The DOI matches its Crossref record.
Comprehensive Two-Dimensional Gas Chromatography using an On-Column Thermal Modulator Interface
Abstract
A thermal desorption modulator prepared on an open-tubular gas chromatographic column continuously generates fast chromatograms sampled from a flowing stream. The output from a slower chromatographic column is a suitable sample stream. Taking the output from one gas chromatographic column as input to a second column through a thermal modulator then generates a set of high-speed chromatograms. One such secondary chromatogram is generated at each point in the primary chromatogram. When plotted in an appropriate two-dimensional form, this set of high-speed chromatograms becomes a comprehensive two-dimensional gas chromatogram. A sample first separated by one column is separated a second time by an independent column. All substances in the sample mixture pass through both columns. Two retention time measures characterize each sample substance. Each substance forms a peak on the two-dimensional plane at a location determined by the interaction of the substance with the two different stationary phases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
Hajšlová, J., & Zrostlı́ková, J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00539-9 · Cited by 441
Phillips, J. B., & Beens, J. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00815-8 · Cited by 403
Self-citationAnalytical and statistical approaches to metabolomics research
Issaq, H. J., Van, Q. N., Waybright, T. J., Muschik, G. M., & Veenstra, T. D. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900152 · Cited by 227
A New Dimension in Separation Science: Comprehensive Two‐Dimensional Gas Chromatography
Meinert, C., & Meierhenrich, U. J. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200842 · Cited by 106
Myrgorodska, I., Meinert, C., Martins, Z., le Sergeant d’Hendecourt, L., & Meierhenrich, U. J. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.01.014 · Cited by 44
Metadata
- Authors
- Liu, Z., & Phillips, J. B.
- Venue
- Journal of Chromatographic Science
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-06-01
- Volume
- 29
- Issue
- 6
- Pages
- 227-231
- ISSN
- 0021-9665 (ISSN-L)
- 1945-239X
- OpenAlex
- W2333011007
- Cited by
- 798
- References
- 0
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comprehensive Two-Dimensional Gas Chromatography using an On-Column Thermal Modulator Interface. https://app.cochat.ai/papers/10.1093/chromsci/29.6.227
- The paper
- Liu, Z., & Phillips, J. B. (1991). Comprehensive Two-Dimensional Gas Chromatography using an On-Column Thermal Modulator Interface. Journal of Chromatographic Science. https://doi.org/10.1093/chromsci/29.6.227
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.