CoChat

Comparison of Nanoparticle Filtration Performance of NIOSH-approved and CE-Marked Particulate Filtering Facepiece Respirators

Rengasamy, S., Eimer, B. C., Shaffer, R. E. · 2009 · Annals of Occupational Hygiene
Cited by 156

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The National Institute for Occupational Safety and Health (NIOSH) and European Norms (ENs) employ different test protocols for evaluation of air-purifying particulate respirators commonly referred to as filtering facepiece respirators (FFR). The relative performance of the NIOSH-approved and EN-certified 'Conformité Européen' (CE)-marked FFR is not well studied. NIOSH requires a minimum of 95 and 99.97% efficiencies for N95 and P100 FFR, respectively; meanwhile, the EN requires 94 and 99% efficiencies for FFRs, class P2 (FFP2) and class P3 (FFP3), respectively. To better understand the filtration performance of NIOSH- and CE-marked FFRs, initial penetration levels of N95, P100, FFP2 and FFP3 respirators were measured using a series of polydisperse and monodisperse aerosol test methods and compared. Initial penetration levels of polydisperse NaCl aerosols [mass median diameter (MMD) of 238 nm] were measured using a method similar to the NIOSH respirator certification test method. Monodisperse aerosol penetrations were measured using silver particles for 4-30 nm and NaCl particles for 20-400 nm ranges. Two models for each FFR type were selected and five samples from each model were tested against charge neutralized aerosol particles at 85 l min(-1) flow rate. Penetrations from the 238 nm MMD polydisperse aerosol test were <1% for N95 and FFP2 models and <0.03% for P100 and FFP3 models. Monodisperse aerosol penetration levels showed that the most penetrating particle size (MPPS) was in the 30-60 nm range for all models of FFRs tested in the study. Percentage penetrations at the MPPS were <4.28, <2.22, <0.009 and <0.164 for the N95, FFP2, P100 and FFP3 respirator models, respectively. The MPPS obtained for all four FFR types suggested particle capturing by electrostatic mechanism. Liquid isopropanol treatment of FFRs shifted the MPPS to 200-300 nm and dramatically increased polydisperse as well as monodisperse aerosol penetrations of all four FFR types indicating that all the four FFR types share filtration characteristics of electret filters. Electrostatic charge removal from all four FFR types also increased penetration levels of 400-1000 nm range particles. Particle penetration data obtained in this study showed that the eight models of NIOSH-approved N95 and P100 and CE-marked FFP2 and FFP3 respirators used in this study provided expected levels of laboratory filtration performance against nanoparticles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/annhyg/men086

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 156

Metadata

Authors
Rengasamy, S., Eimer, B. C., & Shaffer, R. E.
Venue
Annals of Occupational Hygiene
Published
2009-03-01
Volume
53
Issue
2
Pages
117-128
ISSN
  • 0003-4878 (ISSN-L)
  • 1475-3162
OpenAlex
W2110745369
Cited by
156
References
3
FWCI
8.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Nanoparticle Filtration Performance of NIOSH-approved and CE-Marked Particulate Filtering Facepiece Respirators. https://app.cochat.ai/papers/10.1093/annhyg/men086
The paper
Rengasamy, S., Eimer, B. C., & Shaffer, R. E. (2009). Comparison of Nanoparticle Filtration Performance of NIOSH-approved and CE-Marked Particulate Filtering Facepiece Respirators. Annals of Occupational Hygiene. https://doi.org/10.1093/annhyg/men086

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.