CoChat

Simultaneous determination of retinol and retinyl esters in serum or plasma by reversed-phase high-performance liquid chromatography.

DeRuyter, M G, De Leenheer, A P · 1978 · Clinical Chemistry
Cited by 106

The DOI matches its Crossref record.

Abstract

We propose a single-run liquid-chromatographic determination, with ultraviolet detection at 330 nm, for serum retinol and retinyl esters. The vitamin A derivatives are extracted according to the Bligh-Dyer procedure. With 200 microliter or serum, the lower detection limit is 50 microgram/liter for retinol and about 100 microgram/liter for retinyl esters. Within-run precision (CV) was 2.3% for retinol, 4.3% for retinyl palmitate. Day-to-day percision (CV, n = 20) for retinol was 4.9% during a month. The method can be used for the assessment of vitamin A absorption tests and for the determination of serum retinol (normal, subnormal, and above-normal concentrations). Serum retinyl esters can only be measured in conditions where concentrations exceed 100 microgram/liter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/24.11.1920

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 106

Metadata

Authors
DeRuyter, M. G., & De Leenheer, A. P.
Venue
Clinical Chemistry
Published
1978-11-01
Volume
24
Issue
11
Pages
1920-1923
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2228000409
Cited by
106
References
0
FWCI
0.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous determination of retinol and retinyl esters in serum or plasma by reversed-phase high-performance liquid chromatography. https://app.cochat.ai/papers/10.1093/clinchem/24.11.1920
The paper
DeRuyter, M. G., & De Leenheer, A. P. (1978). Simultaneous determination of retinol and retinyl esters in serum or plasma by reversed-phase high-performance liquid chromatography. Clinical Chemistry. https://doi.org/10.1093/clinchem/24.11.1920

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.