Identifiability of isoform deconvolution from junction arrays and RNA-Seq
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Motivation: Splice junction microarrays and RNA-seq are two popular ways of quantifying splice variants within a cell. Unfortunately, isoform expressions cannot always be determined from the expressions of individual exons and splice junctions. While this issue has been noted before, the extent of the problem on various platforms has not yet been explored, nor have potential remedies been presented. Results: We propose criteria that will guarantee identifiability of an isoform deconvolution model on exon and splice junction arrays and in RNA-Seq. We show that up to 97% of 2256 alternatively spliced human genes selected from the RefSeq database lead to identifiable gene models in RNA-seq, with similar results in mouse. However, in the Human Exon array only 26% of these genes lead to identifiable models, and even in the most comprehensive splice junction array only 69% lead to identifiable models. Contact: whwong@stanford.edu Supplementary information: Supplementary data are available at Bioinformatics online.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pan, Q., Shai, O., Lee, L. J., Frey, B. J., & Blencowe, B. J. (2008) · Nature Genetics · doi:10.1038/ng.259 · Cited by 3,951
Pan, Q., Shai, O., Misquitta, C., Zhang, W., Saltzman, A. L., Mohammad, N., Babak, T., Siu, H., Hughes, T. R., Morris, Q. D., et al. (2004) · Molecular Cell · doi:10.1016/j.molcel.2004.12.004 · Cited by 323
Cited by
Trapnell, C., Williams, B. A., Pertea, G., Mortazavi, A., Kwan, G., van Baren, M. J., Salzberg, S. L., Wold, B. J., & Pachter, L. (2010) · Nature Biotechnology · doi:10.1038/nbt.1621 · Cited by 15,556
Differential analysis of gene regulation at transcript resolution with RNA-seq
Trapnell, C., Hendrickson, D. G., Sauvageau, M., Goff, L., Rinn, J. L., & Pachter, L. (2013) · Nature Biotechnology · doi:10.1038/nbt.2450 · Cited by 3,492
“Count uncertainty refers to the observation that in RNA-seq experiments it is common for up to 50% of reads to map ambiguously to different transcripts 29 .”
BackgroundTranscriptome genetics using second generation sequencing in a Caucasian population
Montgomery, S. B., Sammeth, M., Gutierrez-Arcelus, M., Lach, R. P., Ingle, C., Nisbett, J., Guigo, R., & Dermitzakis, E. T. (2010) · Nature · doi:10.1038/nature08903 · Cited by 797
Uncovering the Complexity of Transcriptomes with RNA-Seq
Costa, V., Angelini, C., De Feis, I., & Ciccodicola, A. (2010) · Journal of Biomedicine and Biotechnology · doi:10.1155/2010/853916 · Cited by 439
Characterization of the human ESC transcriptome by hybrid sequencing
Au, K. F., Sebastiano, V., Afshar, P. T., Durruthy, J. D., Lee, L., Williams, B. A., van Bakel, H., Schadt, E. E., Reijo-Pera, R. A., Underwood, J. G., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1320101110 · Cited by 341
“In previous work we showed that generally, isoform deconvolution from short-read RNA-Seq data is not an identifiable problem (13), in the sense that isoform expression cannot always be uniquely determined from the set of exons and splice junctions.”
BackgroundSelf-citationSelf-Recognition of an Inducible Host lncRNA by RIG-I Feedback Restricts Innate Immune Response
Jiang, M., Zhang, S., Yang, Z., Lin, H., Zhu, J., Liu, L., Wang, W., Liu, S., Liu, W., Ma, Y., et al. (2018) · Cell · doi:10.1016/j.cell.2018.03.064 · Cited by 297
RNA-seq: technical variability and sampling
McIntyre, L. M., Lopiano, K. K., Morse, A. M., Amin, V., Oberg, A. L., Young, L. J., & Nuzhdin, S. V. (2011) · BMC Genomics · doi:10.1186/1471-2164-12-293 · Cited by 285
A comparison of statistical methods for detecting differentially expressed genes from RNA‐seq data
Kvam, V. M., Liu, P., & Si, Y. (2012) · American Journal of Botany · doi:10.3732/ajb.1100340 · Cited by 281
The study of eQTL variations by RNA-seq: from SNPs to phenotypes
Majewski, J., & Pastinen, T. (2011) · Trends in Genetics · doi:10.1016/j.tig.2010.10.006 · Cited by 232
Next-generation sequencing and its applications in molecular diagnostics
Su, Z., Ning, B., Fang, H., Hong, H., Perkins, R., Tong, W., & Shi, L. (2011) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.11.3 · Cited by 179
Estimation of alternative splicing isoform frequencies from RNA-Seq data
Nicolae, M., Mangul, S., Măndoiu, I. I., & Zelikovsky, A. (2011) · Algorithms for Molecular Biology · doi:10.1186/1748-7188-6-9 · Cited by 178
“However, despite sophisticated deconvolution algorithms [4,5], the fragmentary information provided by splicing arrays is typically insufficient for unambiguous identification of full-length transcripts [6,7].”
BackgroundStatistical Modeling of RNA-Seq Data
Salzman, J., Jiang, H., & Wong, W. H. (2011) · Statistical Science · doi:10.1214/10-sts343 · Cited by 68
Self-citation
Metadata
- Authors
- Hiller, D., Jiang, H., Xu, W., & Wong, W. H.
- Venue
- Bioinformatics
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-09-16
- Volume
- 25
- Issue
- 23
- Pages
- 3056-3059
- ISSN
- 1367-4803 (ISSN-L)
- 1367-4811
- OpenAlex
- W2113386140
- Cited by
- 65
- References
- 2
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.