Growth Factor-Rich Plasma Increases Tendon Cell Proliferation and Matrix Synthesis on a Synthetic Scaffold: An In Vitro Study
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Numerous scaffolds have been proposed for use in connective tissue engineering. Although these scaffolds direct cell migration and attachment, many are biologically inert and thus lack the physiological stimulus to attract cells and induce mitogenesis and matrix synthesis. In the current study, a bioactive scaffold was created by combining a synthetic scaffold with growth factor-rich plasma (GFRP), an autologous concentration of growth factors derived from a platelet-rich plasma preparation. In vitro tendon cell proliferation and matrix synthesis on autologous GFRP-enriched scaffolds, autologous serum-enriched scaffolds, and scaffolds alone were compared. The GFRP preparation was found to have a 4.7-fold greater concentration of a sentinel growth factor (transforming growth factor-beta1) compared with serum. When combined with media containing calcium, the GFRP produced a thin fibrin matrix over and within the GFRP-enriched scaffolds. Cell proliferation assays demonstrated that GFRP-enriched scaffolds significantly enhanced cell proliferation over autologous serum and control groups at both 48 and 72 h. Analysis of the scaffolds at 14, 21, and 28 days revealed that GFRP-enriched scaffolds significantly increased the deposition of a collagen-rich extracellular matrix when compared with the other groups. These results indicate that GFRP can be used to enhance in vitro cellular population and matrix deposition of tissue-engineered scaffolds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fibrin: A versatile scaffold for tissue engineering applications
Ahmed, T. A. E., Dare, E. V., & Hincke, M. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0435 · Cited by 994 · cited 1×
“Fibrin has been shown to be an excellent provisional scaffold in a variety of applications providing a naturally derived matrix for cell adhesion= attachment and migration.(42) Several elegant studies have demonstrated that fibrin coating of synthetic substrates resulted in an increase in initial cell adherence, which…”
Scar–free healing: from embryonic mechanisms to adult therapeutic intervention
Ferguson, M. W. J., & O'Kane, S. (2004) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2004.1475 · Cited by 812
Can Platelet-Rich Plasma Enhance Tendon Repair?: A Cell Culture Study
de Mos, M., van der Windt, A. E., Jahr, H., van Schie, H. T. M., Weinans, H., Verhaar, J. A. N., & van Osch, G. J. V. M. (2008) · The American Journal of Sports Medicine · doi:10.1177/0363546508314430 · Cited by 423 · cited 2×
“…results have been reported regarding the ability to concentrate TGF-b 1 10,17,32,34,35 in addition to other growth factors such as platelet-derived growth factor 17,32,34,36 and vascular endothelial growth factor 34,36 in various PRP preparations compared with other blood-derived components.”
Schnabel, L. V., Mohammed, H. O., Miller, B. J., McDermott, W. G., Jacobson, M. S., Santangelo, K. S., & Fortier, L. A. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20278 · Cited by 403
McCarrel, T., & Fortier, L. (2009) · Journal of Orthopaedic Research · doi:10.1002/jor.20853 · Cited by 389 · cited 2×
“Therefore, the significant increase in cell and tissue proliferation seen in the GFRP group in the current study may not be a result of the fibrin coating alone but rather the combination of increase initial cell adhesion as well as the increased concentration of mitogenic growth factors present in the fibrin scaffold…”
Platelet concentrate injection improves Achilles tendon repair in rats
Aspenberg, P., & Virchenko, O. (2004) · Acta Orthopaedica Scandinavica · doi:10.1080/00016470410001708190 · Cited by 338
Murray, M. M., Spindler, K. P., Abreu, E., Muller, J. A., Nedder, A., Kelly, M., Frino, J., Zurakowski, D., Valenza, M., Snyder, B. D., et al. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20282 · Cited by 321
Murray, M. M., Spindler, K. P., Ballard, P., Welch, T. P., Zurakowski, D., & Nanney, L. B. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20367 · Cited by 300
Growth factor binding to the pericellular matrix and its importance in tissue engineering☆
MACRI, L., SILVERSTEIN, D., & CLARK, R. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.015 · Cited by 292
Murray, M. M., Spindler, K. P., Devin, C., Snyder, B. S., Muller, J., Takahashi, M., Ballard, P., Nanney, L. B., & Zurakowski, D. (2006) · Journal of Orthopaedic Research · doi:10.1002/jor.20073 · Cited by 193
Cited by
Amable, P. R., Carias, R. B. V., Teixeira, M. V. T., da Cruz Pacheco, Í., Corrêa do Amaral, R. J. F., Granjeiro, J. M., & Borojevic, R. (2013) · Stem Cell Research & Therapy · doi:10.1186/scrt218 · Cited by 725
Toward delivery of multiple growth factors in tissue engineering
Chen, F.-M., Zhang, M., & Wu, Z.-F. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.053 · Cited by 649
Sports Medicine Applications of Platelet Rich Plasma
Mishra, A., Harmon, K., Woodall, J., & Vieira, A. (2012) · Current Pharmaceutical Biotechnology · doi:10.2174/138920112800624283 · Cited by 397
Mishra, A. K., Skrepnik, N. V., Edwards, S. G., Jones, G. L., Sampson, S., Vermillion, D. A., Ramsey, M. L., Karli, D. C., & Rettig, A. C. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546513494359 · Cited by 396
A review on endogenous regenerative technology in periodontal regenerative medicine
Chen, F.-M., Zhang, J., Zhang, M., An, Y., Chen, F., & Wu, Z.-F. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.07.019 · Cited by 380
Platelet-Rich Plasma Releasate Promotes Differentiation of Tendon Stem Cells into Active Tenocytes
Zhang, J., & Wang, J. H.-C. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546510376750 · Cited by 256
Jo, C. H., Kim, J. E., Yoon, K. S., & Shin, S. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546512437525 · Cited by 248
“The in vitro effects of PRP on tenocytes have been reported previously by a few authors.(3,4,12,48,56,60,68) Three of these studies described the effects of PRP on tenocyte proliferation and/or matrix synthesis.”
BackgroundTuning the biomimetic behavior of scaffolds for regenerative medicine through surface modifications
Richbourg, N. R., Peppas, N. A., & Sikavitsas, V. I. (2019) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.2859 · Cited by 204
“A specially designed serum for protein deposition, named growth factor‐rich plasma, caused tenocytes cultured on treated polymer weaves to adhere, proliferate, and develop a greater fibrin matrix than serum‐treated and untreated scaffolds (Visser et al., 2010).”
BackgroundSanto, V. E., Duarte, A. R. C., Popa, E. G., Gomes, M. E., Mano, J. F., & Reis, R. L. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.06.001 · Cited by 82
“in vivo regeneration of the tissues, recapitulating the native environment with a biomimetic 3D structure [2,4].”
Background
Metadata
- Authors
- Visser, L. C., Arnoczky, S. P., Caballero, O., Kern, A., Ratcliffe, A., & Gardner, K. L.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2010-03
- Volume
- 16
- Issue
- 3
- Pages
- 1021-1029
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W2011070551
- Cited by
- 73
- References
- 10
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.