CoChat

Spontaneous Formation of Extensive Vessel-Like Structures in Murine Engineered Heart Tissue

Open access
Stoehr, Andrea, Hirt, Marc N., Hansen, Arne, Seiffert, Moritz, Conradi, Lenard, Uebeler, June, Limbourg, Florian P., Eschenhagen, Thomas · 2016 · Tissue Engineering Part A
Cited by 20

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Engineered heart tissue (EHT) from primary heart cells contains endothelial cells (ECs), but the extent to which ECs organize into vessel-like structures or even functional vessels remains unknown and is difficult to study by conventional methods. In this study, we generated fibrin-based mini-EHTs from a transgenic mouse line (Cdh5-CreERT2 × Rosa26-LacZ), in which ECs were specifically and inducibly labeled by applying tamoxifen (EC iLacZ ). EHTs were generated from an unpurified cell mix of newborn mouse hearts and were cultured under standard serum-containing conditions. Cre expression in 15-day-old EHTs was induced by addition of o- hydroxytamoxifen to the culture medium for 48 h, and ECs were visualized by X-gal staining. EC iLacZ EHTs showed a dense X-gal-positive vessel-like network with distinct tubular structures. Immunofluorescence revealed that ECs were mainly associated with cardiomyocytes within the EHT. EC iLacZ EHT developed spontaneous and regular contractility with forces up to 0.1 mN. Coherent contractility and the presence of an extensive vessel-like network were both dependent on the presence of animal sera in the culture medium. Contractile EC iLacZ EHTs successfully served as grafts in implantation studies onto the hearts of immunodeficient mice. Four weeks after implantation, EHTs showed X-gal-positive lumen-forming vessel structures connected to the host myocardium circulation as they contained erythrocytes on a regular basis. Taken together, genetic labeling of ECs revealed the extensive formation of vessel-like structures in EHTs in vitro . The EC iLacZ EHT model could help simultaneously study biological effects of compounds on cardiomyocyte function and tissue vascularization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tea.2015.0242

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 20

Metadata

Authors
Stoehr, A., Hirt, M. N., Hansen, A., Seiffert, M., Conradi, L., Uebeler, J., Limbourg, F. P., & Eschenhagen, T.
Venue
Tissue Engineering Part A
Published
2016-01-29
Volume
22
Issue
3-4
Pages
326-335
ISSN
  • 1937-3341 (ISSN-L)
  • 1937-335X
OpenAlex
W2235531526
Cited by
20
References
4
FWCI
4.65
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.