Hyaluronic Acid Coating Enhances Biocompatibility of Nonwoven PGA Scaffold and Cartilage Formation
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Synthetic polymers such as polyglycolic acid (PGA) fibers are the traditional tissue engineering scaffolds that are widely used for engineering a variety of soft tissues. However, the major disadvantage of this polymer material is its released acidic degradation products that trigger inflammatory response and fibrotic process, which affects the biocompatibility and the quality of the engineered tissues. In this study, the effect of hyaluronic acid (HA) coating on improving PGA biocompatibility was explored. The results showed that 1% HA solution could better coat PGA fibers than other tested concentrations of HA, and coated PGA exhibited less inflammatory reaction upon in vivo subcutaneous implantation. In vitro characterization demonstrated that HA coating could enhance cell adhesion to the scaffold and reduce gene expression of IL-1, IL-6, IL-8, and α-SMA. It also decreased the acidity of degradation products in vitro. Furthermore, coated PGA could engineer better cartilages in vitro with higher content of total collagen and glycosaminoglycan, as well as higher gene expression levels of collagen II, aggrecan, and Sox9. Collectively, the data indicate that HA coating can significantly enhance the biocompatibility of this traditional scaffold material, which also enhances the quality of engineered tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Tissue engineering of blood vessel
Zhang, W. J., Liu, W., Cui, L., & Cao, Y. (2007) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2007.00099.x · Cited by 217
Self-citation
Cited by
Samantaray, P. K., Little, A., Haddleton, D. M., McNally, T., Tan, B., Sun, Z., Huang, W., Ji, Y., & Wan, C. (2020) · Green Chemistry · doi:10.1039/d0gc01394c · Cited by 450
Qi, C., Liu, J., Jin, Y., Xu, L., Wang, G., Wang, Z., & Wang, L. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.02.016 · Cited by 248
Biocompatible Synthetic Polymers for Tissue Engineering Purposes
Terzopoulou, Z., Zamboulis, A., Koumentakou, I., Michailidou, G., Noordam, M. J., & Bikiaris, D. N. (2022) · Biomacromolecules · doi:10.1021/acs.biomac.2c00047 · Cited by 230
Polysaccharide Based Scaffolds for Soft Tissue Engineering Applications
Tiwari, S., Patil, R., & Bahadur, P. (2018) · Polymers · doi:10.3390/polym11010001 · Cited by 183
“Material safety has been evaluated in animal models to verify that unseeded scaffold does not induce cell infiltration or aberrant histological changes in the neighboring tissues [39].”
BackgroundElectrospun acid-neutralizing fibers for the amelioration of inflammatory response
Shen, Y., Tu, T., Yi, B., Wang, X., Tang, H., Liu, W., & Zhang, Y. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.014 · Cited by 87
Self-citation
Metadata
- Authors
- Lin, X., Wang, W., Zhang, W., Zhang, Z., Zhou, G., Cao, Y., & Liu, W.
- Venue
- Tissue Engineering Part C: Methods
- Publisher
- SAGE Publications
- Published
- 2017-02
- Volume
- 23
- Issue
- 2
- Pages
- 86-97
- ISSN
- 1937-3384 (ISSN-L)
- 1937-3392
- OpenAlex
- W2603748904
- Cited by
- 45
- References
- 2
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hyaluronic Acid Coating Enhances Biocompatibility of Nonwoven PGA Scaffold and Cartilage Formation. https://app.cochat.ai/papers/10.1089/ten.tec.2016.0373
- The paper
- Lin, X., Wang, W., Zhang, W., Zhang, Z., Zhou, G., Cao, Y., & Liu, W. (2017). Hyaluronic Acid Coating Enhances Biocompatibility of Nonwoven PGA Scaffold and Cartilage Formation. Tissue Engineering Part C: Methods. https://doi.org/10.1089/ten.tec.2016.0373
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.