The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Correlation Between the Internal Structure and Vascularization of Controllable Porous Bioceramic Materials In Vivo : A Quantitative Study
Abstract
It is noticeable that porous architectural characteristics of the biomaterials play an important role in revascularization of the scaffold. However, there has been no consensus regarding the optimal conditions for vascularization, including macropore size, shape, interconnection, and the arrangement of macropores, due to the failure to accurately control porous structure of biomaterials. To investigate the effect of the porous structure parameters on vascularization of the biomaterials, an accurate control of these parameters is required. In this study, porous β-tricalcium phosphate (β-TCP) with accurately controlled pore parameters is fabricated by using assembled organic microspheres as templates combined with casting technique. Using this technique, we produced a series of disk-type β-TCP with variable pore sizes and variable interconnections to evaluate the influence of macropore size and interconnection on the vascularization of bioceramic material in vivo. The vascularization of β-TCP implanted in the rabbit model is evaluated by histomorphology and single photon emission computed tomography. The results showed that the pore parameters affect not only the size of the blood vessels growing into the porous structure but also the number of blood vessels formed in the pores of the bioceramic. The increase in pore size only resulted in an increase in size of the blood vessels growing into the macroporous of the bioceramic scaffolds. However, with the increase in size of interconnection, both the size and number of the blood vessels formed in the macroporous increased. Therefore, we conclude that the size of the interconnections is more important for vascularization in the scaffold compared with the pore size. On the other hand, there was no significant difference in vascularization in the scaffolds with pores size above 400 μm, and there was no marked increase in extent of vascularization with further increase in pore size above 400 μm, indicating that the upper limit of pore size for vascularization is 400 μm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Cited by
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
Bone grafts and biomaterials substitutes for bone defect repair: A review
Wang, W., & Yeung, K. W. K. (2017) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.05.007 · Cited by 1,938
Taniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
Biofabrication of bone tissue: approaches, challenges and translation for bone regeneration
Tang, D., Tare, R. S., Yang, L.-Y., Williams, D. F., Ou, K.-L., & Oreffo, R. O. C. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.024 · Cited by 613
Bone tissue regeneration: the role of scaffold geometry
Zadpoor, A. A. (2015) · Biomaterials Science · doi:10.1039/c4bm00291a · Cited by 518
Metadata
- Authors
- Bai, F., Wang, Z., Lu, J., Liu, J., Chen, G., Lv, R., Wang, J., Lin, K., Zhang, J., & Huang, X.
- Venue
- Tissue Engineering Part A
- Publisher
- SAGE Publications
- Published
- 2010-12
- Volume
- 16
- Issue
- 12
- Pages
- 3791-3803
- ISSN
- 1937-3341 (ISSN-L)
- 1937-335X
- OpenAlex
- W2157514082
- Cited by
- 184
- References
- 1
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.