CoChat

Anion-exchange chromatographic determination of bromide in serum.

Open access
Miller, M E, Cappon, C J · 1984 · Clinical Chemistry
Cited by 65

The DOI matches its Crossref record.

Abstract

In this liquid-chromatographic method for the determination of bromide in human serum, an important and unique feature is pre-analysis ultrafiltration of the sample, which effectively removes proteins. The chromatographic system consists of an anion-exchange column (Whatman Partisil SAX 10-micron particles), an isocratic phosphate-buffered mobile phase, and ultraviolet detection at 195 nm. The absolute detection limit, 0.6 ng of bromide, makes this method the most sensitive assay for serum bromide yet reported. The day-to-day CV ranged from 1.6% to 4.9%. Analytical recovery of bromide added to serum samples ranged from 96.2% to 108.8%. Data on bromide in serum are presented for adults and newborns and for adults given bromide orally.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/30.5.781

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Miller, M. E., & Cappon, C. J.
Venue
Clinical Chemistry
Published
1984-05-01
Volume
30
Issue
5
Pages
781-783
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W4302336172
Cited by
65
References
0
FWCI
0.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review