Crowdsourcing seizure detection: algorithm development and validation on human implanted device recordings
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
There exist significant clinical and basic research needs for accurate, automated seizure detection algorithms. These algorithms have translational potential in responsive neurostimulation devices and in automatic parsing of continuous intracranial electroencephalography data. An important barrier to developing accurate, validated algorithms for seizure detection is limited access to high-quality, expertly annotated seizure data from prolonged recordings. To overcome this, we hosted a kaggle.com competition to crowdsource the development of seizure detection algorithms using intracranial electroencephalography from canines and humans with epilepsy. The top three performing algorithms from the contest were then validated on out-of-sample patient data including standard clinical data and continuous ambulatory human data obtained over several years using the implantable NeuroVista seizure advisory system. Two hundred teams of data scientists from all over the world participated in the kaggle.com competition. The top performing teams submitted highly accurate algorithms with consistent performance in the out-of-sample validation study. The performance of these seizure detection algorithms, achieved using freely available code and data, sets a new reproducible benchmark for personalized seizure detection. We have also shared a 'plug and play' pipeline to allow other researchers to easily use these algorithms on their own datasets. The success of this competition demonstrates how sharing code and high quality data results in the creation of powerful translational tools with significant potential to impact patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geurts, P., Ernst, D., & Wehenkel, L. (2006) · Machine Learning · doi:10.1007/s10994-006-6226-1 · Cited by 9,300
Early Identification of Refractory Epilepsy
Kwan, P., & Brodie, M. J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002033420503 · Cited by 5,204
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282
Seizure detection, seizure prediction, and closed-loop warning systems in epilepsy
Ramgopal, S., Thome-Souza, S., Jackson, M., Kadish, N. E., Sánchez Fernández, I., Klehm, J., Bosl, W., Reinsberger, C., Schachter, S., & Loddenkemper, T. (2014) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2014.06.023 · Cited by 469
Bagging, Boosting and Ensemble Methods
Bühlmann, P. (2012) · Handbook of Computational Statistics · doi:10.1007/978-3-642-21551-3_33 · Cited by 375
EEG-based neonatal seizure detection with Support Vector Machines
Temko, A., Thomas, E., Marnane, W., Lightbody, G., & Boylan, G. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.06.034 · Cited by 339
Dudek, F. E., & Staley, K. J. (2011) · Epilepsy Research · doi:10.1016/j.eplepsyres.2011.10.017 · Cited by 20
Cited by
Diagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403
Emami, A., Kunii, N., Matsuo, T., Shinozaki, T., Kawai, K., & Takahashi, H. (2019) · NeuroImage: Clinical · doi:10.1016/j.nicl.2019.101684 · Cited by 160
“A number of EEG signal features have been considered to represent seizures (Ahmedt-Aristizabal et al., 2017; Baldassano et al., 2017; Orosco et al., 2013; Venkataraman et al., 2014); e.”
Automatic seizure detection using three-dimensional CNN based on multi-channel EEG
Wei, X., Zhou, L., Chen, Z., Zhang, L., & Zhou, Y. (2018) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-018-0693-8 · Cited by 159
“A recent competition on Kaggle held the seizure detection contest, the top three winner algorithms [44] includes the hand – engineered and deep learning methods, but they relied on complex features selected.”
MethodMachine learning and wearable devices of the future
Beniczky, S., Karoly, P., Nurse, E., Ryvlin, P., & Cook, M. (2021) · Epilepsia · doi:10.1111/epi.16555 · Cited by 155
Self-citationNon-invasive wearable seizure detection using long–short-term memory networks with transfer learning
Nasseri, M., Pal Attia, T., Joseph, B., Gregg, N. M., Nurse, E. S., Viana, P. F., Schulze-Bonhage, A., Dümpelmann, M., Worrell, G., Freestone, D. R., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abef8a · Cited by 66
Self-citation
Metadata
- Authors
- Baldassano, S. N., Brinkmann, B. H., Ung, H., Blevins, T., Conrad, E. C., Leyde, K., Cook, M. J., Khambhati, A. N., Wagenaar, J. B., Worrell, G. A., & Litt, B.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-04-27
- Volume
- 140
- Issue
- 6
- Pages
- 1680-1691
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2607894559
- Cited by
- 113
- References
- 7
- FWCI
- 7.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.