Kinetic Model of Supercritical Fluid Extraction
The DOI matches its Crossref record.
Abstract
A comprehensive mathematical model was developed for a packed-tube extractor geometry that can be used to predict removal efficiency versus extraction time for supercritical fluid extraction (SFE) if the same matrix parameters and extraction conditions are known. The model is based on well-established theoretical relationships describing mass transfer kinetics, the chromatographic elution process, and the convolution theorem. The model considers several factors that could potentially contribute to slow extraction rates, including kinetics of desorption, swelling, diffusion of analyte in the organic component of the porous matrix, and fluid/matrix distribution constants. The method can be applied to model both dynamic and static/dynamic SFE techniques, and can be used to investigate analyte-matrix interaction to determine the extraction-rate limiting process. This information can then be used to predict optimum extraction conditions for different types of samples. The model can be extended to predict extraction rates when other types of fluids (gas or liquid) are used to elute analytes from the packed-tube extractor. A fully optimized extraction method based on a packed tube should consider different types of flowing media (supercritical fluid, liquid, gas, or mixtures) to minimize time and cost of sample preparation procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioprocess engineering of microalgae to produce a variety of consumer products
Harun, R., Singh, M., Forde, G. M., & Danquah, M. K. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2009.11.004 · Cited by 1,009
Commercialization potential of microalgae for biofuels production
Singh, J., & Gu, S. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.06.014 · Cited by 1,001
Evolution of solid-phase microextraction technology
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00535-5 · Cited by 787
Self-citationSolid-Phase Microextraction. A Solvent-Free Alternative for Sample Preparation
Zhang, Z., Yang, M. J., & Pawliszyn, J. (1994) · Analytical Chemistry · doi:10.1021/ac00089a001 · Cited by 763
Self-citationEnzyme assisted extraction of biomolecules as an approach to novel extraction technology: A review
Nadar, S. S., Rao, P., & Rathod, V. K. (2018) · Food Research International · doi:10.1016/j.foodres.2018.03.006 · Cited by 696
Automated In-Tube Solid-Phase Microextraction Coupled to High-Performance Liquid Chromatography
Eisert, R., & Pawliszyn, J. (1997) · Analytical Chemistry · doi:10.1021/ac970319a · Cited by 547
Self-citationDevelopments in oil extraction from microalgae
Mercer, P., & Armenta, R. E. (2011) · European Journal of Lipid Science and Technology · doi:10.1002/ejlt.201000455 · Cited by 532
Extraction of Organic Pollutants from Environmental Solids with Sub- and Supercritical Water
Hawthorne, S. B., Yang, Y., & Miller, D. J. (1994) · Analytical Chemistry · doi:10.1021/ac00090a019 · Cited by 474
Ramos, L., Kristenson, E. M., & Brinkman, U. A. T. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01336-5 · Cited by 415
Camel, V. (2001) · The Analyst · doi:10.1039/b008243k · Cited by 347
Sample Preparation: Quo Vadis?
Pawliszyn, J. (2003) · Analytical Chemistry · doi:10.1021/ac034094h · Cited by 287
Self-citationLangenfeld, J. J., Hawthorne, S. B., Miller, D. J., & Pawliszyn, J. (1993) · Analytical Chemistry · doi:10.1021/ac00052a006 · Cited by 280
Self-citationPressurised liquid extraction of persistent organic pollutants in environmental analysis
Björklund, E., Nilsson, T., & Bøwadt, S. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00002-9 · Cited by 252
Metadata
- Authors
- Pawliszyn, J.
- Venue
- Journal of Chromatographic Science
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-01-01
- Volume
- 31
- Issue
- 1
- Pages
- 31-37
- ISSN
- 0021-9665 (ISSN-L)
- 1945-239X
- OpenAlex
- W2327557023
- Cited by
- 135
- References
- 0
- FWCI
- 14.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.