FUNGAL AND ACTINOMYCETE SPORES AS POLLUTANTS OF THE WORKPLACE AND OCCUPATIONAL ALLERGENS *
The DOI matches its Crossref record.
Abstract
Spores of fungi and actinomycetes are almost always present in air but their numbers and types differ with time of day, weather, season and location (especially if this is dominated by large nearby spore sources). Without a source of spores in a building, numbers indoors are usually smaller than outdoors but the types found are similar. Heaviest exposure to airborne spores is often found in the workplace. Important sources are agricultural crops, especially during harvesting or during handling and processing after storage. mushrooms, wood for timber or pulping, composts, food processing and, increasingly, biotechnological processes. Many of the spores concerned are 1–5 μm in diameter and they may number up to 10 10 spores m −3 air. Many of the organisms found are well-known allergens and have been implicated in occupational asthma or extrinsic allergic alveolitis. Some may also cause infection, e.g. Aspergillus fumigatus , or carry mycotoxins, e.g. Aspergillus flavus , while very intense exposure may cause ‘organic dust toxic syndrome’. Important factors in the development of occupational asthma and allergic alveolitis are predisposition and the nature, intensity and duration of exposure. Examples of exposure to fungal and actinomycete spores in different occupational environments are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Post-harvest control strategies: Minimizing mycotoxins in the food chain
Magan, N., & Aldred, D. (2007) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2007.07.034 · Cited by 676
Bioaerosols and occupational lung disease
Lacey, J., & Dutkiewicz, J. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90215-1 · Cited by 342
Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland
Pastuszka, J. S., Kyaw Tha Paw, U., Lis, D. O., Wlazło, A., & Ulfig, K. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00527-0 · Cited by 318
Eduard, W. (2009) · Critical Reviews in Toxicology · doi:10.3109/10408440903307333 · Cited by 251
“…Fungi can also be produced as an end-product, e�g�, baker’s yeast and mushrooms� Exposure levels often exceed 106 spores/m3 and can be as high as 1010 spores/m3 (reviews by Lacey & Crook, 1988; Malmberg, 1991)� High levels may occur when fungi colonise organic materials unintentionally� These…”
InfluentialFungi as contaminants in indoor air
Miller, J. D. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90404-9 · Cited by 236
Indoor fungi: companions and contaminants
Nevalainen, A., Täubel, M., & Hyvärinen, A. (2015) · Indoor Air · doi:10.1111/ina.12182 · Cited by 232
“…allergic alveolitis or hypersensitivity pneumonitis (farmer’s lung), occupational asthma, and organic dust toxic syndrome (ODTS), all of which are occupational diseases that are associated with agricultural work (doPico, 1986; Kotimaa et al., 1984; Lacey and Crook, 1988; Malmberg et al., 1993).”
BackgroundAccuracy, Precision, and Method Detection Limits of Quantitative PCR for Airborne Bacteria and Fungi
Hospodsky, D., Yamamoto, N., & Peccia, J. (2010) · Applied and Environmental Microbiology · doi:10.1128/aem.01240-10 · Cited by 205
“ubiquity in the environment and their allergenic and infectious potential (30, 31).”
BackgroundComparison of bioaerosol sampling methods in barns housing swine
Thorne, P. S., Kiekhaefer, M. S., Whitten, P., & Donham, K. J. (1992) · Applied and Environmental Microbiology · doi:10.1128/aem.58.8.2543-2551.1992 · Cited by 188
“eases associated with inhalation of agricultural dusts (23, 36).”
BackgroundAirborne microbiological characteristics in public buildings of Korea
Kim, K. Y., & Kim, C. N. (2007) · Building and Environment · doi:10.1016/j.buildenv.2006.04.013 · Cited by 174
Spore Carbon from Aspergillus Oryzae for Advanced Electrochemical Energy Storage
Zhong, Y., Xia, X., Deng, S., Xie, D., Shen, S., Zhang, K., Guo, W., Wang, X., & Tu, J. (2018) · Advanced Materials · doi:10.1002/adma.201805165 · Cited by 159
Bünger, J., Antlauf-Lammers, M., Schulz, T. G., Westphal, G. A., Müller, M. M., Ruhnau, P., & Hallier, E. (2000) · Occupational and Environmental Medicine · doi:10.1136/oem.57.7.458 · Cited by 158
Bioaerosols from composting facilities—a review
Wéry, N. (2014) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2014.00042 · Cited by 129
Suspended particulates and bioaerosols emitted from an agricultural non-point source
Abdel Hameed, A. A., & Khodr, M. I. (2001) · Journal of Environmental Monitoring · doi:10.1039/b007159p · Cited by 49
Microbial hazards during harvesting and processing at an outdoor United States cannabis farm
Green, B. J., Couch, J. R., Lemons, A. R., Burton, N. C., Victory, K. R., Nayak, A. P., & Beezhold, D. H. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1432863 · Cited by 43
Metadata
- Venue
- The Annals of Occupational Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-11-01
- Volume
- 32
- Issue
- 4
- Pages
- 515-33
- ISSN
- 0003-4878 (ISSN-L)
- 1475-3162
- OpenAlex
- W2100687858
- Cited by
- 248
- References
- 0
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.