Detection of falls using accelerometers and mobile phone technology
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: to study the sensitivity and specificity of fall detection using mobile phone technology. DESIGN: an experimental investigation using motion signals detected by the mobile phone. SETTING AND PARTICIPANTS: the research was conducted in a laboratory setting, and 18 healthy adults (12 males and 6 females; age = 29 ± 8.7 years) were recruited. MEASUREMENT: each participant was requested to perform three trials of four different types of simulated falls (forwards, backwards, lateral left and lateral right) and eight other everyday activities (sit-to-stand, stand-to-sit, level walking, walking up- and downstairs, answering the phone, picking up an object and getting up from supine). Acceleration was measured using two devices, a mobile phone and an independent accelerometer attached to the waist of the participants. RESULTS: Bland-Altman analysis shows a higher degree of agreement between the data recorded by the two devices. Using individual upper and lower detection thresholds, the specificity and sensitivity for mobile phone were 0.81 and 0.77, respectively, and for external accelerometer they were 0.82 and 0.96, respectively. CONCLUSION: fall detection using a mobile phone is a feasible and highly attractive technology for older adults, especially those living alone. It may be best achieved with an accelerometer attached to the waist, which transmits signals wirelessly to a phone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058 · cited 1×
“The waist was selected as it has been found to be a suitable position for accelerometer-based fall detection [26].”
Talbot, L. A., Musiol, R. J., Witham, E. K., & Metter, E. J. (2005) · BMC Public Health · doi:10.1186/1471-2458-5-86 · Cited by 654
A wearable system for pre-impact fall detection
Nyan, M. N., Tay, F. E. H., & Murugasu, E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.009 · Cited by 241
Cited by
Challenges, issues and trends in fall detection systems
Igual, R., Medrano, C., & Plaza, I. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-66 · Cited by 654
Evaluation of Accelerometer-Based Fall Detection Algorithms on Real-World Falls
Bagalà, F., Becker, C., Cappello, A., Chiari, L., Aminian, K., Hausdorff, J. M., Zijlstra, W., & Klenk, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037062 · Cited by 464
Review of fall risk assessment in geriatric populations using inertial sensors
Howcroft, J., Kofman, J., & Lemaire, E. D. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-91 · Cited by 377
Detecting Falls with Wearable Sensors Using Machine Learning Techniques
Özdemir, A., & Barshan, B. (2014) · Sensors · doi:10.3390/s140610691 · Cited by 375
Fall Detection Devices and Their Use With Older Adults: A Systematic Review
Chaudhuri, S., Thompson, H., & Demiris, G. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe779 · Cited by 215
Metadata
- Authors
- Lee, R. Y. W., & Carlisle, A. J.
- Venue
- Age and Ageing
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-05-19
- Volume
- 40
- Issue
- 6
- Pages
- 690-696
- ISSN
- 0002-0729 (ISSN-L)
- 1468-2834
- OpenAlex
- W2118157558
- Cited by
- 141
- References
- 3
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of falls using accelerometers and mobile phone technology. https://app.cochat.ai/papers/10.1093/ageing/afr050
- The paper
- Lee, R. Y. W., & Carlisle, A. J. (2011). Detection of falls using accelerometers and mobile phone technology. Age and Ageing. https://doi.org/10.1093/ageing/afr050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.