Inflammatory Responses to Biomaterials
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Implanted biomedical devices are of increasing importance in modern medical care. However, surprisingly little is known of the factors that determine biocompatibility of the materials used in these devices. These materials, although generally inert and non-toxic, can mediate a variety of adverse reactions, including inflammation, fibrosis, coagulation, and infection. This brief review focuses on the inflammatory responses (including fibrosis) that commonly occur around implanted biomaterials. Host proteins that spontaneously associate with implant surfaces are important determinants of the acute inflammatory response. In this regard, adsorbed fibrinogen appears particularly pro-inflammatory. Chronic inflammatory processes, in many cases in response to fragments of implanted biomaterials, may cause implant failure. In the case of silicone-filled mammary prostheses, the extravasation of silicone gel has been held responsible for a number of complications, including silicone granuloma, synovitis, connective-tissue disease, and lymphadenopathy. In some instances, material-mediated inflammatory responses may even cause degradation of the material itself (via oxidative products released by implant-associated inflammatory cells). Overall, there is insufficient knowledge of the determinants and mechanisms of host: implant responses. A clear understanding of tissue:biomaterial interactions will be required both to explain the pathogenesis of many implant-mediated complications and to aid in the development of more biocompatible materials for implantable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Craddock, P. R., Fehr, J., Dalmasso, A. P., Brighan, K. L., & Jacob, H. S. (1977) · Journal of Clinical Investigation · doi:10.1172/jci108710 · Cited by 991
Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365050-00001 · Cited by 849
Reactions of the articular capsule to wear products of artificial joint prostheses
Willert, H. ‐., & Semlitsch, M. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110202 · Cited by 822
Ten-year follow-up study of total hip replacement.
Stauffer, R. N. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264070-00003 · Cited by 639
The initiation of failure in cemented femoral components of hip arthroplasties
Jasty, M., Maloney, W. J., Bragdon, C. R., O'Connor, D., Haire, T., & Wh, H. (1991) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.73b4.2071634 · Cited by 561
Structural changes in proteins adsorbed on polymer surfaces
Soderquist, M. E., & Walton, A. G. (1980) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(80)90463-4 · Cited by 451
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.
Tang, L., & Eaton, J. W. (1993) · The Journal of experimental medicine · doi:10.1084/jem.178.6.2147 · Cited by 449
Self-citationInitial events in interactions of blood with a foreign surface
Baier, R. E., & Dutton, R. C. (1969) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820030115 · Cited by 448
Risk of Connective-Tissue Diseases and Other Disorders after Breast Implantation
Gabriel, S. E., O'Fallon, W. M., Kurland, L. T., Beard, C. M., Woods, J. E., & Melton, L. J. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406163302401 · Cited by 427
Macrophages stimulate bone resorption when they phagocytose particles
Murray, D., & Rushton, N. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b6.2246303 · Cited by 402
Cited by
Mesoporous Materials for Drug Delivery
Vallet‐Regí, M., Balas, F., & Arcos, D. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604488 · Cited by 2,507
Corrosion of Metallic Biomaterials: A Review
Eliaz, N. (2019) · Materials · doi:10.3390/ma12030407 · Cited by 984
Alginate-based microcapsules for immunoisolation of pancreatic islets
de Vos, P., Faas, M. M., Strand, B., & Calafiore, R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.010 · Cited by 511
Implant infections: a haven for opportunistic bacteria
Schierholz, J. M., & Beuth, J. (2001) · Journal of Hospital Infection · doi:10.1053/jhin.2001.1052 · Cited by 509
The application of hyaluronic acid in bone regeneration
Zhai, P., Peng, X., Li, B., Liu, Y., Sun, H., & Li, X. (2020) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.10.169 · Cited by 438
Osteopontin Inhibits Mineral Deposition and Promotes Regression of Ectopic Calcification
Steitz, S. A., Speer, M. Y., McKee, M. D., Liaw, L., Almeida, M., Yang, H., & Giachelli, C. M. (2002) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64482-3 · Cited by 422
Targeting dendritic cells with biomaterials: developing the next generation of vaccines
Reddy, S. T., Swartz, M. A., & Hubbell, J. A. (2006) · Trends in Immunology · doi:10.1016/j.it.2006.10.005 · Cited by 406
Biological responses to physicochemical properties of biomaterial surface
Rahmati, M., Silva, E. A., Reseland, J. E., A. Heyward, C., & Haugen, H. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00103a · Cited by 391
Biofilm formation, bacterial adhesion and host response on polymeric implants—issues and prevention
Pavithra, D., & Doble, M. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034003 · Cited by 371
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Biocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility
Fournier, E., Passirani, C., Montero-Menei, C. N., & Benoit, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00161-3 · Cited by 353
Adverse Reactions to Injectable Soft Tissue Permanent Fillers
Christensen, L., Breiting, V., Janssen, M., Vuust, J., & Hogdall, E. (2005) · Aesthetic Plastic Surgery · doi:10.1007/s00266-004-0113-6 · Cited by 326
Peng, X., Xia, X., Xu, X., Yang, X., Yang, B., Zhao, P., Yuan, W., Chiu, P. W. Y., & Bian, L. (2021) · Science Advances · doi:10.1126/sciadv.abe8739 · Cited by 305
Kyriakides, T. R., Foster, M. J., Keeney, G. E., Tsai, A., Giachelli, C. M., Clark-Lewis, I., Rollins, B. J., & Bornstein, P. (2004) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63265-8 · Cited by 226
Understanding interactions between biomaterials and biological systems using proteomics
Othman, Z., Cillero Pastor, B., van Rijt, S., & Habibovic, P. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.03.020 · Cited by 202
“Therefore, the body's response to the implants are determined mostly by the extent and nature of the initial protein adsorption [47,48].”
BackgroundResultInfluentialZdolsek, J., Eaton, J. W., & Tang, L. (2007) · Journal of Translational Medicine · doi:10.1186/1479-5876-5-31 · Cited by 154
Self-citationKawamura, T., Miyagawa, S., Fukushima, S., Maeda, A., Kashiyama, N., Kawamura, A., Miki, K., Okita, K., Yoshida, Y., Shiina, T., et al. (2016) · Stem Cell Reports · doi:10.1016/j.stemcr.2016.01.012 · Cited by 145
“For these approaches, the establishment of iPSC lines from healthy donors with homozygous MHC alleles is useful for minimizing the number of banked iPSC lines (Nakatsuji et al., 2008; Taylor et al., 2012).”
BackgroundImplantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Cellular Plasticity of Inflammatory Myeloid Cells in the Peritoneal Foreign Body Response
Mooney, J. E., Rolfe, B. E., Osborne, G. W., Sester, D. P., van Rooijen, N., Campbell, G. R., Hume, D. A., & Campbell, J. H. (2010) · The American Journal of Pathology · doi:10.2353/ajpath.2010.090545 · Cited by 87
The role of osteopontin in foreign body giant cell formation
Tsai, A. T., Rice, J., Scatena, M., Liaw, L., Ratner, B. D., & Giachelli, C. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.03.003 · Cited by 71
Fibroblasts: Diverse Cells Critical to Biomaterials Integration
Hannan, R. T., Peirce, S. M., & Barker, T. H. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00244 · Cited by 59
Zhou, G., Niepel, M. S., Saretia, S., & Groth, T. (2016) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35587 · Cited by 55
Biomaterials-Driven Sterile Inflammation
Chen, H., Agrawal, D. K., & Thankam, F. G. (2022) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2020.0253 · Cited by 41
Ravin, A. G., Olbrich, K. C., Levin, L. S., Usala, A.-L., & Klitzman, B. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(2001)58:3<313::aid-jbm1023>3.0.co;2-o · Cited by 41
Mesure, L., De Visscher, G., Vranken, I., Lebacq, A., & Flameng, W. (2010) · PLoS ONE · doi:10.1371/journal.pone.0012949 · Cited by 40
“initiated by the adhesion and denaturation of fibrinogen (FG) [4]”
BackgroundClausen, T. S., Kaastrup, P., & Stallknecht, B. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0058 · Cited by 36
Alkhoury, H., Hautmann, A., Fuhrmann, B., Syrowatka, F., Erdmann, F., Zhou, G., Stojanović, S., Najman, S., & Groth, T. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21103724 · Cited by 30
Metadata
- Authors
- Tang, L., & Eaton, J. W.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-04-01
- Volume
- 103
- Issue
- 4
- Pages
- 466-471
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W2229049611
- Cited by
- 481
- References
- 44
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.