A rate nephelometer for measuring specific proteins by immunoprecipitin reactions.
The DOI matches its Crossref record.
Abstract
A kinetic nephelometric method and instrument have been developed for the rapid determination of specific serum proteins by means of immunoprecipitin reactions. The maximum rate of change of scattered light intensity in an antigen-antibody reaction can be made to occur within 60 s after initiation of the reaction and provides a measure of the antigen concentration under antibody excess conditions. A mathematical relationship has been found for the conversion of the nonlinear maximum rate data directly into a linear concentration read-out, making possible the use of single-point calibration. Instrument operating parameters and computations are programmed for a particular analysis by means of machine-readable cards. Antigen-excess samples are detected rapidly by injection of calibrator into the reaction mixture after the rate signal has dropped to a pre-selected level. The method correlates well with both radial immunodiffusion and end-point nephelometric methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
McVeigh, G. E., Brennan, G. M., Johnston, G. D., McDermott, B. J., McGrath, L. T., Henry, W. R., Andrews, J. W., & Hayes, J. R. (1992) · Diabetologia · doi:10.1007/bf00429099 · Cited by 916
SERUM C‐REACTIVE PROTEIN LEVELS IN DISEASE*
Morley, J. J., & Kushner, I. (1982) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1982.tb22153.x · Cited by 421
Silverman, E. K., & Sandhaus, R. A. (2009) · New England Journal of Medicine · doi:10.1056/nejmcp0900449 · Cited by 416
Bovine immunoglobulins: An augmented review
Butler, J. E. (1983) · Veterinary Immunology and Immunopathology · doi:10.1016/0165-2427(83)90056-9 · Cited by 397
C-reactive protein as an outcome predictor for maintenance hemodialysis patients
Owen, W. F. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.00032.x · Cited by 378
Snowdon, D. A., Tully, C. L., Smith, C. D., Riley, K. P., & Markesbery, W. R. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/71.4.993 · Cited by 276
Human glandular salivas: their separate collection and analysis
Veerman, E. C. I., van den Keybus, P. A. M., Vissink, A., & Amerongen, A. V. N. (1996) · European Journal of Oral Sciences · doi:10.1111/j.1600-0722.1996.tb00090.x · Cited by 253
Clemmons, D., Underwood, L., Dickerson, R., Brown, R., Hak, L., MacPhee, R., & Heizer, W. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.2.191 · Cited by 211
Sabaté, J., Haddad, E., Tanzman, J. S., Jambazian, P., & Rajaram, S. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.6.1379 · Cited by 184
Association of serum C3 levels with the risk of myocardial infarction
Muscari, A., Bozzoli, C., Puddu, G. M., Sangiorgi, Z., Dormi, A., Rovinetti, C., Descovich, G. C., & Puddu, P. (1995) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)80314-3 · Cited by 183
Metadata
- Authors
- Sternberg, J. C.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1977-08-01
- Volume
- 23
- Issue
- 8
- Pages
- 1456-1464
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1910266304
- Cited by
- 301
- References
- 0
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.