Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Neurophysiological effects of stimulation through electrodes in the human subthalamic nucleus

Ashby, P., Kim, Y. J., Kumar, R., Lang, A. E., Lozano, A. M.·1999·Brain

Abstract

The effects of stimulation through macroelectrodes implanted in the subthalamic nucleus (STN) were studied in 14 patients with parkinsonism. Single stimuli delivered directly to the STN electrodes with an external stimulator modulated voluntary electromyography (EMG) of contralateral muscles in most patients. A short-latency facilitation ('peak') was attributed to the activation of the corticospinal system. A longer latency inhibition ('dip'), often preceded or followed by facilitations, appeared to arise from the activation of large-diameter fibres running parallel to the electrode and to be transmitted through the motor cortex. It is possible that the dip could result from the inhibition of thalamocortical neurons. With high-frequency stimulation ( approximately 100 Hz) the peaks occurred at the stimulus frequency; the dips became confluent and outlasted the duration of the stimulus train. There was no evidence that high-frequency stimulation produced 'blocking'. The studies were repeated in 12 patients a mean of 5.8 months after implantation of the stimulator. The same short-latency effects were obtained. They were present on 7 out of 23 sides at the settings in use and on the majority of sides if the stimulus intensity was slightly increased. There was no clear relationship between these short-latency effects and the patients' overall clinical improvement; the effects may result from the spread of current to large-fibre systems near the STN. In five patients, high-frequency stimulation on one side immediately reduced tremor in the contralateral limbs. This effect arose from the activation of large-diameter fibres and, like the dip, had about the same threshold at each of the contacts. Frequencies as low as 70 Hz were sufficient. We conclude that the control of tremor by STN stimulation is due to the activation of a large-fibre system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/brain/122.10.1919

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 162

Metadata

Authors
Ashby, P., Kim, Y. J., Kumar, R., Lang, A. E., & Lozano, A. M.
Venue
Brain
Published
1999-10
Volume
122
Issue
10
Pages
1919-1931
ISSN
  • 0006-8950 (ISSN-L)
  • 1460-2156
OpenAlex
W1987007963
Cited by
162
References
2
FWCI
6.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neurophysiological effects of stimulation through electrodes in the human subthalamic nucleus. https://app.cochat.ai/papers/10.1093/brain/122.10.1919
The paper
Ashby, P., Kim, Y. J., Kumar, R., Lang, A. E., & Lozano, A. M. (1999). Neurophysiological effects of stimulation through electrodes in the human subthalamic nucleus. Brain. https://doi.org/10.1093/brain/122.10.1919

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.