The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Osteochondral Defect Repair with Autologous Bone Marrow–Derived Mesenchymal Stem Cells in an Injectable, In Situ , Cross-Linked Synthetic Extracellular Matrix
Abstract
A co-cross-linked synthetic extracellular matrix (sECM) composed of chemically modified hyaluronic acid and gelatin was used as a cell delivery vehicle for osteochondral defect repair in a rabbit model. A full-thickness defect was created in the patellar groove of the femoral articular cartilage in each of 2 rabbit joints, and 4 experimental groups were assigned (12 rabbits/group): untreated control, autologous mesenchymal stem cells (MSCs) only, sECM only, and MSCs + sECM. The sECM hydrogels were allowed to cross-link in the defect in situ. Rabbits were sacrificed at 4, 8, and 12 weeks post-surgery, and cartilage repair was evaluated and scored. In the controls, defects were filled with fibrous tissue. In the MSC-only group, hyaline-like cartilage filled the peripheral area of the defect, but the center was filled with fibrous tissue. In the sECM-only group, hyaline cartilage with zonal architecture filled the defect at 12 weeks, but an interface between repaired and adjacent host cartilage was evident. In the MSCs + sECM group, defects were completely filled with elastic, firm, translucent cartilage at 12 weeks and showed superior integration of the repair tissue with the normal cartilage. The sECM delivers and retains MSCs, and the injectable cell-seeded sECM could be delivered arthroscopically in the clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photopolymerizable hydrogels for tissue engineering applications
Nguyen, K. T., & West, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00175-8 · Cited by 1,669
Bryant, S. J., & Anseth, K. S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1217 · Cited by 845
Cited by
Hyaluronic Acid Hydrogels for Biomedical Applications
Burdick, J. A., & Prestwich, G. D. (2011) · Advanced Materials · doi:10.1002/adma.201003963 · Cited by 2,139
Self-citationMalafaya, P. B., Silva, G. A., & Reis, R. L. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.012 · Cited by 1,401
Cell Encapsulation in Biodegradable Hydrogels for Tissue Engineering Applications
Nicodemus, G. D., & Bryant, S. J. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0332 · Cited by 1,239
Hyaluronic acid based scaffolds for tissue engineering—A review
Collins, M. N., & Birkinshaw, C. (2013) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2012.10.028 · Cited by 1,092
Chung, C., & Burdick, J. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.027 · Cited by 760
Metadata
- Authors
- Liu, Y., Shu, X. Z., & Prestwich, G. D.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2006-12
- Volume
- 12
- Issue
- 12
- Pages
- 3405-3416
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2075635866
- Cited by
- 214
- References
- 2
- FWCI
- 8.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Osteochondral Defect Repair with Autologous Bone Marrow–Derived Mesenchymal Stem Cells in an Injectable, In Situ , Cross-Linked Synthetic Extracellular Matrix. https://app.cochat.ai/papers/10.1089/ten.2006.12.3405
- The paper
- Liu, Y., Shu, X. Z., & Prestwich, G. D. (2006). Osteochondral Defect Repair with Autologous Bone Marrow–Derived Mesenchymal Stem Cells in an Injectable, In Situ , Cross-Linked Synthetic Extracellular Matrix. Tissue Engineering. https://doi.org/10.1089/ten.2006.12.3405
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.