Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 175

The DOI matches its Crossref record.

In Vitro Analysis of a Nanocrystalline Silver-Coated Surgical Mesh

Cohen, Michael S., Stern, Joshua M., Vanni, Alex J., Kelley, Robert S., Baumgart, Egbert, Field, David, Libertino, John A., Summerhayes, Ian C. · 2007 · Surgical Infections

Abstract

BACKGROUND AND PURPOSE: One million nosocomial infections occur each year in patients with prosthetic devices. We analyzed a polypropylene mesh coated with nanocrystalline silver particles (NCSP) as a means of preventing such infections. METHODS: Nanocrystalline silver was applied to polypropylene mesh using physical vapor deposition in three doses: low (0.31 mg/cm(2)), medium (0.64 mg/cm(2)), and high (1.13 mg/cm(2)). The zone of inhibition (ZOI) test was conducted by incubating either uncoated polypropylene mesh (UM) or silver-coated mesh (CM) with and without various amounts of bovine serum albumin (BSA) and then on agar plates with Staphylococcus aureus and calculating the ZOI. The bactericidal effects of the NCSP-coated meshes were assessed by incubating either UM or CM in medium with S. aureus and performing serial dilutions at 4 and 8 h. Scanning electron microscopy (SEM) was used to examine the surface of UM and CM with and without bacterial incubation. RESULTS: There was an increasing ZOI for low-, medium-, and high-dose CM and no ZOI for UM (p < 0.001 for all CM compared with UM). Incubating the mesh with various amounts of BSA produced persistent ZOIs with the medium- and high-dose CM; however, the low-dose CM became attenuated by such treatment, with no ZOI being seen with meshes incubated in 10% BSA. All concentrations of CM were bactericidal, as no bacteria grew at 8 h of incubation. The SEM images showed clusters of S. aureus on the surface of UM and no clusters on CM. CONCLUSIONS: The CM demonstrated significant bactericidal activity compared with UM. Nanocrystalline silver particles may decrease the incidence of postoperative prosthetic mesh infections and be useful as a coating for other prosthetic materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/sur.2006.032

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Cohen, M. S., Stern, J. M., Vanni, A. J., Kelley, R. S., Baumgart, E., Field, D., Libertino, J. A., & Summerhayes, I. C.
Venue
Surgical Infections
Published
2007-06
Volume
8
Issue
3
Pages
397-404
ISSN
  • 1096-2964 (ISSN-L)
  • 1557-8674
OpenAlex
W2015780991
Cited by
175
References
0
FWCI
4.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.