The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Improved peak detection in mass spectrum by incorporating continuous wavelet transform-based pattern matching
Open accessAbstract
Motivation: A major problem for current peak detection algorithms is that noise in mass spectrometry (MS) spectra gives rise to a high rate of false positives. The false positive rate is especially problematic in detecting peaks with low amplitudes. Usually, various baseline correction algorithms and smoothing methods are applied before attempting peak detection. This approach is very sensitive to the amount of smoothing and aggressiveness of the baseline correction, which contribute to making peak detection results inconsistent between runs, instrumentation and analysis methods. Results: Most peak detection algorithms simply identify peaks based on amplitude, ignoring the additional information present in the shape of the peaks in a spectrum. In our experience, ‘true’ peaks have characteristic shapes, and providing a shape-matching function that provides a ‘goodness of fit’ coefficient should provide a more robust peak identification method. Based on these observations, a continuous wavelet transform (CWT)-based peak detection algorithm has been devised that identifies peaks with different scales and amplitudes. By transforming the spectrum into wavelet space, the pattern-matching problem is simplified and in addition provides a powerful technique for identifying and separating the signal from the spike noise and colored noise. This transformation, with the additional information provided by the 2D CWT coefficients can greatly enhance the effective signal-to-noise ratio. Furthermore, with this technique no baseline removal or peak smoothing preprocessing steps are required before peak detection, and this improves the robustness of peak detection under a variety of conditions. The algorithm was evaluated with SELDI-TOF spectra with known polypeptide positions. Comparisons with two other popular algorithms were performed. The results show the CWT-based algorithm can identify both strong and weak peaks while keeping false positive rate low. Availability: The algorithm is implemented in R and will be included as an open source module in the Bioconductor project. Contact: s-lin2@northwestern.edu Supplementary material: . Colour versions of the figures in this article can be found at Bioinformatics Online.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631
Bioinformatics and Computational Biology Solutions Using R and Bioconductor
(2005) · Statistics for Biology and Health · doi:10.1007/0-387-29362-0 · Cited by 3,289
Coombes, K. R., Tsavachidis, S., Morris, J. S., Baggerly, K. A., Hung, M., & Kuerer, H. M. (2005) · PROTEOMICS · doi:10.1002/pmic.200401261 · Cited by 328
Independent Validation of Candidate Breast Cancer Serum Biomarkers Identified by Mass Spectrometry
Li, J., Orlandi, R., White, C. N., Rosenzweig, J., Zhao, J., Seregni, E., Morelli, D., Yu, Y., Meng, X.-Y., Zhang, Z., et al. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.052878 · Cited by 183
Processing and classification of protein mass spectra
Hilario, M., Kalousis, A., Pellegrini, C., & Müller, M. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20072 · Cited by 172
Andreev, V. P., Rejtar, T., Chen, H.-S., Moskovets, E. V., Ivanov, A. R., & Karger, B. L. (2003) · Analytical Chemistry · doi:10.1021/ac0301806 · Cited by 145
Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals
Vivó‐Truyols, G., Torres-Lapasió, J. R., van Nederkassel, A. M., Heyden, Y. V., & Massart, D. L. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.03.092 · Cited by 144
Gras, R., Müller, M., Gasteiger, E., Gay, S., Binz, P., Bienvenut, W. V., Hoogland, C., Sanchez, J., Bairoch, A., Hochstrasser, D. F., et al. (1999) · Electrophoresis · Cited by 136
Practical Time-Frequency Analysis - Gabor and Wavelet Transforms with an Implementation in S
(1998) · Wavelet analysis and its applications · doi:10.1016/s1874-608x(98)x8024-6 · Cited by 121
Algorithms for alignment of mass spectrometry proteomic data
Jeffries, N. O. (2005) · Computer applications in the biosciences · doi:10.1093/bioinformatics/bti482 · Cited by 95
HIGH-ACCURACY PEAK PICKING OF PROTEOMICS DATA USING WAVELET TECHNIQUES
Lange, E., Gröpl, C., Reinert, K., Kohlbacher, O., & Hildebrandt, A. (2005) · Pacific Symposium on Biocomputing (PSB) · doi:10.1142/9789812701626_0023 · Cited by 91
Preprocessing of tandem mass spectrometric data to support automatic protein identification
Gentzel, M., Köcher, T., Ponnusamy, S., & Wilm, M. S. (2003) · PROTEOMICS · doi:10.1002/pmic.200300486 · Cited by 83
Wavelet change-point prediction of transmembrane proteins
Lió, P., & Vannucci, M. (2000) · Bioinformatics · doi:10.1093/bioinformatics/16.4.376 · Cited by 81
Qu, Y., Adam, B.-L., Thornquist, M. D., Potter, J. D., Thompson, M. L., Yasui, Y., Davis, J. W., Schellhammer, P. F., Cazares, L. H., Clements, M., et al. (2003) · Biometrics · doi:10.1111/1541-0420.00017 · Cited by 80
Klevecz, R. R., & Murray, D. B. (2001) · Molecular Biology Reports · doi:10.1023/a:1017909012215 · Cited by 54
Cited by
Highly sensitive feature detection for high resolution LC/MS
Tautenhahn, R., Böttcher, C., & Neumann, S. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-504 · Cited by 1,185
Analytical Methods in Untargeted Metabolomics: State of the Art in 2015
Alonso, A., Marsal, S., & JuliÃ, A. (2015) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2015.00023 · Cited by 681
An Efficient Algorithm for Automatic Peak Detection in Noisy Periodic and Quasi-Periodic Signals
Scholkmann, F., Boss, J., & Wolf, M. (2012) · Algorithms · doi:10.3390/a5040588 · Cited by 453
Myers, O. D., Sumner, S. J., Li, S., Barnes, S., & Du, X. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00947 · Cited by 433
Pre-processing of hyperspectral images. Essential steps before image analysis
Vidal, M., & Amigo, J. M. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.05.009 · Cited by 367
Metadata
- Authors
- Du, P., Kibbe, W. A., & Lin, S. M.
- Venue
- Bioinformatics
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-07-04
- Volume
- 22
- Issue
- 17
- Pages
- 2059-2065
- ISSN
- 1367-4803 (ISSN-L)
- 1367-4811
- OpenAlex
- W2168130065
- Cited by
- 763
- References
- 16
- FWCI
- 8.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.