Functional Tissue-Engineered Valves from Cell-Remodeled Fibrin with Commissural Alignment of Cell-Produced Collagen
The DOI matches its Crossref record.
Abstract
Heart valve replacements composed of living tissue that can adapt, repair, and grow with a patient would provide a more clinically beneficial option than current inert replacements. Bioartificial valves were produced by entrapping human dermal fibroblasts within a fibrin gel. Using a mold design that presents appropriate mechanical constraints to the cell-induced fibrin gel compaction, gross fiber alignment (commissure-to-commissure alignment in the leaflets and circumferential alignment in the root) and the basic geometry of a native aortic valve were obtained. After static incubation on the mold in complete medium supplemented with transforming growth factor beta 1, insulin, and ascorbate, collagen fibers produced by the entrapped cells were found to coalign with the fibrin based on histological analyses. The resultant tensile mechanical properties were anisotropic. Ultimate tensile strength and tensile modulus of the leaflets in the commissural direction were 0.53 and 2.34 MPa, respectively. The constructs were capable of withstanding backpressure commensurate with porcine aortic valves in regurgitation tests (330 mmHg) and opened and closed under physiological pressure swings of 10 and 20 mmHg, respectively. These data support proof of principle of using cell-remodeled fibrin gel to produce tissue-engineered valve replacements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hockaday, L. A., Kang, K. H., Colangelo, N. W., Cheung, P. Y. C., Duan, B., Malone, E., Wu, J., Girardi, L. N., Bonassar, L. J., Lipson, H., et al. (2012) · Biofabrication · doi:10.1088/1758-5082/4/3/035005 · Cited by 683
Schoen, F. J. (2008) · Circulation · doi:10.1161/circulationaha.108.805911 · Cited by 421
Biofabrication: a 21st century manufacturing paradigm
Mironov, V, Trusk, T., Kasyanov, V, Little, S., Swaja, R., & Markwald, R. (2009) · Biofabrication · doi:10.1088/1758-5082/1/2/022001 · Cited by 362
Hybrid Multicomponent Hydrogels for Tissue Engineering
Jia, X., & Kiick, K. L. (2009) · Macromolecular Bioscience · doi:10.1002/mabi.200800284 · Cited by 308
Engineered skeletal muscle tissue networks with controllable architecture
Bian, W., & Bursac, N. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.11.015 · Cited by 287
Next-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity
Fioretta, E. S., Motta, S. E., Lintas, V., Loerakker, S., Parker, K. K., Baaijens, F. P. T., Falk, V., Hoerstrup, S. P., & Emmert, M. Y. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0422-8 · Cited by 262
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Bioengineering Challenges for Heart Valve Tissue Engineering
Sacks, M. S., Schoen, F. J., & Mayer, J. E. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124903 · Cited by 256
Das, S., Kim, S.-W., Choi, Y.-J., Lee, S., Lee, S.-H., Kong, J.-S., Park, H.-J., Cho, D.-W., & Jang, J. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.04.026 · Cited by 150
JetValve: Rapid manufacturing of biohybrid scaffolds for biomimetic heart valve replacement
Capulli, A. K., Emmert, M. Y., Pasqualini, F. S., Kehl, D., Caliskan, E., Lind, J. U., Sheehy, S. P., Park, S. J., Ahn, S., Weber, B., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.04.033 · Cited by 112
Metadata
- Authors
- Robinson, P. S., Johnson, S. L., Evans, M. C., Barocas, V. H., & Tranquillo, R. T.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2008-01
- Volume
- 14
- Issue
- 1
- Pages
- 83-95
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W2074449010
- Cited by
- 125
- References
- 0
- FWCI
- 14.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.