The DOI matches its Crossref record.
A Collagen–Chitosan Hydrogel for Endothelial Differentiation and Angiogenesis
Abstract
Cell therapy for the treatment of cardiovascular disease has been hindered by low cell engraftment, poor survival, and inadequate phenotype and function. In this study, we added chitosan to a previously developed injectable collagen matrix, with the aim of improving its properties for cell therapy and neovascularization. Different ratios of collagen and chitosan were mixed and chemically crosslinked to produce hydrogels. Swell and degradation assays showed that chitosan improved the stability of the collagen hydrogel. In culture, endothelial cells formed significantly more vascular-like structures on collagen–chitosan than collagen-only matrix. While the differentiation of circulating progenitor cells to CD31+ cells was equal on all matrices, vascular endothelial-cadherin expression was increased on the collagen–chitosan matrix, suggesting greater maturation of the endothelial cells. In addition, the collagen–chitosan matrix supported a significantly greater number of CD133+ progenitor cells than the collagen-only matrix. In vivo, subcutaneously implanted collagen–chitosan matrices stimulated greater vascular growth and recruited more von Willebrand factor (vWF+) and CXCR4+ endothelial/angiogenic cells than the collagen-only matrix. These results indicate that the addition of chitosan can improve the physical properties of collagen matrices, and enhance their ability to support endothelial cells and angiogenesis for use in cardiovascular tissue engineering applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Current research on the blends of natural and synthetic polymers as new biomaterials: Review
Sionkowska, A. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.05.003 · Cited by 970
Biopolymers for hydrogels in cosmetics: review
Mitura, S., Sionkowska, A., & Jaiswal, A. (2020) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-020-06390-w · Cited by 314
Hutson, C. B., Nichol, J. W., Aubin, H., Bae, H., Yamanlar, S., Al-Haque, S., Koshy, S. T., & Khademhosseini, A. (2011) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0666 · Cited by 303
Fagerholm, P., Lagali, N. S., Ong, J. A., Merrett, K., Jackson, W. B., Polarek, J. W., Suuronen, E. J., Liu, Y., Brunette, I., & Griffith, M. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.079 · Cited by 299
Self-citationSpecialty Tough Hydrogels and Their Biomedical Applications
Fuchs, S., Shariati, K., & Ma, M. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901396 · Cited by 279
Chitosan-based blends for biomedical applications
Seidi, F., Khodadadi Yazdi, M., Jouyandeh, M., Dominic, M., Naeim, H., Nezhad, M. N., Bagheri, B., Habibzadeh, S., Zarrintaj, P., Saeb, M. R., et al. (2021) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2021.05.003 · Cited by 199
Metadata
- Authors
- Deng, C., Zhang, P., Vulesevic, B., Kuraitis, D., Li, F., Yang, A. F., Griffith, M., Ruel, M., & Suuronen, E. J.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2010-10
- Volume
- 16
- Issue
- 10
- Pages
- 3099-3109
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W1963904462
- Cited by
- 164
- References
- 0
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.