A Randomized Controlled Trial Comparing Health and Quality of Life of Lung Transplant Recipients Following Nurse and Computer-Based Triage Utilizing Home Spirometry Monitoring
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Lung transplantation is now a standard intervention for patients with advanced lung disease. Home monitoring of pulmonary function and symptoms has been used to follow the progress of lung transplant recipients in an effort to improve care and clinical status. The study objective was to determine the relative performance of a computer-based Bayesian algorithm compared with a manual nurse decision process for triaging clinical intervention in lung transplant recipients participating in a home monitoring program. MATERIALS AND METHODS: This randomized controlled trial had 65 lung transplant recipients assigned to either the Bayesian or nurse triage study arm. Subjects monitored and transmitted spirometry and respiratory symptoms daily to the data center using an electronic spirometer/diary device. Subjects completed the Short Form-36 (SF-36) survey at baseline and after 1 year. End points were change from baseline after 1 year in forced expiratory volume at 1 s (FEV1) and quality of life (SF-36 scales) within and between each study arm. RESULTS: There were no statistically significant differences between groups in FEV1 or SF-36 scales at baseline or after 1 year.: Results were comparable between nurse and Bayesian system for detecting changes in spirometry and symptoms, providing support for using computer-based triage support systems as remote monitoring triage programs become more widely available. CONCLUSIONS: The feasibility of monitoring critical patient data with a computer-based decision system is especially important given the likely economic constraints on the growth in the nurse workforce capable of providing these early detection triage services.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Christie, J. D., Edwards, L. B., Kucheryavaya, A. Y., Benden, C., Dipchand, A. I., Dobbels, F., Kirk, R., Rahmel, A. O., Stehlik, J., & Hertz, M. I. (2012) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2012.08.004 · Cited by 630
Self-citationEuropean Society of Hypertension Practice Guidelines for home blood pressure monitoring
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.54 · Cited by 482 · cited 1×
“13 Home monitoring (HM) has been used in a range of clinical contexts, including chronic diseases like hypertension 14,15 and diabetes.”
Research works printed but not linked: 32
- 10.1159/000195966 · DOI
- 10.1183/09031936.93.03050594 · doi:10.1183/09031936.93.03050594
- 10.1016/0140-6736(92)91842-V · doi:10.1016/0140-6736(92)91842-v
- 10.1161/01.CIR.84.6.2275 · doi:10.1161/01.cir.84.6.2275
- 10.1378/chest.96.4.738 · doi:10.1378/chest.96.4.738
- 10.1183/09031936.93.06050705 · DOI · Paper page
- Fracchia C, , Callegari G, , Volpato G et al. Monitoring of lung rejection with home spirometry. Transplant Proc, 1995; 27:2000–2001.
- 10.1164/ajrccm.165.5.2107059 · DOI · Paper page
- 10.1378/chest.97.2.353 · DOI
- 10.1016/S0003-4975(99)01140-6 · DOI
- Finkelstein SM, , Lindgren B, , Prasad B, , Snyder M, , Edin C, , Wielinski CL et al. Reliability and validity of spirometry measurements in a paperless home monitoring diary program for lung transplantation. Heart Lung, 1993; 22:523–533.
- 10.1097/01.JCN.0000317429.98844.04 · DOI · Paper page
- 10.1177/193229681100500638 · DOI
- 10.1136/jamia.2002.0090049 · DOI · Paper page
- 10.3109/03091909609008999 · DOI · Paper page
- 10.1002/(SICI)1098-240X(199712)20:6<539::AID-NUR8>3.0.CO;2-N · DOI · Paper page
- 10.1017/S0266462307070080 · doi:10.1017/s0266462307070080
- 10.1089/tmj.2009.0148 · DOI
- 10.1183/09031936.05.00034805 · DOI · Paper page
- Karnofsky DA, , Burchanot JH. The clinical evaluation of chemotherapeutic agents. New York: Columbia University Press, 1949.
- 10.1016/j.hrtlng.2004.09.003 · DOI
- 10.1002/sim.1651 · DOI
- 10.1097/00005650-199206000-00002 · DOI · Paper page
- 10.1093/geront/36.5.571 · DOI · Paper page
- 10.1097/00005650-199303000-00006 · DOI · Paper page
- 10.1016/j.healun.2004.04.012 · DOI
- Beilby S, , Moss-Morris R, , Painter L. Quality of life before and after heart, lung and liver transplantation. N Z Med J, 2003; 116:381–388.
- 10.1016/j.healun.2003.12.013 · DOI
- Somoza KC, , Momtahan K, , Linfgaard G. Effects of a computerized cardiac teletriage decision support system on nurse performance: Results of a controlled human factors experiment using a mid-fidelity prototype. Stud Health Technol Inform, 2007; 129:97–101.
- 10.1197/j.aem.2005.01.005 · DOI
- 10.1016/j.ijmedinf.2005.07.028 · DOI
- 10.1097/MOP.0b013e328338da83 · doi:10.1097/mop.0b013e328338da83
Cited by
Khosravi, M., Zare, Z., Mojtabaeian, S. M., & Izadi, R. (2024) · Health Services Research and Managerial Epidemiology · doi:10.1177/23333928241234863 · Cited by 265
Zhou, Q., Chen, Z.-H., Cao, Y.-H., & Peng, S. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00524-2 · Cited by 126
DeVito Dabbs, A., Song, M. K., Myers, B. A., Li, R., Hawkins, R. P., Pilewski, J. M., Bermudez, C. A., Aubrecht, J., Begey, A., Connolly, M., et al. (2016) · American Journal of Transplantation · doi:10.1111/ajt.13701 · Cited by 120
Cresswell, K., Callaghan, M., Khan, S., Sheikh, Z., Mozaffar, H., & Sheikh, A. (2020) · Health Informatics Journal · doi:10.1177/1460458219900452 · Cited by 87
Metadata
- Authors
- Finkelstein, S. M., Lindgren, B. R., Robiner, W., Lindquist, R., Hertz, M., Carlin, B. P., & VanWormer, A.
- Venue
- Telemedicine and e-Health
- Publisher
- SAGE Publications
- Published
- 2013-12
- Volume
- 19
- Issue
- 12
- Pages
- 897-903
- ISSN
- 1530-5627 (ISSN-L)
- 1556-3669
- OpenAlex
- W2062530742
- Cited by
- 37
- References
- 2
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Randomized Controlled Trial Comparing Health and Quality of Life of Lung Transplant Recipients Following Nurse and Computer-Based Triage Utilizing Home Spirometry Monitoring. https://app.cochat.ai/papers/10.1089/tmj.2013.0049
- The paper
- Finkelstein, S. M., Lindgren, B. R., Robiner, W., Lindquist, R., Hertz, M., Carlin, B. P., & VanWormer, A. (2013). A Randomized Controlled Trial Comparing Health and Quality of Life of Lung Transplant Recipients Following Nurse and Computer-Based Triage Utilizing Home Spirometry Monitoring. Telemedicine and e-Health. https://doi.org/10.1089/tmj.2013.0049
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.