Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Wearable thermoelectrics for personalized thermoregulation

Open access

Abstract

Wearable thermoelectrics offers personalized thermoregulation with higher energy efficiency and enhanced thermal comfort.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.aaw0536

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 TED design and fabrication process. (A) Schematic illustration of cooling garments with wearable TEDs (left). The internal structure of the wearable TED with TE pillars connected by flexible copper electrodes and sandwiched between two stretchable sheets (right). (B) Photograph of the fabricated 5 cm by 5 cm flexible TED. (C) Schematic illustration of TED design. The low thermal conduction inside the TED and high thermal conduction within the stretchable sheets are the key features of the design used to achieve the cooling effect. (D) Schematic diagram and photographs showing the flexibility of the TED. The double-layer design of stretchable sheets enhances the flexibility. During bending, the top stretchable sheet expands, while the bottom stretchable sheet contracts. (E) Finite element simulation comparison of GTED and the bending stiffness of double- and single-layer designs of flexible TEDs as a function of TE pillar height. The double-layer design reduces GTED by 50% and the bending stiffness by 70% compared to those of the single-layer design. (F) Fabrication process of the TED (see Materials and Methods for details). Photo credit: Sahngki Hong, University of California, San Diego.
Fig. 1 TED design and fabrication process. (A) Schematic illustration of cooling garments with wearable TEDs (left). The internal structure of the wearable TED with TE pillars connected by flexible copper electrodes and sandwiched between two stretchable sheets (right). (B) Photograph of the fabricated 5 cm by 5 cm flexible TED. (C) Schematic illustration of TED design. The low thermal conduction inside the TED and high thermal conduction within the stretchable sheets are the key features of the design used to achieve the cooling effect. (D) Schematic diagram and photographs showing the flexibility of the TED. The double-layer design of stretchable sheets enhances the flexibility. During bending, the top stretchable sheet expands, while the bottom stretchable sheet contracts. (E) Finite element simulation comparison of GTED and the bending stiffness of double- and single-layer designs of flexible TEDs as a function of TE pillar height. The double-layer design reduces GTED by 50% and the bending stiffness by 70% compared to those of the single-layer design. (F) Fabrication process of the TED (see Materials and Methods for details). Photo credit: Sahngki Hong, University of California, San Diego.CC BY-NC · PubMed Central
Fig. 2 Characterization of the TED. (A) Measurement of the thermal conductance of the TED (GTED). A GTED value of 32 W m−2 K−1 was determined from the slope of the temperature differences between the cold and hot sides (ΔT) versus the applied heat flux to the underlying heater, when there is no current applied to the TED (i.e., passive mode). (B) Measurement of the device-level Seebeck coefficient (S = 196 μV K−1) by comparing ΔT and corresponding open-circuit voltages (VOC). (C) Thermal conductivity of the polymeric Ecoflex stretchable sheets (kp) for various volume ratios of the Ecoflex and AlN microparticles. The mixture layer containing 26 volume % of AlN microparticles exhibited kp = 0.77 W m−1 K−1, which is four times higher than that of pristine Ecoflex (kp = 0.20 W m−1 K−1). (D) Finite element simulation of cooling/heating effect with the measured TED parameters. More than 7°C maximum cooling was estimated with only natural convection and radiation. (E) Electrical resistance (R) stability for various bending radii (r) from flat to 20 mm, where R0 is R when the TED is flat, and ΔR is the difference between R and R0. (F) Electrical resistance stability over 1000 bending cycles with r = 30 mm. Photo credit: Sahngki Hong, University of California, San Diego.
Fig. 2 Characterization of the TED. (A) Measurement of the thermal conductance of the TED (GTED). A GTED value of 32 W m−2 K−1 was determined from the slope of the temperature differences between the cold and hot sides (ΔT) versus the applied heat flux to the underlying heater, when there is no current applied to the TED (i.e., passive mode). (B) Measurement of the device-level Seebeck coefficient (S = 196 μV K−1) by comparing ΔT and corresponding open-circuit voltages (VOC). (C) Thermal conductivity of the polymeric Ecoflex stretchable sheets (kp) for various volume ratios of the Ecoflex and AlN microparticles. The mixture layer containing 26 volume % of AlN microparticles exhibited kp = 0.77 W m−1 K−1, which is four times higher than that of pristine Ecoflex (kp = 0.20 W m−1 K−1). (D) Finite element simulation of cooling/heating effect with the measured TED parameters. More than 7°C maximum cooling was estimated with only natural convection and radiation. (E) Electrical resistance (R) stability for various bending radii (r) from flat to 20 mm, where R0 is R when the TED is flat, and ΔR is the difference between R and R0. (F) Electrical resistance stability over 1000 bending cycles with r = 30 mm. Photo credit: Sahngki Hong, University of California, San Diego.CC BY-NC · PubMed Central
Fig. 3 Power generation of the TED and its impact on active cooling. (A) Schematic diagram of the measurement setup used to monitor power generation on human skin. The voltage and current were measured with various load resistors while the TED was attached to the wearer’s arm. (B) Power generation as a function of output voltage under various thermal conditions. (C) Summary of the maximum power generation from our TED on a heater or human skin. The maximum power generation on human skin was 4.5 μW cm−2, and the open-circuit voltage (VOC) was 74.5 mV at room temperature (Tair = 22°C) with natural convection (sitting). The power generation increased up to 10.7 μW cm−2 with mild forced convection (walking) and up to 25.1 μW cm−2 under cold conditions (sitting, Tair = 10°C). (D) Summary of power generation and VOC of wearable TEDs from the literature. All the measurements were performed on human skin without heat sinks at room temperature. (E) Simulation results comparing cooling (Peltier effect, black) and power generation (Seebeck effect, blue) performance as functions of GTED and ZT (right) and schematic illustration of the geometry and thermal conditions used in the simulation (left).
Fig. 3 Power generation of the TED and its impact on active cooling. (A) Schematic diagram of the measurement setup used to monitor power generation on human skin. The voltage and current were measured with various load resistors while the TED was attached to the wearer’s arm. (B) Power generation as a function of output voltage under various thermal conditions. (C) Summary of the maximum power generation from our TED on a heater or human skin. The maximum power generation on human skin was 4.5 μW cm−2, and the open-circuit voltage (VOC) was 74.5 mV at room temperature (Tair = 22°C) with natural convection (sitting). The power generation increased up to 10.7 μW cm−2 with mild forced convection (walking) and up to 25.1 μW cm−2 under cold conditions (sitting, Tair = 10°C). (D) Summary of power generation and VOC of wearable TEDs from the literature. All the measurements were performed on human skin without heat sinks at room temperature. (E) Simulation results comparing cooling (Peltier effect, black) and power generation (Seebeck effect, blue) performance as functions of GTED and ZT (right) and schematic illustration of the geometry and thermal conditions used in the simulation (left).CC BY-NC · PubMed Central
Fig. 4 Cooling and heating performance. (A) Laboratory cooling/heating measurement setup. The heating power of a heater (Qskin) was fixed at 87 W m−2 (measured by a heat flux sensor) to simulate the typical metabolic rate from a human. (B) Time-dependent cooling/heating effects from the TED. (C) Sustainable cooling effect for a long period (8 hours) with an electrical current of 140 mA. (D) Summary of temperature changes (black) and coefficient of performance (COP) (blue) during TED operation with natural convection. The maximum temperature decrease was 7.3°C. (E) Summary of temperature changes (black) and COP (blue) during TED operation with mild forced convection (5 km hour−1 wind). The maximum temperature decrease was more than 13.6°C. (F) Cooling/heating effects for bending radii (r) of 30 and 40 mm, showing no change compared with those on the flat setup. The inset shows the measurement setup to test the cooling/heating effect of the TED under bending. (G) Schematic of a human skin setup to demonstrate TED thermoregulation. (H) Thermoregulation measurement results. The surface temperature of the polydimethylsiloxane layer (Tskin) was maintained by TED cooling and heating within the entire range of ambient temperature. Photo credit: Sahngki Hong, University of California, San Diego.
Fig. 4 Cooling and heating performance. (A) Laboratory cooling/heating measurement setup. The heating power of a heater (Qskin) was fixed at 87 W m−2 (measured by a heat flux sensor) to simulate the typical metabolic rate from a human. (B) Time-dependent cooling/heating effects from the TED. (C) Sustainable cooling effect for a long period (8 hours) with an electrical current of 140 mA. (D) Summary of temperature changes (black) and coefficient of performance (COP) (blue) during TED operation with natural convection. The maximum temperature decrease was 7.3°C. (E) Summary of temperature changes (black) and COP (blue) during TED operation with mild forced convection (5 km hour−1 wind). The maximum temperature decrease was more than 13.6°C. (F) Cooling/heating effects for bending radii (r) of 30 and 40 mm, showing no change compared with those on the flat setup. The inset shows the measurement setup to test the cooling/heating effect of the TED under bending. (G) Schematic of a human skin setup to demonstrate TED thermoregulation. (H) Thermoregulation measurement results. The surface temperature of the polydimethylsiloxane layer (Tskin) was maintained by TED cooling and heating within the entire range of ambient temperature. Photo credit: Sahngki Hong, University of California, San Diego.CC BY-NC · PubMed Central
Fig. 5 Demonstration of thermoregulation on human skin. (A) Photograph and schematic diagram of the TED armband. The wearer’s arm was encompassed by a controlled thermal environment. (B) Change in Tskin under various Tair conditions before and after TED operation. Without TED operation, Tskin varied from 28.5° to 34.3°C, while Tair changed from 22° to 36°C. With active thermoregulation of the TED, Tskin converged to the preset comfort temperature (32°C) under all the Tair conditions. (C) IR image of the TED armband (hot side) during cooling (I = 160 mA) on the subject’s arm. (D) IR image of the skin after removing the TED armband, showing residual cooling effect. (E) Summary of Tskin as a function of Tair with and without TED operation. The cooling and heating of the TED broadened the comfortable ambient temperature zone from 2°C (Tair = 28° to 30°C) to 14°C (Tair = 22° to 36°C). (F) Schematic of the TED armband integrated with the flexible battery pack (photograph). (G) Skin temperature change by TED cooling under three conditions: (1) sitting indoors, (2) walking indoors, and (3) walking outdoors under mild wind conditions. The maximum skin cooling effect was 6°C. Photo credit: Sahngki Hong, University of California, San Diego.
Fig. 5 Demonstration of thermoregulation on human skin. (A) Photograph and schematic diagram of the TED armband. The wearer’s arm was encompassed by a controlled thermal environment. (B) Change in Tskin under various Tair conditions before and after TED operation. Without TED operation, Tskin varied from 28.5° to 34.3°C, while Tair changed from 22° to 36°C. With active thermoregulation of the TED, Tskin converged to the preset comfort temperature (32°C) under all the Tair conditions. (C) IR image of the TED armband (hot side) during cooling (I = 160 mA) on the subject’s arm. (D) IR image of the skin after removing the TED armband, showing residual cooling effect. (E) Summary of Tskin as a function of Tair with and without TED operation. The cooling and heating of the TED broadened the comfortable ambient temperature zone from 2°C (Tair = 28° to 30°C) to 14°C (Tair = 22° to 36°C). (F) Schematic of the TED armband integrated with the flexible battery pack (photograph). (G) Skin temperature change by TED cooling under three conditions: (1) sitting indoors, (2) walking indoors, and (3) walking outdoors under mild wind conditions. The maximum skin cooling effect was 6°C. Photo credit: Sahngki Hong, University of California, San Diego.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 522

Metadata

Authors
Hong, S., Gu, Y., Seo, J. K., Wang, J., Liu, P., Meng, Y. S., Xu, S., & Chen, R.
Affiliations
University of California San Diego (US)
Corresponding author
  • Xu, Sheng
  • Chen, Renkun
Venue
Science Advances
Published
2019-05-03
Volume
5
Issue
5
Pages
eaaw0536-eaaw0536
ISSN
2375-2548 (ISSN-L)
OpenAlex
W2946206200
Cited by
522
References
40
Citations by year
2026: 51 · 2025: 77 · 2024: 105 · 2023: 79 · 2022: 76 · 2021: 76 · 2020: 46 · 2019: 12
FWCI
18.96
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
Funders
Advanced Research Projects Agency - Energy (DE-AR0000535)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Advanced Thermoelectric Materials and Devices
  • Physical Sciences › Engineering › Civil and Structural Engineering › Thermal Radiation and Cooling Technologies
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
Keywords
active cooling, flexible thermoelectric devices, coefficient of performance, human comfort, energy consumption reduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wearable thermoelectrics for personalized thermoregulation. https://app.cochat.ai/papers/10.1126/sciadv.aaw0536
The paper
Hong, S., Gu, Y., Seo, J. K., Wang, J., Liu, P., Meng, Y. S., Xu, S., & Chen, R. (2019). Wearable thermoelectrics for personalized thermoregulation. Science Advances. https://doi.org/10.1126/sciadv.aaw0536

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.