A Survey of Wind Speeds in Indoor Workplaces
Open accessThe DOI matches its Crossref record.
Abstract
The applicability of the inhalable convention for sampling aerosols relies on its being a valid model for typical sampling environments. The current convention is based on measurements carried out in external wind speeds between 1 and 4 m. s−1. However these measurements show a degree of wind speed dependence, and it is uncertain at present how valid the convention is for describing human aspiration efficiency outside these wind speed limits. Following concerns that wind speeds in many indoor workplaces may be significantly below this range, measurements have been made in 55 work areas covering a wide range of workplaces. Measurements have concentrated on ‘background’ wind speeds where the influence of specific air movement sources is minimised. The pooled wind speed measurements show a highly skewed distribution with an arithmetic mean of approximately 0.3 m.s−1. Approximately 85% of all individual measurements were below this mean value. No obvious correlation was found between wind speed distribution parameters and industry type, room size or ventilation type. A limited number of comparisons were made between static anemometers and devices mounted on workers. It was found that modal wind speeds experience by workers were typically 0.05 m.s−1 higher than those measured using a static anemometer. These measurements agreed well with previously published data for similar workplaces as well as houses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wearable thermoelectrics for personalized thermoregulation
Hong, S., Gu, Y., Seo, J. K., Wang, J., Liu, P., Meng, Y. S., Xu, S., & Chen, R. (2019) · Science Advances · doi:10.1126/sciadv.aaw0536 · Cited by 522
Human convective boundary layer and its interaction with room ventilation flow
Licina, D., Melikov, A., Sekhar, C., & Tham, K. W. (2015) · Indoor Air · doi:10.1111/ina.12120 · Cited by 104
Overheating and passive habitability: indoor health and heat indices
Holmes, S. H., Phillips, T., & Wilson, A. (2016) · Building Research & Information · doi:10.1080/09613218.2015.1033875 · Cited by 91
“Wind speeds in mechanically ventilated workplaces are typically below 0.3 m/s (Baldwin & Maynard, 1998), whereas naturally ventilated buildings typically show air speeds above 0.2 m/s (Zhang, Arens, & Pasut, 2011).”
BackgroundInfluentialIndoor Aerosol Science Aspects of SARS-CoV-2 Transmission
Nazaroff, W. W. (2022) · Indoor Air · doi:10.1111/ina.12970 · Cited by 70
Licina, D., Melikov, A., Pantelic, J., Sekhar, C., & Tham, K. W. (2015) · Indoor Air · doi:10.1111/ina.12177 · Cited by 69
Metadata
- Venue
- The Annals of Occupational Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-07
- ISSN
- 0003-4878 (ISSN-L)
- 1475-3162
- OpenAlex
- W4240352723
- Cited by
- 98
- References
- 0
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Survey of Wind Speeds in Indoor Workplaces. https://app.cochat.ai/papers/10.1093/annhyg/42.5.303
- The paper
- A Survey of Wind Speeds in Indoor Workplaces. (1998). The Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/42.5.303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.