Wireless Vital Sign Monitoring in Pregnant Women: A Functionality and Acceptability Study

Boatin, Adeline Adwoa, Wylie, Blair Johnson, Goldfarb, Ilona, Azevedo, Robin, Pittel, Elena, Ng, Courtney, Haberer, Jessica Elizabeth·2016·Telemedicine and e-Health

Abstract

Objective: To test the functionality and acceptability of a wireless vital sign monitor in an inpatient obstetric unit. Materials and Methods: Pregnant women at a U.S. tertiary-care hospital wore a wireless vital sign sensor that captures heart rate, respiratory rate, and temperature. Measurements were compared with vital signs obtained by standard devices. We defined continuous capture of vital signs for 30 min with wireless data transfer to a central monitor as functional success. Acceptability was assessed per the pregnant women and nurses observing the device. Bland–Altman plots were constructed to assess agreement between the wireless sensor and standard measurements. Results: Thirty of 32 enrolled pregnant women had successful monitoring; 2 cases were stopped early for non–study-related reasons. Comparing wireless sensor and standard measurements, the mean difference (limits of agreement) values at the 25th and 75th percentiles were 1.6 (±13.2) and 4.2 (±18.6) heartbeats/min, 4.2 (±6.1) and 0.7 (±5.4) respirations/min, and 0.02°C (±1.5) and 0.5°C (±1.8), respectively. Most pregnant women found the device comfortable, likeable, and useful (78%, 81%, and 97%, respectively); 80% of nurses found the monitor easy to use, and 84% would recommend it to a patient. Conclusions: We successfully obtained maternal vital signs using a simple wireless monitor with high acceptability. Well-validated monitors of this nature could significantly alleviate the human resource burden of monitoring during labor and confer greatly desired mobility to laboring pregnant women, although incorporation of blood pressure monitoring will be critical.

Integrity signals

Registry

Crossref · 10.1089/tmj.2015.0173

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Additional monitoring equipment designed to assess maternal or fetal status, such as pulse oximetry, blood pressure monitors, and electrocardiography, are typically used in a noncontinuous manner and place a relatively high burden on providers.

    “Additional monitoring equipment designed to assess maternal or fetal status, such as pulse oximetry, blood pressure (BP) monitors, and electrocardiography (ECG), are typically used in a noncontinuous manner and place a relatively high burden on providers (11).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Boatin, A. A., Wylie, B. J., Goldfarb, I., Azevedo, R., Pittel, E., Ng, C., & Haberer, J. E.
Affiliations
  • Harvard University (US)
  • Massachusetts General Hospital (US)
Corresponding author
Boatin, Adeline Adwoa
Venue
Telemedicine and e-Health
Published
2016-07
Volume
22
Issue
7
Pages
564-571
ISSN
  • 1530-5627 (ISSN-L)
  • 1556-3669
OpenAlex
W2349429054
Cited by
30
References
25
Citations by year
2024: 4 · 2023: 5 · 2022: 4 · 2021: 5 · 2020: 4 · 2019: 1 · 2018: 2 · 2017: 3 · 2016: 1
FWCI
1.12
Type
journal article
Language
en
Open access
closed
Locations
  • Telemedicine Journal and e-Health (publishedVersion)
  • PubMed (publishedVersion)
Funders
Massachusetts General Hospital
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
pregnant women, heart rate, respiratory rate, body temperature, device acceptability, sensor accuracy, labor monitoring, nurses' perceptions, patient comfort
MeSH terms
Adolescent, Adult, Cross-Sectional Studies, Female, Humans, Pregnancy, United States, Patient Satisfaction, Young Adult, Vital Signs, Remote Sensing Technology, Wireless Technology, Tertiary Care Centers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review