Nanofabrication and Microfabrication of Functional Materials for Tissue Engineering
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The burgeoning field of regenerative medicine promises significant progress in the treatment of cardiac ischemia, liver disease, and spinal cord injury. Key to its success will be the ability to engineer tissue safely and reliably. Tissue functionality must be recapitulated in the laboratory and then integrated into surrounding tissue upon transfer to the patient. Scaffolding materials must be chosen such that the microenvironment surrounding the cells is a close analog of the native environment. In the early days of tissue engineering, these materials were largely borrowed from other fields, with much of the focus on biocompatibility and biodegradation. However, attention has shifted recently to cell-cell and cell-surface interactions, largely because of enabling technologies at the nanoscale and microscale. Studies on cellular behavior in response to various stimuli are now easily realized by using microfabrication techniques and devices (e.g., biomedical microelectromechanical systems). These experiments are reproducible and moderate in cost, and often can be accomplished at high throughput, providing the fundamental knowledge required to design biomaterials that closely mimic the biological system. It is our opinion that these novel materials and technologies will bring engineered tissues one step closer to practical application in the clinic. This review discusses their application to cardiac, liver, and nerve tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Altman, G. H., Diaz, F., Jakuba, C., Calabro, T., Horan, R. L., Chen, J., Lu, H., Richmond, J., & Kaplan, D. L. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00353-8 · Cited by 3,458 · cited 1×
“24,30 This has led to interest in biological polymers such as collagen, 31 alginate, 32 silk, 33,34 hyaluronic acid, 35 and chitosan.”
A tough biodegradable elastomer
Wang, Y., Ameer, G. A., Sheppard, B. J., & Langer, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0602-602 · Cited by 1,314
Self-citationTissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
Nanoliter-scale synthesis of arrayed biomaterials and application to human embryonic stem cells
Anderson, D. G., Levenberg, S., & Langer, R. (2004) · Nature Biotechnology · doi:10.1038/nbt981 · Cited by 747 · cited 2×
“43 Array-synthesized NANOFABRICATION AND MICROFABRICATION FOR TISSUE ENGINEERING acrylate-based polymers deposited onto poly(hydroxyethyl methacrylate) (pHEMA) were used to study the differentiation of human embryonic stem cells and the C2C12 muscle cell line on the polymers, providing a possible…”
Self-citationEschenhagen, T., Fink, C., Remmers, U., Scholz, H., Wattchow, J., Weil, J., Zimmermann, W., Dohmen, H. H., Schäfer, H., Bishopric, N., et al. (1997) · The FASEB Journal · doi:10.1096/fasebj.11.8.9240969 · Cited by 636 · cited 1×
“5,7,8 Bioreactors, such as the National Aeronautics and Space Administration’s STLV (slow-turning lateral vessel) and HARV (high aspect ratio vessel), recreate this environment to some extent by supporting the high metabolic demands of cardiac tissue, and have been successfully used to culture…”
Cited by
The interaction of cells and bacteria with surfaces structured at the nanometre scale
Anselme, K., Davidson, P., Popa, A. M., Giazzon, M., Liley, M., & Ploux, L. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.04.001 · Cited by 827
Ghasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M. H., Baharvand, H., Kiani, S., Al-Deyab, S. S., & Ramakrishna, S. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.383 · Cited by 698
Nanoscale cues regulate the structure and function of macroscopic cardiac tissue constructs
Kim, D.-H., Lipke, E. A., Kim, P., Cheong, R., Thompson, S., Delannoy, M., Suh, K.-Y., Tung, L., & Levchenko, A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0906504107 · Cited by 611
“Recent advances in nanofabrication techniques can enable the design and fabrication of scalable scaffolding materials mimicking the structural and mechanical cues present in the in vivo ECM environment (1, 11).”
BackgroundA Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Electrospun polymeric nanofibres as wound dressings: A review
Miguel, S. P., Figueira, D. R., Simões, D., Ribeiro, M. P., Coutinho, P., Ferreira, P., & Correia, I. J. (2018) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2018.05.011 · Cited by 362
Metadata
- Authors
- Park, H., Cannizzaro, C., Vunjak-Novakovic, G., Langer, R., Vacanti, C. A., & Farokhzad, O. C.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2007-08
- Volume
- 13
- Issue
- 8
- Pages
- 1867-1877
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2119650320
- Cited by
- 123
- References
- 6
- FWCI
- 14.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.