CoChat

A Novel Single-Step Self-Assembly Approach for the Fabrication of Tissue-Engineered Vascular Constructs

Gauvin, Robert, Ahsan, Taby, Larouche, Danielle, Lévesque, Philippe, Dubé, Jean, Auger, François A., Nerem, Robert M., Germain, Lucie · 2010 · Tissue Engineering Part A
Cited by 113

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

There is a clinical need for a functional tissue-engineered blood vessel because small-caliber arterial graft (<5 mm) applications are limited by the availability of suitable autologous vessels and suboptimal performances of synthetic grafts. This study presents an analysis of the mechanical properties of tissue-engineered vascular constructs produced using a novel single-step self-assembly approach. Briefly, the tissue-engineered vascular media were produced by culturing smooth muscle cell in the presence of sodium l -ascorbate until the formation of a cohesive tissue sheet. This sheet was then rolled around a tubular support to create a media construct. Alternatively, the tissue-engineered vascular adventitia was produced by rolling a tissue sheet obtained from dermal fibroblasts or saphenous vein fibroblasts. The standard self-assembly approach to obtain the two-layer tissue-engineered vascular constructs comprising both media and adventitia constructs consists of two steps in which tissue-engineered vascular media were first rolled on a tubular support and a tissue-engineered vascular adventitia was then rolled on top of the first layer. This study reports an original alternative method for assembling tissue-engineered vascular constructs comprising both media and an adventitia in a single step by rolling a continuous tissue sheet containing both cell types contiguously. This tissue sheet was produced by growing smooth muscle cells alongside fibroblasts (saphenous vein fibroblasts or dermal fibroblasts) in the same culture dish separated by a spacer, which is removed later in the culture period. The mechanical strength assessed by uniaxial tensile testing, burst pressure measurements, and viscoelastic behavior evaluated by stepwise stress relaxation tests reveals that the new single-step fabrication method significantly improves the mechanical properties of tissue-engineered vascular construct for both ultimate tensile strength and all the viscoelastic moduli.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tea.2009.0313

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 113

Metadata

Authors
Gauvin, R., Ahsan, T., Larouche, D., Lévesque, P., Dubé, J., Auger, F. A., Nerem, R. M., & Germain, L.
Venue
Tissue Engineering Part A
Published
2010-02-16
Volume
16
Issue
5
Pages
1737-1747
ISSN
  • 1937-3341 (ISSN-L)
  • 1937-335X
OpenAlex
W2049001245
Cited by
113
References
2
FWCI
8.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.