Effect of an automated bedside dispensing machine on medication errors
The DOI matches its Crossref record.
Abstract
The effect of an automated bedside dispensing machine on medication errors was studied on a 32-bed surgical unit of an 848-bed hospital. The experimental system (McLaughlin Dispensing System) included at each patient's bedside a locked medication cabinet that was electronically programmed to allow the nurse access to doses due at a particular time. The control system was a decentralized unit dose system. A crossover study design with random assignment of subjects and treatments was used. In the 14-day study period, nurses were observed by a pharmacist for 28 five-hour periods as they administered medications on the day and evening shifts. The mean error rates were significantly different--10.6% for the experimental system and 15.9% for the control system. Wrong time errors were the most common type. No significant differences were found between day and evening shifts or workloads of individual nurses. There was no treatment order effect. The error rate was significantly lower for the automated dispensing system than for the system using unit doses dispensed from a satellite pharmacy. Automated dispensing systems may be useful in reducing errors in administration time and dose omissions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Using information technology to reduce rates of medication errors in hospitals
Bates, D. W. (2000) · BMJ · doi:10.1136/bmj.320.7237.788 · Cited by 483
ASHP Guidelines on Preventing Medication Errors in Hospitals
Billstein-Leber, M., Carrillo, C. J. D., Cassano, A. T., Moline, K., & Robertson, J. J. (2018) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp170811 · Cited by 398
Bond, C. A., Raehl, C. L., & Franke, T. (2002) · Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.22.3.134.33551 · Cited by 236
“Central clinical pharmacy services Drug-use evaluation 1028 (95) 853 (95) In-service education 742 (69) 613 (68) Drug information 289 (27) 233 (26) Poison information 182 (17) 155 (17) Clinical research 168 (16) 134 (15)”
Impact of emerging technologies on medication errors and adverse drug events
Oren, E., Shaffer, E. R., & Guglielmo, B. J. (2003) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/60.14.1447 · Cited by 190
How are medication errors defined? A systematic literature review of definitions and characteristics
Lisby, M., Nielsen, L. P., Brock, B., & Mainz, J. (2010) · International Journal for Quality in Health Care · doi:10.1093/intqhc/mzq059 · Cited by 170
“Deviation Barker [30] USA (1984) A dose of medication that deviates from the physician’s medication order on the patient’s chart and an error was viewed as an instance of failure of the medication system RCT Ib Dose dispensing Surgical 1775 OE D, A Observation ME: 282/ 1775 (16)”
BackgroundReducing medication errors for adults in hospital settings
Ciapponi, A., Fernandez Nievas, S. E., Seijo, M., Rodríguez, M. B., Vietto, V., García-Perdomo, H. A., Virgilio, S., Fajreldines, A. V., Tost, J., Rose, C. J., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009985.pub2 · Cited by 105
Balka, E., Kahnamoui, N., & Nutland, K. (2007) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2006.05.038 · Cited by 46
Novek, J. (2002) · Science, Technology, & Human Values · doi:10.1177/016224390202700303 · Cited by 33
Jumeau, M., Francois, O., & Bonnabry, P. (2023) · European Journal of Hospital Pharmacy · doi:10.1136/ejhpharm-2021-002849 · Cited by 13
Metadata
- Authors
- Barker, K. N., Pearson, R. E., Hepler, C. D., Smith, W. E., & Pappas, C. A.
- Venue
- American Journal of Health-System Pharmacy
- Publisher
- Oxford University Press (OUP)
- Published
- 1984-07-01
- Volume
- 41
- Issue
- 7
- Pages
- 1352-1358
- ISSN
- 1079-2082 (ISSN-L)
- 1535-2900
- OpenAlex
- W2346265079
- Cited by
- 81
- References
- 0
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.