Methodology of method comparison studies evaluating the validity of cardiac output monitors: a stepwise approach and checklist
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 9×
“Accuracy refers to the mean deviation between a new CO monitor and true CO.”
InfluentialMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435 · cited 1×
“In analogy with error grids used to validate new glucose measurement devices, this (dis)agreement can be further divided from the perspective of therapeutic consequences.(29) An error grid can be created to reflect the therapeutic consequences in specific zones in the concordance plot (Fig.”
MethodCritchley, L. A. H., & Critchley, J. A. J. H. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009982611386 · Cited by 1,325
I. Using the Bland–Altman method to measure agreement with repeated measures
Myles, P. S., & Cui, J. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem214 · Cited by 620
Critchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512 · cited 3×
“An increasing number of studies focus on the ability to track changes in CO, in addition to determining its absolute value.(9) 10 Evaluation of the trend in COmight be helpful to evaluate the effects of interventions and is intuitive, because CO is continuously changing as a result of a variety of influences, such as…”
BackgroundMethodInfluentialPeyton, P. J., & Chong, S. W. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ee3130 · Cited by 456
Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation.
Michard, F., & Teboul, J. (2000) · Critical Care · doi:10.1186/cc710 · Cited by 409 · cited 1×
“24 25 28 The absolute value of CO is useful to consider in the diagnostic work-up of critical care patients.”
Confidence in Altman–Bland plots: A critical review of the method of differences
Ludbrook, J. (2010) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2009.05288.x · Cited by 366 · cited 2×
“…with linear regression can be plotted against the mean CO. 14 If the bias or LOA are non-uniform, transformation of the data or regression analysis can be applied to prevent under-and overestimation in speci fi c measurement ranges; 14 17 however, this limits the interpretation of the study results.”
Cecconi, M., Rhodes, A., Poloniecki, J., Della Rocca, G., & Grounds, R. M. (2009) · Critical Care · doi:10.1186/cc7129 · Cited by 351
Errors in the measurement of cardiac output by thermodilution
Nishikawa, T., & Dohi, S. (1993) · Canadian Journal of Anaesthesia · doi:10.1007/bf03011312 · Cited by 302 · cited 1×
“10 Evaluation of the trend in COmight be helpful to evaluate the effects of interventions and is intuitive, because CO is continuously changing as a result of a variety of influences, such as respiration, the autonomic nervous system, and changes in metabolic demand.(24) 25 28 The absolute value of CO is useful to con…”
BackgroundComparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis
Mantha, S., Roizen, M. F., Fleisher, L. A., Thisted, R., & Foss, J. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200003000-00018 · Cited by 266 · cited 4×
“Despite these reviews, many studies do not meet a number of fundamental principles.(3) 8 This may lead to incorrect conclusions and erroneous applications in clinical practice.”
BackgroundMethodInfluentialAssessment of Trending Ability of Cardiac Output Monitors by Polar Plot Methodology
Critchley, L. A. H., Yang, X. X., & Lee, A. S. Y. (2011) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2011.01.003 · Cited by 248 · cited 1×
“9 10 Evaluation of the trend in CO might be helpful to evaluate the ef-fectsofinterventionsandisintuitive,becauseCOiscontinuously changingasaresultofavarietyofin fl uences,suchasrespiration, the autonomic nervous system, and changes in metabolic demand.”
Precision of the transpulmonary thermodilution measurements
Monnet, X., Persichini, R., Ktari, M., Jozwiak, M., Richard, C., & Teboul, J.-L. (2011) · Critical Care · doi:10.1186/cc10421 · Cited by 194
Saugel, B., Grothe, O., & Wagner, J. Y. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000725 · Cited by 163 · cited 1×
“limitations.(11) As an alternative, the concept of ‘clinical concordance’ and a corresponding error grid method for evaluation of trending ability from a clinical perspective is introduced.”
BackgroundNägele, P. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg087 · Cited by 116 · cited 2×
“The CI of the bias should not be confused with the LOA.”
Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation
Jansen, J. R. C., & Versprille, A. (1986) · Intensive Care Medicine · doi:10.1007/bf00254515 · Cited by 114 · cited 1×
“1 23 – 27 Both TDCO and TPCO can therefore be considered valuable as a reference technique, if properly performed.”
Self-citationHamilton, C., & Stamey, J. D. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9092-x · Cited by 72
A Hierarchical Outcomes Approach to Test Assessment
Pearl, W. S. (1999) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(99)70421-x · Cited by 46
Single Injection Thermodilution
Jansen, J. R. C., Schreuder, J. J., Settels, J. J., Kornet, L., Penn, O. C. K. M., Mulder, P. G. H., Versprille, A., & Wesseling, K. H. (1996) · Anesthesiology · doi:10.1097/00000542-199609000-00006 · Cited by 33
Self-citationHamilton, C., & Lewis, S. (2010) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-010-9230-8 · Cited by 24 · cited 1×
“Bland–Altman analysis without correction for paired measurements may underestimate the of the differences, leading to falsely narrow LOA and confidence intervals (CIs).(5) 6 12 14 As illustrated by Hamilton and Lewis,(5) this effect increaseswith a small number of subjects, large number of measurements per subject,…”
BackgroundMontenij, L. J., Bühre, W., de Jong, S. A., Harms, J. H., van Herwaarden, J. A., Kruitwagen, C. L. J. J., & de Waal, E. E. C. (2014) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000160 · Cited by 20 · cited 2×
“Discrepancy will therefore emerge during haemodynamic changes, which fade out in time.(20) The timing and recording of measurements is therefore important, and postponing measurements during acute haemodynamic changes should be considered.”
BackgroundSelf-citationBerthelsen, P. G., & Nilsson, L. B. (2006) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.01109.x · Cited by 16
Precision of transpulmonary thermodilution: how many measurements are necessary?
Gondos, T., Marjanek, Z., Kisvarga, Z., & Halász, G. (2009) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32832a2d23 · Cited by 16 · cited 1×
“1 23 – 27 Both TDCO and TPCO can therefore be considered valuable as a reference technique, if properly performed.”
Cited by
Reporting Standards for a Bland–Altman Agreement Analysis: A Review of Methodological Reviews
Gerke, O. (2020) · Diagnostics · doi:10.3390/diagnostics10050334 · Cited by 246
Metadata
- Authors
- Montenij, L. J., Buhre, W. F., Jansen, J. R., Kruitwagen, C. L., & de Waal, E. E.
- Venue
- British Journal of Anaesthesia
- Publisher
- Elsevier BV
- Published
- 2016-06
- Volume
- 116
- Issue
- 6
- Pages
- 750-758
- ISSN
- 0007-0912 (ISSN-L)
- OpenAlex
- W2401951079
- Cited by
- 165
- References
- 27
- FWCI
- 11.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.