The DOI matches its Crossref record; 34 of the 36 references it cites were found in a registry or an index.
High STOP-Bang score indicates a high probability of obstructive sleep apnoea
Open accessAbstract
BACKGROUND: The STOP-Bang questionnaire is used to screen patients for obstructive sleep apnoea (OSA). We evaluated the association between STOP-Bang scores and the probability of OSA. METHODS: After Institutional Review Board approval, patients who visited the preoperative clinics for a scheduled inpatient surgery were approached for informed consent. Patients answered STOP questionnaire and underwent either laboratory or portable polysomnography (PSG). PSG recordings were scored manually. The BMI, age, neck circumference, and gender (Bang) were documented. Over 4 yr, 6369 patients were approached and 1312 (20.6%) consented. Of them, 930 completed PSG, and 746 patients with complete data on PSG and STOP-Bang questionnaire were included for data analysis. RESULTS: The median age of 746 patients was 60 yr, 49% males, BMI 30 kg m(-2), and neck circumference 39 cm. OSA was present in 68.4% with 29.9% mild, 20.5% moderate, and 18.0% severe OSA. For a STOP-Bang score of 5, the odds ratio (OR) for moderate/severe and severe OSA was 4.8 and 10.4, respectively. For STOP-Bang 6, the OR for moderate/severe and severe OSA was 6.3 and 11.6, respectively. For STOP-Bang 7 and 8, the OR for moderate/severe and severe OSA was 6.9 and 14.9, respectively. The predicted probabilities for moderate/severe OSA increased from 0.36 to 0.60 as the STOP-Bang score increased from 3 to 7 and 8. CONCLUSIONS: In the surgical population, a STOP-Bang score of 5-8 identified patients with high probability of moderate/severe OSA. The STOP-Bang score can help the healthcare team to stratify patients for unrecognized OSA, practice perioperative precautions, or triage patients for diagnosis and treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The STOP-BANG questionnaire has a high sensitivity where a score of ≥3 score is associated with an increased risk of moderate-to-severe OSA,470,492,493 and a higher rate of perioperative complications.469,471,473,475–477,485,486,494–496”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [492]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · Cited by 6,530
McNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d83e4 · Cited by 2,355
Self-citationSleep Disordered Breathing and Mortality: Eighteen-Year Follow-up of the Wisconsin Sleep Cohort
(2008) · Sleep · doi:10.5665/sleep/31.8.1071 · Cited by 1,853
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
(2006) · Anesthesiology · doi:10.1097/00000542-200605000-00026 · Cited by 1,188
Sleep-Disordered Breathing in Community-Dwelling Elderly
Ancoli-Israel, S., Ancoli-Israel, S., Kripke, D. F., Kripke, D. F., Klauber, M. R., Mason, W. J., Mason, W. J., Fell, R., Fell, R., & Kaplan, O. (1991) · Sleep · doi:10.1093/sleep/14.6.486 · Cited by 934
Sleep Apnea as an Independent Risk Factor for All-Cause Mortality: The Busselton Health Study
(2008) · Sleep · doi:10.5665/sleep/31.8.1079 · Cited by 889
GUPTA, R. M., PARVIZI, J., HANSSEN, A. D., & GAY, P. C. (2001) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(11)62108-3 · Cited by 623
Cited by
Kapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253
Chung, F., Abdullah, H. R., & Liao, P. (2016) · Chest · doi:10.1378/chest.15-0903 · Cited by 1,362
“Bang ¼ BMI, age, neck circumference, and male gender; NPV ¼ negative predictive value; PPV ¼ positive predictive value; STOP ¼ snoring, tiredness, observed apnea, and high BP. (Adapted with permission Chung et al.43) 634 Commentary [ 1 4 9 # 3 CHES T MA R C H 2 0 1 6 ] OSA without meeting criteria of overt chronic day…”
BackgroundInfluentialSelf-citationYoung, T. (2002) · Archives of Internal Medicine · doi:10.1001/archinte.162.8.893 · Cited by 1,304
ATUALIZAÇÃO DA DIRETRIZ BRASILEIRA DE DISLIPIDEMIAS E PREVENÇÃO DA ATEROSCLEROSE - 2017
Faludi, A., Izar, M., Saraiva, J., Chacra, A., Bianco, H., Afiune Neto, A., Bertolami, A., Pereira, A., Lottenberg, A., Sposito, A., et al. (2017) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20170121 · Cited by 633
Nagappa, M., Liao, P., Wong, J., Auckley, D., Ramachandran, S. K., Memtsoudis, S., Mokhlesi, B., & Chung, F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0143697 · Cited by 684
Self-citation
Metadata
- Authors
- Chung, F., Subramanyam, R., Liao, P., Sasaki, E., Shapiro, C., & Sun, Y.
- Affiliations
- University Health Network (CA)
- Corresponding author
- Chung, F.
- Venue
- British Journal of Anaesthesia
- Publisher
- Elsevier BV
- Published
- 2012-05
- Volume
- 108
- Issue
- 5
- Pages
- 768-775
- ISSN
- 0007-0912 (ISSN-L)
- PMC
- PMC3325050
- OpenAlex
- W2130254450
- Cited by
- 988
- References
- 36
- Citations by year
- 2026: 31 · 2025: 82 · 2024: 67 · 2023: 50 · 2022: 58 · 2021: 93 · 2020: 77 · 2019: 65 · 2018: 82 · 2017: 120 · 2016: 72 · 2015: 69 · 2014: 63 · 2013: 40 · 2012: 16
- FWCI
- 40.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc/4.0/ (vor, 2043 d)
- Locations
- British Journal of Anaesthesia (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Funders
- ResMed
- University of Toronto
- University Health Network Foundation
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- obstructive sleep apnea, STOP-BANG questionnaire, OSA screening, polysomnography, preoperative screening, surgical patients, OSA severity, patient stratification
- MeSH terms
- Aged, Female, Humans, Male, Mass Screening, Middle Aged, Neck, Predictive Value of Tests, Prospective Studies, Severity of Illness Index, Body Mass Index, Polysomnography, Sleep Apnea, Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High STOP-Bang score indicates a high probability of obstructive sleep apnoea. https://app.cochat.ai/papers/10.1093/bja/aes022
- The paper
- Chung, F., Subramanyam, R., Liao, P., Sasaki, E., Shapiro, C., & Sun, Y. (2012). High STOP-Bang score indicates a high probability of obstructive sleep apnoea. British Journal of Anaesthesia. https://doi.org/10.1093/bja/aes022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.