The DOI matches its Crossref record.
Comparison of double- and single-isotope enzymatic derivative methods for measuring catecholamines in human plasma.
Abstract
We directly compared the reliability of a single-isotope enzymatic derivative technique for measurement of plasma catecholamines with that of the well-established double-isotope method. A significant (p less than 0.001) correlation was observed between measurements (n = 52) in the two assays, both for norepinephrine (r = 0.97) and epinephrine (r = 0.80). Means and coefficients of variation for the two analytes in a pooled specimen of plasma, measured repeatedly during six months, were virtually identical by each assay method. Basal plasma catecholamine concentrations in two different groups of apparently healthy subjects were also similar by each method. Dopamine concentrations in plasma were consistently below the limits measurable by either technique. The single-isotope assay requires half the assay time and 1/200th the sample as the double-isotope method. We conclude that this assay is just as reliable as the double-isotope technique and gives virtually identical values for norepinephrine and epinephrine concentrations in the physiological range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diminished B cell secretory capacity in patients with noninsulin-dependent diabetes mellitus
Ward, W. K., Bolgiano, D. C., McKnight, B., Halter, J. B., & Porte, D. (1984) · Journal of Clinical Investigation · doi:10.1172/jci111542 · Cited by 483
Self-citationDifferential changes of autonomic nervous system function with age in man
Pfeifer, M. A., Weinberg, C. R., Cook, D., Best, J. D., Reenan, A., & Halter, J. B. (1983) · The American Journal of Medicine · doi:10.1016/0002-9343(83)91201-9 · Cited by 457
Self-citationBody Fat and the Activity of the Autonomic Nervous System
Peterson, H. R., Rothschild, M., Weinberg, C. R., Fell, R. D., McLeish, K. R., & Pfeifer, M. A. (1988) · New England Journal of Medicine · doi:10.1056/nejm198804283181701 · Cited by 411
The eating paradox: How we tolerate food.
Woods, S. C. (1991) · Psychological Review · doi:10.1037//0033-295x.98.4.488 · Cited by 337
The effect of intensive endurance exercise training on body fat distribution in young and older men
Schwartz, R. S., Shuman, W. P., Larson, V., Cain, K. C., Fellingham, G. W., Beard, J. C., Kahn, S. E., Stratton, J. R., Cerqueira, M. D., & Abrass, I. B. (1991) · Metabolism · doi:10.1016/0026-0495(91)90239-s · Cited by 275
Metadata
- Authors
- Evans, M. I., Halter, J. B., & Porte, D.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1978-04-01
- Volume
- 24
- Issue
- 4
- Pages
- 567-570
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1895952682
- Cited by
- 180
- References
- 0
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of double- and single-isotope enzymatic derivative methods for measuring catecholamines in human plasma. https://app.cochat.ai/papers/10.1093/clinchem/24.4.567
- The paper
- Evans, M. I., Halter, J. B., & Porte, D. (1978). Comparison of double- and single-isotope enzymatic derivative methods for measuring catecholamines in human plasma. Clinical Chemistry. https://doi.org/10.1093/clinchem/24.4.567
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.