Effects of Neural Synchrony on Surface EEG
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
It has long been assumed that the surface electroencephalography (EEG) signal depends on both the amplitude and spatial synchronization of underlying neural activity, though isolating their respective contribution remains elusive. To address this, we made simultaneous surface EEG measurements along with intracortical recordings of local field potentials (LFPs) in the primary visual cortex of behaving nonhuman primates. We found that trial-by-trial fluctuations in EEG power could be explained by a linear combination of LFP power and interelectrode temporal synchrony. This effect was observed in both stimulus and stimulus-free conditions and was particularly strong in the gamma range (30-100 Hz). Subsequently, we used pharmacological manipulations to show that neural synchrony can produce a positively modulated EEG signal even when the LFP signal is negatively modulated. Taken together, our results demonstrate that neural synchrony can modulate EEG signals independently of amplitude changes in neural activity. This finding has strong implications for the interpretation of EEG in basic and clinical research, and helps reconcile EEG response discrepancies observed in different modalities (e.g., EEG vs. functional magnetic resonance imaging) and different spatial scales (e.g., EEG vs. intracranial EEG).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Neuronal Oscillations in Cortical Networks
Buzsáki, G., & Draguhn, A. (2004) · Science · doi:10.1126/science.1099745 · Cited by 6,576
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
Dynamic Brain Sources of Visual Evoked Responses
Makeig, S., Westerfield, M., Jung, T.-P., Enghoff, S., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2002) · Science · doi:10.1126/science.1066168 · Cited by 1,630
Different Origins of Gamma Rhythm and High-Gamma Activity in Macaque Visual Cortex
Ray, S., & Maunsell, J. H. R. (2011) · PLoS Biology · doi:10.1371/journal.pbio.1000610 · Cited by 1,012
Neuronal Mechanisms and Attentional Modulation of Corticothalamic Alpha Oscillations
Bollimunta, A., Mo, J., Schroeder, C. E., & Ding, M. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.5580-10.2011 · Cited by 441
Propofol Anesthesia and Sleep: A High-Density EEG Study
Murphy, M., Bruno, M.-A., Riedner, B. A., Boveroux, P., Noirhomme, Q., Landsness, E. C., Brichant, J.-F., Phillips, C., Massimini, M., Laureys, S., et al. (2011) · Sleep · doi:10.1093/sleep/34.3.283 · Cited by 418
Murakami, S., & Okada, Y. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.105379 · Cited by 395
Nunez, P. L., & Silberstein, R. B. (2000) · Brain Topography · doi:10.1023/a:1026683200895 · Cited by 307
Maier (2010) · Frontiers in System Neuroscience · doi:10.3389/fnsys.2010.00031 · Cited by 266
Infragranular sources of sustained local field potential responses in macaque primary visual cortex
Maier, A., Aura, C. J., & Leopold, D. A. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.5300-09.2011 · Cited by 99
Cited by
Closed-loop brain training: the science of neurofeedback
Sitaram, R., Ros, T., Stoeckel, L., Haller, S., Scharnowski, F., Lewis-Peacock, J., Weiskopf, N., Blefari, M. L., Rana, M., Oblak, E., et al. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2016.164 · Cited by 1,306
Where Does EEG Come From and What Does It Mean?
Cohen, M. X. (2017) · Trends in Neurosciences · doi:10.1016/j.tins.2017.02.004 · Cited by 722
Theta Oscillations in Human Memory
Herweg, N. A., Solomon, E. A., & Kahana, M. J. (2020) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2019.12.006 · Cited by 550
The roles of cortical oscillations in sustained attention
Clayton, M. S., Yeung, N., & Cohen Kadosh, R. (2015) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2015.02.004 · Cited by 533
Wearable, Wireless EEG Solutions in Daily Life Applications: What are we Missing?
Mihajlovic, V., Grundlehner, B., Vullers, R., & Penders, J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328317 · Cited by 289
Metadata
- Authors
- Musall, S., von Pföstl, V., Rauch, A., Logothetis, N. K., & Whittingstall, K.
- Venue
- Cerebral Cortex
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-12-12
- Volume
- 24
- Issue
- 4
- Pages
- 1045-1053
- ISSN
- 1047-3211 (ISSN-L)
- 1460-2199
- OpenAlex
- W2144112898
- Cited by
- 123
- References
- 12
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.