use has been associated with improvements in glycemic control during 21 and outside of pregnancy, 35,36 and has been shown to be cost-effective for type 1 diabetes management during 2,37 and outside of gestation.”
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Self-citationFeig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
Garg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585
15. Management of Diabetes in Pregnancy: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s015 · Cited by 504 · cited 3×
“18 The International Consensus on Time in Range recommended ps achievement goals as shown in Table 1 for psTIR, psTBR (pregnancy-specific time below range), and psTAR (pregnancy-specific time above range) for pregnant women with type 1 diabetes using CGM. 19 25 Glycemic targets for pregnancy are…”
Managing preexisting diabetes for pregnancy
Kitzmiller, J. L., Block, J. M., Brown, F. M., Catalano, P. M., Conway, D. L., Coustan, D. R., Gunderson, E. P., Herman, W. H., Hoffman, L. D., Inturrisi, M., et al. (2008) · Diabetes Care · doi:10.2337/dc08-9020 · Cited by 476
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Cited by
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
Self-citation7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Self-citation15. Management of Diabetes in Pregnancy: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s015 · Cited by 252
Self-citation15. Management of Diabetes in Pregnancy: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s015 · Cited by 232
Self-citationBenhalima, K., Beunen, K., Van Wilder, N., Ballaux, D., Vanhaverbeke, G., Taes, Y., Aers, X.-P., Nobels, F., Marlier, J., Lee, D., et al. (2024) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(24)00089-5 · Cited by 131
Metadata
- Authors
- Szmuilowicz, E. D., Levy, C. J., Buschur, E. O., & Polsky, S.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2023-05-01
- Volume
- 25
- Issue
- 5
- Pages
- 363-373
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W4318767442
- Cited by
- 58
- References
- 13
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Expert Guidance on Off-Label Use of Hybrid Closed-Loop Therapy in Pregnancies Complicated by Diabetes. https://app.cochat.ai/papers/10.1089/dia.2022.0540
- The paper
- Szmuilowicz, E. D., Levy, C. J., Buschur, E. O., & Polsky, S. (2023). Expert Guidance on Off-Label Use of Hybrid Closed-Loop Therapy in Pregnancies Complicated by Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2022.0540
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.