The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Identifying the ischaemic penumbra using pH-weighted magnetic resonance imaging
Open accessAbstract
The original concept of the ischaemic penumbra suggested imaging of regional cerebral blood flow and metabolism would be required to identify tissue that may benefit from intervention. Amide proton transfer magnetic resonance imaging, a chemical exchange saturation transfer technique, has been used to derive cerebral intracellular pH in preclinical stroke models and has been proposed as a metabolic marker of ischaemic penumbra. In this proof of principle clinical study, we explored the potential of this pH-weighted magnetic resonance imaging technique at tissue-level. Detailed voxel-wise analysis was performed on data from a prospective cohort of 12 patients with acute ischaemic stroke. Voxels within ischaemic core had a more severe intracellular acidosis than hypoperfused tissue recruited to the final infarct (P < 0.0001), which in turn was more acidotic than hypoperfused tissue that survived (P < 0.0001). In addition, when confined to the grey matter perfusion deficit, intracellular pH (P < 0.0001), but not cerebral blood flow (P = 0.31), differed between tissue that infarcted and tissue that survived. Within the presenting apparent diffusion coefficient lesion, intracellular pH differed between tissue with early apparent diffusion lesion pseudonormalization and tissue with true radiographic recovery. These findings support the need for further investigation of pH-weighted imaging in patients with acute ischaemic stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Thresholds in cerebral ischemia - the ischemic penumbra.
Astrup, J., Siesjö, B. K., & Symon, L. (1981) · Stroke · doi:10.1161/01.str.12.6.723 · Cited by 2,820
Viability thresholds and the penumbra of focal ischemia
Hossmann, K. (1994) · Annals of Neurology · doi:10.1002/ana.410360404 · Cited by 1,370
Cited by
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Clinical applications of chemical exchange saturation transfer (CEST) MRI
Jones, K. M., Pollard, A. C., & Pagel, M. D. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25838 · Cited by 287
Noninvasive Detection of Extracellular pH in Human Benign and Malignant Liver Tumors Using CEST MRI
Tang, Y., Xiao, G., Shen, Z., Zhuang, C., Xie, Y., Zhang, X., Yang, Z., Guan, J., Shen, Y., Chen, Y., et al. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.578985 · Cited by 56
Metadata
- Authors
- Harston, G. W. J., Tee, Y. K., Blockley, N., Okell, T. W., Thandeswaran, S., Shaya, G., Sheerin, F., Cellerini, M., Payne, S., Jezzard, P., Chappell, M., & Kennedy, J.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-12-29
- Volume
- 138
- Issue
- 1
- Pages
- 36-42
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2127176859
- Cited by
- 166
- References
- 3
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identifying the ischaemic penumbra using pH-weighted magnetic resonance imaging. https://app.cochat.ai/papers/10.1093/brain/awu374
- The paper
- Harston, G. W. J., Tee, Y. K., Blockley, N., Okell, T. W., Thandeswaran, S., Shaya, G., Sheerin, F., Cellerini, M., Payne, S., Jezzard, P., Chappell, M., & Kennedy, J. (2015). Identifying the ischaemic penumbra using pH-weighted magnetic resonance imaging. Brain. https://doi.org/10.1093/brain/awu374
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.