The Accuracy and Performance of the A&D TM 2421, a New Ambulatory Blood Pressure Monitoring Device Based on the Cuff-Oscillometric Method and the Korotkoff Sound Technique
The DOI matches its Crossref record.
Abstract
The accuracy and performance of the A&D TM 2421, a new ambulatory blood pressure (BP) monitoring device using both the cuff-oscillometric method (O) and the Korotkoffsound method (K) were evaluated. The device was tested for accuracy under static and dynamic conditions by simultaneous comparison with two observers using a standard mercury column sphygmomanometer (standard method) and by the objective recording method (ORM). The performance of the device was also evaluated under ordinary ambulatory conditions. The mean differences in BP of standard method from K-method were −1.2 ± 4.7 mm Hg systole and 1.3 ± 4.7 mm Hg diastole (n = 323, mean ± SD) and those of standard method from Omethod were −0.4 ± 5.3 mm Hg systole and 1.4 ± 5.1 mm Hg diastole (n = 323). The agreement between each of the two methods of the device and the standard method was within 10 mm Hg for more than 90% of both systolic and diastolic readings. During bicycle exercise, the mean differences in BP of standard method from K-method were ࢤ3 . 4 ± 4.8 mm Hg systole and 1.8 ± 5.2 mm Hg diastole (n = 71) and those of standard method from O-method were −1.1 ± 7.3 mm Hg systole and 1.7 ± 7.8 mm Hg diastole (n = 67). There was a greater scatter in the individual comparisons of the device and the standard method during exercise, especially in diastolic BP. The relation between the device and ORM was almost similar to that between the device and the standard method. In 130 subjects the mean ambulatory monitoring period with the TM 2421 was 23.7 ± 0.6 h. In the K-method the error codes (failed recordings) were given as 13.0% of measurements, while in the O-method it was 4.3%. When the data obtained by the K-method were added to the failures in the O-method, only 1% of expected recordings had failed. The results suggest that the A&D TM 2421 unit is valid for clinical and research study. Am J Hypertens 1992;5:719-726
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Blood pressure measuring devices: recommendations of the European Society of Hypertension
O'Brien, E., Waeber, B., Parati, G., Staessen, J., & Myers, M. G. (2001) · BMJ · doi:10.1136/bmj.322.7285.531 · Cited by 903
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Self-citationHansen, T. W., Kikuya, M., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Jeppesen, J., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281c49da5 · Cited by 383
Self-citationPrognostic Value of the Morning Blood Pressure Surge in 5645 Subjects From 8 Populations
Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Boggia, J., Richart, T., Metoki, H., Ohkubo, T., Torp-Pedersen, C., Kuznetsova, T., et al. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.137273 · Cited by 275
Self-citation
Metadata
- Authors
- Imai, Y., Sasaki, S., Minami, N., Munakata, M., Hashimoto, J., Sakuma, H., Sakuma, M., Watanabe, N., Imai, K., Sekino, H., & Abe, K.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-10
- Volume
- 5
- Issue
- 10
- Pages
- 719-726
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2340316228
- Cited by
- 130
- References
- 0
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Accuracy and Performance of the A&D TM 2421, a New Ambulatory Blood Pressure Monitoring Device Based on the Cuff-Oscillometric Method and the Korotkoff Sound Technique. https://app.cochat.ai/papers/10.1093/ajh/5.10.719
- The paper
- Imai, Y., Sasaki, S., Minami, N., Munakata, M., Hashimoto, J., Sakuma, H., Sakuma, M., Watanabe, N., Imai, K., Sekino, H., & Abe, K. (1992). The Accuracy and Performance of the A&D TM 2421, a New Ambulatory Blood Pressure Monitoring Device Based on the Cuff-Oscillometric Method and the Korotkoff Sound Technique. American Journal of Hypertension. https://doi.org/10.1093/ajh/5.10.719
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.