Soft Robotics Technologies to Address Shortcomings in Today's Minimally Invasive Surgery: The STIFF-FLOP Approach

Cianchetti, Matteo, Ranzani, Tommaso, Gerboni, Giada, Nanayakkara, Thrishantha, Althoefer, Kaspar, Dasgupta, Prokar, Menciassi, Arianna·2014·Soft Robotics

Abstract

Most devices for single-site or natural orifice transluminal surgery are very application specific and, hence, capable of effectively carrying out specific surgical tasks only. However, most of these instruments are rigid, lack a sufficient number of degrees of freedom (DOFs), and/or are incapable of modifying their mechanical properties based on the tasks to be performed. The current philosophy in commercial instrument design is mainly focused on creating minimally invasive surgical systems using rigid tools equipped with dexterous tips. Only few research efforts are aimed at developing flexible surgical systems, with many DOFs or even continuum kinematics. The authors propose a radical change in surgical instrument design: away from rigid tools toward a new concept of soft and stiffness-controllable instruments. Inspired by biology, we envision creating such soft and stiffness-controllable medical devices using the octopus as a model. The octopus presents all the capabilities requested and can be viewed as a precious source of inspiration. Several soft technologies are suitable for meeting the aforementioned capabilities, and in this article a brief review of the most promising ones is presented. Then we illustrate how specific technologies can be applied in the design of a novel manipulator for flexible surgery by discussing its potential and by presenting feasibility tests of a prototype responding to this new design philosophy. Our aim is to investigate the feasibility of applying these technologies in the field of minimally invasive surgery and at the same time to stimulate the creativeness of others who could take the proposed concepts further to achieve novel solutions and generate specific application scenarios for the devised technologies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/soro.2014.0001

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 544

Metadata

Authors
Cianchetti, M., Ranzani, T., Gerboni, G., Nanayakkara, T., Althoefer, K., Dasgupta, P., & Menciassi, A.
Venue
Soft Robotics
Published
2014-06
Volume
1
Issue
2
Pages
122-131
ISSN
  • 2169-5172 (ISSN-L)
  • 2169-5180
OpenAlex
W2124992704
Cited by
544
References
1
FWCI
13.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Soft Robotics Technologies to Address Shortcomings in Today's Minimally Invasive Surgery: The STIFF-FLOP Approach. https://app.cochat.ai/papers/10.1089/soro.2014.0001
The paper
Cianchetti, M., Ranzani, T., Gerboni, G., Nanayakkara, T., Althoefer, K., Dasgupta, P., & Menciassi, A. (2014). Soft Robotics Technologies to Address Shortcomings in Today's Minimally Invasive Surgery: The STIFF-FLOP Approach. Soft Robotics. https://doi.org/10.1089/soro.2014.0001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.