CoChat

Diagnostic accuracy of the 4AT for delirium detection in older adults: systematic review and meta-analysis

Open access
Tieges, Zoë, Maclullich, Alasdair M J, Anand, Atul, Brookes, Claire, Cassarino, Marica, O’connor, Margaret, Ryan, Damien, Saller, Thomas, Arora, Rakesh C, Chang, Yue, Agarwal, Kathryn, Taffet, George, Quinn, Terence, Shenkin, Susan D, Galvin, Rose · 2021 · Age and Ageing
Cited by 233

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Objective: Detection of delirium in hospitalised older adults is recommended in national and international guidelines. The 4 ‘A’s Test (4AT) is a short (<2 minutes) instrument for delirium detection that is used internationally as a standard tool in clinical practice. We performed a systematic review and meta-analysis of diagnostic test accuracy of the 4AT for delirium detection. Methods: We searched MEDLINE, EMBASE, PsycINFO, CINAHL, clinicaltrials.gov and the Cochrane Central Register of Controlled Trials, from 2011 (year of 4AT release on the website www.the4AT.com) until 21 December 2019. Inclusion criteria were: older adults (≥65 years); diagnostic accuracy study of the 4AT index test when compared to delirium reference standard (standard diagnostic criteria or validated tool). Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Pooled estimates of sensitivity and specificity were generated from a bivariate random effects model. Results: Seventeen studies (3,702 observations) were included. Settings were acute medicine, surgery, a care home and the emergency department. Three studies assessed performance of the 4AT in stroke. The overall prevalence of delirium was 24.2% (95% CI 17.8–32.1%; range 10.5–61.9%). The pooled sensitivity was 0.88 (95% CI 0.80–0.93) and the pooled specificity was 0.88 (95% CI 0.82–0.92). Excluding the stroke studies, the pooled sensitivity was 0.86 (95% CI 0.77–0.92) and the pooled specificity was 0.89 (95% CI 0.83–0.93). The methodological quality of studies varied but was moderate to good overall. Conclusions: The 4AT shows good diagnostic test accuracy for delirium in the 17 available studies. These findings support its use in routine clinical practice in delirium detection. PROSPERO Registration number: CRD42019133702.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ageing/afaa224

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

  • Delirium

    Wilson, J. E., Mart, M. F., Cunningham, C., Shehabi, Y., Girard, T. D., MacLullich, A. M. J., Slooter, A. J. C., & Ely, E. W. (2020) · Nature Reviews Disease Primers · doi:10.1038/s41572-020-00223-4 · Cited by 1,200

    Self-citation

See all 233

Metadata

Authors
Tieges, Z., Maclullich, A. M. J., Anand, A., Brookes, C., Cassarino, M., O’connor, M., Ryan, D., Saller, T., Arora, R. C., Chang, Y., Agarwal, K., Taffet, G., Quinn, T., Shenkin, S. D., & Galvin, R.
Venue
Age and Ageing
Published
2020-11-11
Volume
50
Issue
3
Pages
733-743
ISSN
  • 0002-0729 (ISSN-L)
  • 1468-2834
OpenAlex
W3087620222
Cited by
233
References
5
FWCI
4.97
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.