Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 415

The DOI matches its Crossref record.

Direct Spectrophotometric Determination of Albumin in Human Serum

Rodkey, F Lee·1965·Clinical Chemistry

Abstract

In a convenient and direct method for determination of albumin in human serum, based on the decrease in absorbance of a neutral buffered solution of bromcresol green when albumin combines with the indicator, serum is diluted with a solution of bromcresol green of sufficient concentration to allow essentially linear change of absorbance with albumin concentration. Measurements are made at 615 mµ, where the absorbance of hemoglobin or bilirubin does not interfere. Extremely lipemic, turbid serums may be accurately analyzed. This method has been applied to a number of abnormal serums and compared with measurements of the albumin fraction of serum which is soluble in 2% (w/v) TCA in ethanol. Satisfactory agreement was obtained. Tests indicated that bromcresol green was not bound by serum globulins.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/11.4.478

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 415

Metadata

Authors
Rodkey, F. L.
Venue
Clinical Chemistry
Published
1965-04-01
Volume
11
Issue
4
Pages
478-487
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1922526566
Cited by
415
References
0
FWCI
0.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct Spectrophotometric Determination of Albumin in Human Serum. https://app.cochat.ai/papers/10.1093/clinchem/11.4.478
The paper
Rodkey, F. L. (1965). Direct Spectrophotometric Determination of Albumin in Human Serum. Clinical Chemistry. https://doi.org/10.1093/clinchem/11.4.478

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.