Engineering Bi-Layer Nanofibrous Conduits for Peripheral Nerve Regeneration
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Trauma injuries often cause peripheral nerve damage and disability. A goal in neural tissue engineering is to develop synthetic nerve conduits for peripheral nerve regeneration having therapeutic efficacy comparable to that of autografts. Nanofibrous conduits with aligned nanofibers have been shown to promote nerve regeneration, but current fabrication methods rely on rolling a fibrous sheet into the shape of a conduit, which results in a graft with inconsistent size and a discontinuous joint or seam. In addition, the long-term effects of nanofibrous nerve conduits, in comparison with autografts, are still unknown. Here we developed a novel one-step electrospinning process and, for the first time, fabricated a seamless bi-layer nanofibrous nerve conduit: the luminal layer having longitudinally aligned nanofibers to promote nerve regeneration, and the outer layer having randomly organized nanofibers for mechanical support. Long-term in vivo studies demonstrated that bi-layer aligned nanofibrous nerve conduits were superior to random nanofibrous conduits and had comparable therapeutic effects to autografts for nerve regeneration. In summary, we showed that the engineered nanostructure had a significant impact on neural tissue regeneration in situ. The results from this study will also lead to the scalable fabrication of engineered nanofibrous nerve conduits with designed nanostructure. This technology platform can be combined with drug delivery and cell therapies for tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cao, H., Mchugh, K., Chew, S. Y., & Anderson, J. M. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32609 · Cited by 243
Cited by
Vijayavenkataraman, S. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.02.003 · Cited by 556
Electrospun Nanofibers for Regenerative Medicine
Liu, W., Thomopoulos, S., & Xia, Y. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201100021 · Cited by 550
Differentiation of multipotent vascular stem cells contributes to vascular diseases
Tang, Z., Wang, A., Yuan, F., Yan, Z., Liu, B., Chu, J. S., Helms, J. A., & Li, S. (2012) · Nature Communications · doi:10.1038/ncomms1867 · Cited by 292
Self-citationTrends in the design of nerve guidance channels in peripheral nerve tissue engineering
Chiono, V., & Tonda-Turo, C. (2015) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2015.06.001 · Cited by 290
Induced pluripotent stem cells for neural tissue engineering
Wang, A., Tang, Z., Park, I.-H., Zhu, Y., Patel, S., Daley, G. Q., & Li, S. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.03.070 · Cited by 255
Self-citation
Metadata
- Authors
- Zhu, Y., Wang, A., Patel, S., Kurpinski, K., Diao, E., Bao, X., Kwong, G., Young, W. L., & Li, S.
- Venue
- Tissue Engineering Part C: Methods
- Publisher
- SAGE Publications
- Published
- 2011-07
- Volume
- 17
- Issue
- 7
- Pages
- 705-715
- ISSN
- 1937-3384 (ISSN-L)
- 1937-3392
- OpenAlex
- W2074895254
- Cited by
- 98
- References
- 1
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.