Trichloroethylene Degradation by Zero Valent Iron Activated Persulfate Oxidation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The present study describes the use of zero valent iron (Fe0 ) as a source for ferrous ion activated persulfate (PS) oxidation of trichloroethylene (TCE). The experimental results indicated that in the absence of TCE there was a lag time for persulfate decomposition when the reaction was activated by Fe0 . An initial pH drop in the Fe0 /PS system to acidic conditions was accompanied by the persulfate decomposition and a decrease in oxidation-reduction potential (ORP) values. Furthermore, in the TCE/Fe0 /PS system, the rapid TCE degradation was accompanied by the rapid persulfate decomposition and chloride ion formation as evidence of TCE mineralization. SEM images of Fe0 before and after persulfate oxidation exhibited significant corrosions of Fe0 . Acicular aggregate formation in the absence of TCE and coarse aggregate formation in the presence of TCE were observed. Moreover, the XRD spectrum revealed the formation of magnetite over the surface of Fe0 after contact with persulfate. Thus, Fe0 activated persulfate oxidation offers a fast and effective way for remediation of TCE contamination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanoscale iron particles for environmental remediation: An overview
Zhang, W.-X. (2003) · Journal of Nanoparticle Research · doi:10.1023/a:1025520116015 · Cited by 2,003 · cited 1×
“The observed variation of pH and ORP is similar to observations in common ZVI applications (Zhang, 2003).”
Cited by
Cao, J., Lai, L., Lai, B., Yao, G., Chen, X., & Song, L. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.01.113 · Cited by 647
Yan, J., Han, L., Gao, W., Xue, S., & Chen, M. (2015) · Bioresource Technology · doi:10.1016/j.biortech.2014.10.103 · Cited by 592
Sulfate Radical and Its Application in Decontamination Technologies
Zhang, B.-T., Zhang, Y., Teng, Y., & Fan, M. (2015) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2014.970681 · Cited by 536
Oh, W.-D., & Lim, T.-T. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.09.203 · Cited by 334
Degradation of sulfamethoxazole by persulfate assisted micrometric Fe0 in aqueous solution
Ghauch, A., Ayoub, G., & Naim, S. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.05.045 · Cited by 328
Physico-Chemical Processes for the Treatment of Per- And Polyfluoroalkyl Substances (PFAS): A review
Nzeribe, B. N., Crimi, M., Mededovic Thagard, S., & Holsen, T. M. (2019) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2018.1542916 · Cited by 314
Li, R., Jin, X., Megharaj, M., Naidu, R., & Chen, Z. (2015) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.11.128 · Cited by 300
Ayoub, G., & Ghauch, A. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.07.002 · Cited by 286
Zhao, J., Zhang, Y., Quan, X., & Chen, S. (2010) · Separation and Purification Technology · doi:10.1016/j.seppur.2009.12.010 · Cited by 284
Oxidative degradation of p-chloroaniline by copper oxidate activated persulfate
Liang, H.-Y., Zhang, Y.-Q., Huang, S.-B., & Hussain, I. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.11.093 · Cited by 276
Degradation of p-chloroaniline by persulfate activated with zero-valent iron
Hussain, I., Zhang, Y., Huang, S., & Du, X. (2012) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.06.120 · Cited by 275
Yuan, S., Liao, P., & Alshawabkeh, A. N. (2014) · Environmental Science & Technology · doi:10.1021/es404535q · Cited by 269
Zhen, G., Lu, X., Su, L., Kobayashi, T., Kumar, G., Zhou, T., Xu, K., Li, Y.-Y., Zhu, X., & Zhao, Y. (2018) · Water Research · doi:10.1016/j.watres.2018.01.072 · Cited by 256
Wang, X., Wang, L., Li, J., Qiu, J., Cai, C., & Zhang, H. (2014) · Separation and Purification Technology · doi:10.1016/j.seppur.2013.10.037 · Cited by 233
“Therefore, in the past years, the iron activated persulfate process has been applied to the degradation of various organic pollutants such as 4-chlorophenol [9], p-chloroaniline [10], 2,4-dinitrotoluene [13], naphthalene [21], polyvinyl alcohol [22], Reactive Blue 19 [23], and trichloroethylene [24].”
BackgroundHou, K., Pi, Z., Yao, F., Wu, B., He, L., Li, X., Wang, D., Dong, H., & Yang, Q. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.127078 · Cited by 227
Liu, Y., Luo, J., Tang, L., Feng, C., Wang, J., Deng, Y., Liu, H., Yu, J., Feng, H., & Wang, J. (2020) · ACS Catalysis · doi:10.1021/acscatal.0c04049 · Cited by 224
Liang, C., & Guo, Y.-Y. (2010) · Environmental Science & Technology · doi:10.1021/es903411a · Cited by 209
Self-citationTreatment of Organic Compounds by Activated Persulfate Using Nanoscale Zerovalent Iron
Al-Shamsi, M. A., & Thomson, N. R. (2013) · Industrial & Engineering Chemistry Research · doi:10.1021/ie400387p · Cited by 194
Li, H., Wan, J., Ma, Y., Wang, Y., & Huang, M. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2013.10.035 · Cited by 171
Duan, X., Sun, H., Tade, M., & Wang, S. (2018) · Catalysis Today · doi:10.1016/j.cattod.2017.04.038 · Cited by 156
Rayaroth, M. P., Lee, C.-S., Aravind, U. K., Aravindakumar, C. T., & Chang, Y.-S. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.01.031 · Cited by 126
Metadata
- Authors
- Liang, C., & Lai, M.-C.
- Venue
- Environmental Engineering Science
- Publisher
- SAGE Publications
- Published
- 2008-09
- Volume
- 25
- Issue
- 7
- Pages
- 1071-1078
- ISSN
- 1092-8758 (ISSN-L)
- 1557-9018
- OpenAlex
- W2091264883
- Cited by
- 149
- References
- 1
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.