The DOI matches its OpenAlex record.
Use of 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone chromogenic system in direct enzymic assay of uric acid in serum and urine.
Abstract
A new direct colorimetric procedure for uric acid assay in serum or urine is described, utilizing a 3,5-dichloro-2-hydroxybenzene sulfonic acid/4-aminophenazone chromogenic system in the presence of horseradish peroxidase and uricase from Aspergillus flavus. This chromogen system has a high absorptivity, affording useful results with sample/reagent volume ratios as low as 0.025. The procedure is applicable to serum, plasma, or diluted urine. A single working reagent is used; the reaction is complete in less than 15 min at room temperature. The red dye formed is measured at 520 nm; a blank sample measurement is not needed. The standard curve for the method is linear for uric acid concentrations up to 1500 mumol/L. Average analytical recovery of uric acid in human sera and urine exceeded 99%; within-run and between-run precision studies showed CV's of less than or equal to 1.2 and less than or equal to 2.2%, respectively. The new procedure correlated well with the uricase/catalase and uricase/ultraviolet methods. The method is suitable for automation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Segal, A. W., West, I., Wientjes, F., Nugent, J. H. A., Chavan, A. J., Haley, B., Garcia, R. C., Rosen, H., & Scrace, G. (1992) · Biochemical Journal · doi:10.1042/bj2840781 · Cited by 349
Nelson, S. K., Bose, S. K., Grunwald, G. K., Myhill, P., & McCord, J. M. (2006) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2005.08.043 · Cited by 215
Antioxidant response to oxidative stress induced by exhaustive exercise
Aguiló, A., Tauler, P., Fuentespina, E., Tur, J. A., Córdova, A., & Pons, A. (2005) · Physiology & Behavior · doi:10.1016/j.physbeh.2004.07.034 · Cited by 207
Plasma uric acid and the risk of type 2 diabetes in a Chinese community
Chien, K.-L., Chen, M.-F., Hsu, H.-C., Chang, W.-T., Su, T.-C., Lee, Y.-T., & Hu, F. B. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.095190 · Cited by 172
Ibrahim, Y. F., Moussa, R. A., Bayoumi, A. M. A., & Ahmed, A.-S. F. (2020) · Inflammopharmacology · doi:10.1007/s10787-019-00628-y · Cited by 75
Metadata
- Authors
- Fossati, P., Prencipe, L., & Berti, G.
- Venue
- Clinical Chemistry
- Publisher
- American Association for Clinical Chemistry
- Published
- 1980-02-01
- Volume
- 26
- Issue
- 2
- Pages
- 227-231
- ISSN
- 0009-9147 (ISSN-L)
- OpenAlex
- W2162043836
- Cited by
- 1,104
- References
- 0
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone chromogenic system in direct enzymic assay of uric acid in serum and urine. https://app.cochat.ai/papers/10.1093/clinchem/26.2.0227
- The paper
- Fossati, P., Prencipe, L., & Berti, G. (1980). Use of 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone chromogenic system in direct enzymic assay of uric acid in serum and urine. Clinical Chemistry. https://doi.org/10.1093/clinchem/26.2.0227
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.