The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Soft Robotics Technologies to Address Shortcomings in Today's Minimally Invasive Surgery: The STIFF-FLOP Approach
Abstract
Most devices for single-site or natural orifice transluminal surgery are very application specific and, hence, capable of effectively carrying out specific surgical tasks only. However, most of these instruments are rigid, lack a sufficient number of degrees of freedom (DOFs), and/or are incapable of modifying their mechanical properties based on the tasks to be performed. The current philosophy in commercial instrument design is mainly focused on creating minimally invasive surgical systems using rigid tools equipped with dexterous tips. Only few research efforts are aimed at developing flexible surgical systems, with many DOFs or even continuum kinematics. The authors propose a radical change in surgical instrument design: away from rigid tools toward a new concept of soft and stiffness-controllable instruments. Inspired by biology, we envision creating such soft and stiffness-controllable medical devices using the octopus as a model. The octopus presents all the capabilities requested and can be viewed as a precious source of inspiration. Several soft technologies are suitable for meeting the aforementioned capabilities, and in this article a brief review of the most promising ones is presented. Then we illustrate how specific technologies can be applied in the design of a novel manipulator for flexible surgery by discussing its potential and by presenting feasibility tests of a prototype responding to this new design philosophy. Our aim is to investigate the feasibility of applying these technologies in the field of minimally invasive surgery and at the same time to stimulate the creativeness of others who could take the proposed concepts further to achieve novel solutions and generate specific application scenarios for the devised technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Jamming is not just cool any more
Liu, A. J., & Nagel, S. R. (1998) · Nature · doi:10.1038/23819 · Cited by 1,875
Soft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708
Universal robotic gripper based on the jamming of granular material
Brown, E., Rodenberg, N., Amend, J., Mozeika, A., Steltz, E., Zakin, M. R., Lipson, H., & Jaeger, H. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003250107 · Cited by 1,603
Stimulus-responsive shape memory materials: a review
Sun, L., Huang, W. M., Ding, Z., Zhao, Y., Wang, C. C., Purnawali, H., & Tang, C. (2012) · Materials & Design · doi:10.1016/j.matdes.2011.04.065 · Cited by 1,105 · cited 1×
“24 Fluidic actuators could represent a different, yet effective, solution especially if combined with specific manufacturing processes for soft devices.”
Tadaki, T., Otsuka, K., & Shimizu, K. (1988) · Annual Review of Materials Science · doi:10.1146/annurev.ms.18.080188.000325 · Cited by 1,030
Soft Robot Arm Inspired by the Octopus
Laschi, C., Cianchetti, M., Mazzolai, B., Margheri, L., Follador, M., & Dario, P. (2012) · Advanced Robotics · doi:10.1163/156855312x626343 · Cited by 978
Self-citationMirfakhrai, T., Madden, J. D. W., & Baughman, R. H. (2007) · Materials Today · doi:10.1016/s1369-7021(07)70048-2 · Cited by 933
Robotic Tentacles with Three‐Dimensional Mobility Based on Flexible Elastomers
Martinez, R. V., Branch, J. L., Fish, C. R., Jin, L., Shepherd, R. F., Nunes, R. M. D., Suo, Z., & Whitesides, G. M. (2013) · Advanced Materials · doi:10.1002/adma.201203002 · Cited by 718
Mechanics of Precurved-Tube Continuum Robots
Webster, R. J., Romano, J. M., & Cowan, N. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2006868 · Cited by 485
Emerging Robotic Platforms for Minimally Invasive Surgery
Vitiello, V., Lee, S.-L., Cundy, T. P., & Yang, G.-Z. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2236311 · Cited by 457
A Novel Layer Jamming Mechanism With Tunable Stiffness Capability for Minimally Invasive Surgery
Kim, Y.-J., Cheng, S., Kim, S., & Iagnemma, K. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2013.2256313 · Cited by 428
Continuous Backbone “Continuum” Robot Manipulators
Walker, I. D. (2013) · ISRN Robotics · doi:10.5402/2013/726506 · Cited by 405
Cheng, N. G., Lobovsky, M. B., Keating, S. J., Setapen, A. M., Gero, K. I., Hosoi, A. E., & Iagnemma, K. D. (2012) · 2012 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2012.6225373 · Cited by 314
Cianchetti, M., Ranzani, T., Gerboni, G., De Falco, I., Laschi, C., & Menciassi, A. (2013) · 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2013.6696866 · Cited by 304
Self-citation2011 IEEE International Conference on Robotics and Automation (ICRA 2011)
(2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2062334 · Cited by 302
Conductive Electroactive Polymers: Intelligent Polymer Systems, Third Edition
Wallace, G. G., Teasdale, P. R., Spinks, G. M., & Kane-Maguire, L. A. P. (2008) · CRC Press eBooks · doi:10.1201/9781420067156 · Cited by 285
2011 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS2011)
Watanabe, T., & Okamoto, S. (2012) · Journal of the Robotics Society of Japan · doi:10.7210/jrsj.30.388 · Cited by 266
Stiffness Control of Surgical Continuum Manipulators
Mahvash, M., & Dupont, P. E. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2105410 · Cited by 265
Conductive Electroactive Polymers: Intelligent Polymer Systems
Wallace, G. G., Spinks, G. M., Kane‐Maguire, L. A. P., & Teasdale, P. R. (2009) · Research Online (University of Wollongong) · Cited by 244
Soft-matter composites with electrically tunable elastic rigidity
Shan, W., Lu, T., & Majidi, C. (2013) · Smart Materials and Structures · doi:10.1088/0964-1726/22/8/085005 · Cited by 233
Analysis and development of locomotion devices for the gastrointestinal tract
Phee, L., Accoto, D., Menciassi, A., Stefanini, C., Carrozza, M. C., & Dario, P. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1001976 · Cited by 206
Self-citationTowards flexible medical instruments: Review of flexible fluidic actuators
De Greef, A., Lambert, P., & Delchambre, A. (2009) · Precision Engineering · doi:10.1016/j.precisioneng.2008.10.004 · Cited by 204
Characterization of silicone rubber based soft pneumatic actuators
Sun, Y., Song, Y. S., & Paik, J. (2013) · 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2013.6696995 · Cited by 199
Scopes Too Flexible...and Too Stiff
Loeve, A., Breedveld, P., & Dankelman, J. (2010) · IEEE Pulse · doi:10.1109/mpul.2010.939176 · Cited by 190
An articulated universal joint based flexible access robot for minimally invasive surgery
Shang, J., Noonan, D. P., Payne, C. J., Clark, J., Sodergren, M. H., Darzi, A. W., & Yang, G. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5980261 · Cited by 156
The development of a robotic endoscope
Slatkin, A. B., Burdick, J. W., & Grundfest, W. S. (2002) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.1995.526155 · Cited by 154
The Bionic Handling Assistant: a success story of additive manufacturing
Grzesiak, A., Becker, R., & Verl, A. W. (2011) · Assembly Automation · doi:10.1108/01445151111172907 · Cited by 144
Flexible microactuator for miniature robots
Suzumori, K., Iikura, S., & Tanaka, H. (2002) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.1991.114797 · Cited by 133
Vacuum packed particles as flexible endoscope guides with controllable rigidity
Loeve, A. J., van de Ven, O. S., Vogel, J. G., Breedveld, P., & Dankelman, J. (2010) · Granular Matter · doi:10.1007/s10035-010-0193-8 · Cited by 115
Jamming as an enabling technology for soft robotics
Steltz, E., Mozeika, A., Rembisz, J., Corson, N., & Jaeger, H. M. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.853182 · Cited by 104
An optical curvature sensor for flexible manipulators
Searle, T., Althoefer, K. A., Seneviratne, L. D., & Liu, H. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631203 · Cited by 69
Self-citationThe development of a robotic endoscope
Slatkin, A. B., Burdick, J. W., & Grundfest, W. S. (1997) · Lecture notes in control and information sciences · doi:10.1007/bfb0035207 · Cited by 66
Highly articulated robotic probe for minimally invasive surgery
Degani, A., Choset, H., Zubiate, B., Ota, T., & Zenati, M. A. (2008) · doi:10.1109/iembs.2008.4649903 · Cited by 53
Fundamentals on the Use of Shape Memory Alloys in Soft Robotics
Cianchetti, M. (2013) · doi:10.1002/9781118577516.ch10 · Cited by 39
Self-citationA comparative study for robot assisted vitreoretinal surgery: Micron vs. the Steady-Hand Robot
Gonenc, B., Handa, J. T., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631266 · Cited by 32
Vyas, L., Aquino, D., Kuo, C., Dai, J. S., & Prokar Dasgupta, A. (2011) · British Journal of Urology · doi:10.1111/j.1464-410x.2010.09886.x · Cited by 22
Cited by
Soft robotics: Technologies and systems pushing the boundaries of robot abilities
Laschi, C., Mazzolai, B., & Cianchetti, M. (2016) · Science Robotics · doi:10.1126/scirobotics.aah3690 · Cited by 1,570
Self-citationPolygerinos, P., Correll, N., Morin, S. A., Mosadegh, B., Onal, C. D., Petersen, K., Cianchetti, M., Tolley, M. T., & Shepherd, R. F. (2017) · Advanced Engineering Materials · doi:10.1002/adem.201700016 · Cited by 1,063
Self-citationSoft Robotic Grippers for Biological Sampling on Deep Reefs
Galloway, K. C., Becker, K. P., Phillips, B., Kirby, J., Licht, S., Tchernov, D., Wood, R. J., & Gruber, D. F. (2016) · Soft Robotics · doi:10.1089/soro.2015.0019 · Cited by 848
A Recipe for Soft Fluidic Elastomer Robots
Marchese, A. D., Katzschmann, R. K., & Rus, D. (2015) · Soft Robotics · doi:10.1089/soro.2014.0022 · Cited by 649
Stiffening in Soft Robotics: A Review of the State of the Art
Manti, M., Cacucciolo, V., & Cianchetti, M. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2016.2582718 · Cited by 637
Self-citation
Metadata
- Authors
- Cianchetti, M., Ranzani, T., Gerboni, G., Nanayakkara, T., Althoefer, K., Dasgupta, P., & Menciassi, A.
- Venue
- Soft Robotics
- Publisher
- SAGE Publications
- Published
- 2014-06
- Volume
- 1
- Issue
- 2
- Pages
- 122-131
- ISSN
- 2169-5172 (ISSN-L)
- 2169-5180
- OpenAlex
- W2124992704
- Cited by
- 544
- References
- 37
- FWCI
- 13.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.