Fully Wearable Actuated Soft Exoskeleton for Grasping Assistance in Everyday Activities
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Worldwide, over 50 million people suffer from persistent hand impairments after stroke or spinal cord injury (SCI). This results in major loss of independence and quality of life. Robotic hand exoskeletons can compensate for lost motor function and assist in grasping tasks performed in everyday activities. Several recent prototypes can partially provide this assistance. However, it remains challenging to integrate the dexterity required for daily tasks in a safe and user-friendly design that is acceptable for daily use in subjects with neuromotor hand impairments. We present the design of RELab tenoexo; a fully wearable assistive soft hand exoskeleton for daily activities. We present sleek mechanisms for a hand module that generates the four most frequently used grasp types, employing a remote actuation system that reduces weight on the hand. For optimal assistance and highest adaptability, we present various design and control options to customize the modular device, along with an automated tailoring algorithm that allows automatically generated hand modules for individual users. Mechanical evaluation shows that RELab tenoexo covers the range of motion and the fingertip forces required to assist users in up to 80% of all grasping activities. In user tests, we find that the low weight, unintrusive size, high wearing comfort, and appealing appearance are beneficial for user acceptance and usability in daily life. Finally, we demonstrate that RELab tenoexo leads to an immediate improvement of the functional grasping ability in a subject with SCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hudak, P. L., Amadio, P. C., Bombardier, C., Beaton, D., Cole, D., Davis, A., Hawker, G., Katz, J. N., Makela, M., Marx, R. G., et al. (1996) · American Journal of Industrial Medicine · doi:10.1002/(sici)1097-0274(199606)29:6<602::aid-ajim4>3.0.co;2-l · Cited by 5,025
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
Cited by
A Review of Active Hand Exoskeletons for Rehabilitation and Assistance
du Plessis, T., Djouani, K., & Oosthuizen, C. (2021) · Robotics · doi:10.3390/robotics10010040 · Cited by 218
“The number of electrodes used is generally less than the number of DOF of the hand; therefore, it can be challenging to get independent high DOF measurements [54,60,64,70,72].”
BackgroundMethodInfluential
Metadata
- Authors
- Bützer, T., Lambercy, O., Arata, J., & Gassert, R.
- Venue
- Soft Robotics
- Publisher
- SAGE Publications
- Published
- 2021-04-01
- Volume
- 8
- Issue
- 2
- Pages
- 128-143
- ISSN
- 2169-5172 (ISSN-L)
- 2169-5180
- OpenAlex
- W3036156867
- Cited by
- 246
- References
- 3
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.